文献速递乳腺介入USMR

超声造影与磁共振成像评估乳腺癌微波消融疗效的比较

CEUS Versus MRI in Evaluation of the Effect of Microwave Ablation of Breast Cancer.
PubMed 文献 · Ultrasound Med Biol · 2022-01-19

本研究纳入2015至2019年26例接受超声引导下微波消融的乳腺癌患者,消融后3天内行超声造影和磁共振成像检查,以随访超过6个月的结果为参考,比较两种影像评估完全消融的诊断效能;结果显示超声造影和磁共振成像均能有效评估消融疗效,磁共振成像特异度和准确率略高。

要点

  • 消融后3天内超声造影和磁共振成像诊断完全消融的敏感度均为100%。
  • 磁共振成像诊断完全消融的特异度60%、准确率92.3%,超声造影分别为40%和88.5%。
  • 超声造影发现2例磁共振成像漏诊的残留肿瘤,磁共振成像发现3例超声造影漏诊的残留肿瘤。

核心结论

  • 消融后3天内,超声造影和磁共振成像均能有效评估乳腺癌微波消融的疗效。

研究设计与样本

  • 2015至2019年纳入26例乳腺癌患者,均行超声引导下微波消融,消融后3天内均行超声造影和磁共振成像检查,以随访超过6个月的结果为参考标准评估诊断效能。

诊断标准与关键数值

  • 超声造影诊断完全消融的敏感度100%、特异度40%、阳性预测值87.5%、阴性预测值100%、准确率88.5%。

临床应用与阅片要点

  • 若超声造影或磁共振成像任一显示消融区可疑强化,且超声引导下活检证实可疑区域有残留肿瘤,则补充微波消融。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Percutaneous microwave ablation (MWA) is a new minimally invasive technique for breast cancer treatment. The aim of this research was to compare the differences in performance between contrast-enhanced ultrasound (CEUS) and magnetic resonance imaging (MRI) with respect to the curative effect of MWA in the treatment of breast cancer. Between 2015 and 2019, 26 patients with breast cancer underwent ultrasound-guided MWA. All patients underwent both CEUS and MRI within 3 d after ablation. If either of the two imaging modalities revealed suspicious enhancement of the ablation zone and the ultrasound-guided biopsy confirmed residual tumor in the suspicious area, supplementary MWA was applied. The diagnostic efficacy of CEUS and MRI within 3 d after ablation was evaluated based on a >6-mo follow-up of 26 patients. Two cases were diagnosed with residual tumors by ultrasound that were missed by MRI. Three cases were diagnosed with residual tumors by MRI that were missed by CEUS. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of CEUS in the diagnosis of complete ablation were 100%, 40%, 87.5%, 100% and 88.5%, respectively. The sensitivity, specificity, PPV, NPV and accuracy of MRI in the diagnosis of complete ablation were 100%, 60%, 91.3%, 100% and 92.3%, respectively. Within 3 d, both CEUS and MRI can efficiently assess the efficacy of MWA of breast cancer.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Liu, Cai, Luo, et al. CEUS Versus MRI in Evaluation of the Effect of Microwave Ablation of Breast Cancer. Ultrasound Med Biol. 2022. PMID: 35063290. doi:10.1016/j.ultrasmedbio.2021.11.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。