慢性血栓栓塞性肺动脉高压患者肺动脉涡流定量分析
本研究对28例慢性血栓栓塞性肺动脉高压患者在进行球囊肺动脉成形术前后行胸部4D-flow磁共振成像,测量肺动脉主干内反向血流的半高全宽、面积及容积流率以量化涡流持续时间;结果显示术后半高全宽、面积及容积流率均显著降低,且血压下降更明显的病例变化倾向更大,提示这些指标可用于无创评估球囊肺动脉成形术疗效。
要点
- 4D-flow磁共振可定量肺动脉主干内涡流,球囊肺动脉成形术后反向血流的半高全宽、面积及容积流率均显著降低。
- 球囊肺动脉成形术后血压下降更明显的病例,涡流指标下降幅度倾向更大。
- 半高全宽、面积和容积流率可能作为无创评估球囊肺动脉成形术疗效的指标。
核心结论
- 球囊肺动脉成形术促使肺动脉主干内反向血流的半高全宽、面积及容积流率显著降低,从而促进有效的血液输送;这些变化在球囊肺动脉成形术使压力下降更明显的病例中倾向更大;结果提示半高全宽、面积和容积流率是无创评估球囊肺动脉成形术疗效的有用指标。
研究设计与样本
- 对28例慢性血栓栓塞性肺动脉高压患者在球囊肺动脉成形术前后行胸部4D-flow磁共振成像,在肺动脉设置平面评估肺动脉主干内反向血流的容积流率、持续时间及面积,并测量容积流率时程峰值的半高全宽以量化涡流持续时间。
诊断标准与关键数值
- 半高全宽:球囊肺动脉成形术前1.88×10-1±1.51×10-2(心动周期)vs术后1.65×10-1±1.86×10-2(心动周期)。
- 面积比:球囊肺动脉成形术前2.67×10-1±1.30×10-2 vs术后2.38×10-1±1.31×10-2。
- 容积流率:球囊肺动脉成形术前13.6±2.21 mL/s vs术后11.3±2.36 mL/s。
临床应用与阅片要点
- 球囊肺动脉成形术前后整体血流模式似乎相同,但术后反向血流的半高全宽、面积和容积流率显著降低。
- 球囊肺动脉成形术使压力下降更明显的病例,这些涡流指标的变化倾向更大。
- 半高全宽、面积和容积流率可能是无创评估球囊肺动脉成形术疗效的有用指标。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study proposes an objective method of quantifying the vortex flow in pulmonary arteries to compare the duration of its presence before and after balloon pulmonary angioplasty (BPA) in patients with chronic thromboembolic pulmonary hypertension (CTEPH).
METHODS: Thoracic 4D-flow magnetic resonance imaging was performed in 28 CTEPH patients before and after BPA. Planes were set in pulmonary arteries to evaluate volume flow rate (VFR), the duration, and area of backward flow in the pulmonary trunk, which is a component of the vortex flow. The full width at half maximum (FWHM) of the peak of the time course of VFR of backward flow was assessed to quantify the duration of the vortical flow.
RESULTS: Although overall flow patterns after BPA appeared to be the same as the one before BPA, significant decreases in the FWHM, area, and VFR of the backward flow after BPA were found (FWHM: before, 1.88 × 10-1 ± 1.51 × 10-2 [cardiac cycle] vs. after, 1.65 × 10-1 ± 1.86 × 10-2 [cardiac cycle]; area ratio: before, 2.67 × 10-1 ± 1.30 × 10-2 vs. after, 2.38 × 10-1 ± 1.31 × 10-2; VFR: before, 13.6 ± 2.21 [mL/s] vs. after, 11.3 ± 2.36 [mL/s]).
CONCLUSION: BPA promoted significant decreases in the FWHM, area, and VFR of backward flow in the pulmonary trunk, thereby facilitating efficient blood transport. The tendencies for these changes were to be larger for cases where BPA more greatly decreased the pressure. The results suggest that the FWHM, area, and VFR are useful indicators for the noninvasive evaluation of the therapeutic effects of BPA.
引用
- Kamada, Ota, Nakamura, et al. Quantification of vortex flow in pulmonary arteries of patients with chronic thromboembolic pulmonary hypertension. Eur J Radiol. 2022. PMID: 35066341. doi:10.1016/j.ejrad.2021.110142
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。