文献速递神经骨肌CTMR

电子密度双能CT与标准灰度CT及虚拟去钙图像检测颈椎间盘突出的诊断效能比较

Diagnostic performance of electron-density dual-energy CT in detection of cervical disc herniation in comparison with standard gray-scale CT and virtual non-calcium images.
PubMed 文献 · Eur Radiol · 2022-01-22

横断面研究纳入64例患者336个椎间盘,比较双能CT电子密度、标准CT和虚拟去钙图像对颈椎间盘突出的诊断效能,以3T MRI为参考标准。电子密度图像敏感度94%高于标准CT的76%和虚拟去钙图像的69%,特异度三组相似(90% vs 89% vs 90%)。结论认为电子密度重建可提高颈椎间盘突出的检出和诊断信心。

要点

  • 电子密度图像检测颈椎间盘突出敏感度94%,高于标准CT的76%和虚拟去钙图像的69%。
  • 三组图像特异度相似(90% vs 89% vs 90%),电子密度图像未牺牲特异度。
  • 电子密度图像可出现假阴性,尤其在T2W高信号椎间盘突出;下颈椎可显示假性椎间盘突出。

核心结论

  • 双能CT电子密度重建较标准CT和虚拟去钙图像可提高颈椎间盘突出的检出和诊断信心。

研究设计与样本

  • 横断面研究,纳入64例患者336个椎间盘(C2/3至C7/T1),2018年1月至2020年6月行双能CT光谱重建和3T MRI(间隔2周内),由4名放射科医师独立评估随机顺序的标准CT、虚拟去钙和电子密度图像,另2名有经验医师的MRI评估为参考标准。

关键影像表现/征象

  • 高材料密度的椎间盘在双能CT电子密度图像上显示良好。
  • 电子密度图像可出现假阴性结果,尤其对T2W图像上高信号的椎间盘突出。
  • 电子密度图像可在下颈椎显示假性椎间盘突出。

诊断标准与关键数值

  • 电子密度图像检测颈椎间盘突出敏感度94%(219/233;95% CI,90-97),标准CT 76%(177/233;70-81),虚拟去钙图像69%(160/233;62-76),P < 0.001。
  • 电子密度图像特异度90%(93/103;83-95),标准CT 89%(92/103;82-96),虚拟去钙图像90%(93/103;83-95),P > 0.05。
  • 4名读者间一致性:电子密度图像κ=0.558,标准CT κ=0.422,虚拟去钙图像κ=0.449,均为中等一致。

临床应用与阅片要点

  • 电子密度图像可提高颈椎间盘突出的检出敏感度,阅片时需注意T2W高信号椎间盘突出可能出现假阴性。
  • 下颈椎区域电子密度图像可显示假性椎间盘突出,判读时需结合其他序列或图像鉴别。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the diagnostic performance of dual-energy CT (DECT) with electron-density (ED) image reconstruction compared with standard CT (SC) and virtual non-calcium (VNCa) image CT reconstruction for detecting cervical disc herniation.

METHODS: This cross-sectional study was approved by the IRB. We enrolled 64 patients (336 intervertebral discs from C2/3 to C7/T1; mean age, 55 years; 17 women and 47 men) who underwent DECT with spectral reconstruction and 3-T MRI within 2 weeks between January 2018 and June 2020. Four radiologists independently evaluated the first image set of randomized SC, VNCa, and ED images to detect cervical disc herniation. After 8 weeks, the readers re-evaluated the second and the last image sets with an 8-week interval. MRI evaluations performed by two other experienced served as the reference standard. Comparing diagnostic performance between each images set was evaluated by a generalized estimating equation.

RESULTS: A total of 233 cervical disc herniations were noted on MRI. For detecting cervical disc herniation, electron-density images showed higher sensitivity (94% [219/233; 95% CI, 90-97] vs. 76% [177/233; 70-81] vs. 69% [160/233; 62-76]) (p < 0.001) and similar specificity (90% [93/103; 83-95] vs. 89% [92/103; 82-96] vs. 90% [93/103; 83-95]) (p > 0.05) as SC and VNCa images, respectively. Inter-reader agreement for cervical disc herniation calculated among the four readers was moderate for all image sets (κ = 0.558 for ED, κ = 0.422 for SC, and κ = 0.449 for VNCa).

CONCLUSION: DECT with ED reconstruction can improve cervical disc herniation detection and diagnostic confidence compared with SC and VNCa images.

KEY POINTS: • Intervertebral discs with high material density are well visualized on electron-density images obtained from dual-energy CT. • Electron-density images showed much higher sensitivity and diagnostic accuracy than standard CT and virtual non-calcium images for the detection of cervical disc herniation. • Electron-density images can have false-negative results, especially for disc herniation with high signal intensity on T2W images and can show pseudo-disc extrusion at the lower cervical spine.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Shim, Kim, Kang, et al. Diagnostic performance of electron-density dual-energy CT in detection of cervical disc herniation in comparison with standard gray-scale CT and virtual non-calcium images. Eur Radiol. 2022. PMID: 35064315. doi:10.1007/s00330-021-08374-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。