速度选择性动脉自旋标记在脑胶质瘤灌注测量中的表现:与伪连续动脉自旋标记及动态磁敏感对比MRI的比较
回顾性纳入44例初诊胶质瘤患者,术前行VSASL、PCASL与DSC-PWI灌注MRI,视觉评分显示VSASL与DSC-PWI一致性(加权kappa 0.90)优于PCASL(0.68);VSASL-rTBF与DSC-PWI相关性(R²=80%)高于PCASL-rTBF(47%);VSASL在胶质瘤分级中诊断敏感度、特异度及准确率均优于PCASL。
要点
- 视觉评估中VSASL血流图与DSC-PWI一致性(加权kappa 0.90)优于PCASL(0.68)。
- VSASL-rTBF与DSC-PWI相关性(R²=80%)高于PCASL-rTBF(R²=47%)。
- VSASL在胶质瘤分级中的诊断敏感度、特异度及准确率优于PCASL。
核心结论
- VSASL在脑胶质瘤血流灌注定量方面显示出良好前景,可能提高ASL在术前胶质瘤分级中的诊断效能。
研究设计与样本
- 回顾性评估2017至2019年间44例连续初诊胶质瘤患者,术前均行包含VSASL、PCASL及DSC-PWI的灌注MRI。
关键影像表现/征象
- 基于1-5分标准视觉评估肿瘤相对于灰质的信号强度,VSASL血流图与DSC-PWI的成对一致性加权kappa为0.90,PCASL为0.68。
- VSASL-rTBF与DSC-PWI值的相关性(R²=80%)高于PCASL-rTBF(R²=47%),两者p均<0.001。
- ASL与DSC来源的rTBF均能良好区分低级别与高级别胶质瘤(p<0.001)。
诊断标准与关键数值
- 视觉评估采用1-5分评分标准评价肿瘤信号强度相对于灰质的水平。
- rTBF测量取血流图上肿瘤内热点的采样区,并对侧正常灰质血流进行归一化。
- VSASL在胶质瘤分级中的诊断敏感度、特异度及准确率优于PCASL。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the performance of velocity-selective (VS) ASL among patients with untreated gliomas by comparing with both pseudo-continuous (PC) ASL and dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI).
METHODS: Forty-four consecutive patients with newly diagnosed glioma who underwent preoperative perfusion MRI including VSASL, PCASL, and DSC-PWI between 2017 and 2019 were retrospectively evaluated. Visual inspection was performed to evaluate the tumor signal intensity relative to gray matter based on 1-5 score criteria and weighted kappa was used to evaluate the pair-wise concordance between VSASL or PCASL and DSC-PWI. The relative tumor blood flow (rTBF) was measured from sampling intra-tumoral areas of hot-spot on the blood flow map and normalized against the contralateral normal gray matter blood flow. Linear regression and Bland-Altman analyses were performed to evaluate the correlation and agreement of rTBF measurements between ASL methods and DSC-PWI. The ROC analysis was constructed to determine the diagnostic performance of three perfusion methods for grading gliomas.
RESULTS: TBF maps derived from VSASL were more comparable with DSC-PWI than PCASL on visual inspection (weighted kappa of 0.90 vs 0.68). In quantitative analysis, VSASL-rTBF yielded higher correlation with the values from DSC-PWI than PCASL-rTBF (R2 = 80% vs 47%, p < 0.001 for both). Both ASL and DSC-derived rTBF showed good distinction between low-grade and high-grade gliomas (p < 0.001). Compared to PCASL, VSASL yielded superior diagnostic sensitivity, specificity, and accuracy in glioma grading.
CONCLUSIONS: VSASL showed great promise for accurate quantification of TBF and could potentially improve the diagnostic performance of ASL in preoperative grading of gliomas.
KEY POINTS: • VSASL demonstrated a greater agreement with DSC-PWI than with PCASL on visual inspection and perfusion quantification. • VSASL showed a higher diagnostic sensitivity, negative predictive value, and accuracy than PCASL for glioma grading. • With the advantages of insensitivity to transit delay and no need of prescribing a labeling plane, VSASL could potentially improve the diagnostic performance of ASL for a more accurate, noninvasive quantification of TBF in patients with glioma.
引用
- Qu, Kong, Wen, et al. Perfusion measurement in brain gliomas using velocity-selective arterial spin labeling: comparison with pseudo-continuous arterial spin labeling and dynamic susceptibility contrast MRI. Eur Radiol. 2022. PMID: 35066634. doi:10.1007/s00330-021-08406-7