1.5 T与3 T场强下MRI衍生肝脏表面结节性评分的个体内比较
纳入40例慢性肝病患者,在1.5 T和3 T场强下均行钆塞酸二钠增强MRI,用定量软件在肝胆期图像上计算左右肝叶的肝脏表面结节性(LSN)评分。结果示两种场强间及左右肝叶间LSN评分均存在显著差异,1.5 T与3 T间相关性很强(右叶rs=0.927,左叶rs=0.845),右叶与左叶间相关性弱;作者提示比较不同场强或不同肝叶来源的LSN评分时应谨慎。
要点
- 同一患者1.5 T与3 T的LSN评分相关性很强(右叶rs=0.927,左叶rs=0.845),但两场强间评分差异有统计学意义。
- 右叶与左叶LSN评分在1.5 T和3 T下均差异显著(1.5 T中位数1.201 vs 0.674;3 T为1.076 vs 0.592,均p<0.001)。
- 右叶与左叶LSN评分相关性弱(1.5 T rs=0.331,p=0.037;3 T rs=0.381,p=0.015)。
核心结论
- LSN评分在1.5 T与3 T之间以及右叶与左叶之间均存在显著差异,作者提示比较不同场强或不同肝叶来源的LSN评分时应谨慎,并认为需解决跨平台、跨肝叶的可重复性问题。
研究设计与样本
- 个体内比较研究,纳入40例慢性肝病患者,均行1.5 T和3 T钆塞酸二钠增强MRI,采用相同体素大小的轴位肝胆期图像,用定量软件计算左右肝叶LSN评分。
关键影像表现/征象
- 右叶与左叶LSN评分相关性弱:1.5 T rs=0.331(p=0.037),3 T rs=0.381(p=0.015)。
- 1.5 T与3 T的LSN评分相关性很强:右叶rs=0.927(p<0.001),左叶rs=0.845(p<0.001)。
- 右叶与左叶LSN评分差异显著:1.5 T中位数1.201 vs 0.674,3 T中位数1.076 vs 0.592(均p<0.001)。
- 1.5 T与3 T的LSN评分在左右肝叶均差异显著(均p<0.001)。
- Bland-Altman分析示1.5 T与3 T的系统偏倚右叶为0.08、左叶为0.07。
诊断标准与关键数值
- LSN评分由定量软件在钆塞酸二钠增强MRI肝胆期轴位图像上计算,1.5 T与3 T图像体素大小相同。
临床应用与阅片要点
- 作者提示比较不同场强或不同肝叶来源的LSN评分时应谨慎。
- 作者认为需解决跨平台、跨肝叶的可重复性问题,才能使用LSN评分;该评分操作相对简便,无需额外硬件或图像。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the MRI-derived liver surface nodularity (LSN) scores acquired on both 1.5 T and 3 T.
MATERIALS AND METHODS: Forty chronic liver disease patients who underwent gadoxetic acid-enhanced MRI at both 1.5 and 3 T were included. Axial hepatobiliary phase images with the same voxel size were used to calculate the LSN score in both liver lobes with a quantitative software. Rank correlation, Wilcoxon test, and Bland-Altman limits of agreement were used for statistical analysis.
RESULTS: There was a weak correlation between the right and left liver lobe on 1.5 T (rs = 0.331, p = 0.037) and 3 T (rs = 0.381, p = 0.015). The correlation between 1.5 T and 3 T on both liver lobes showed a very strong correlation (right, rs = 0.927, p < 0.001; left, rs = 0.845, p < 0.001). LSN scores differed significantly between both lobes on 1.5 T (median, 1.201 vs. 0.674, right vs. left) and 3 T (1.076 vs. 0.592) (all p < 0.001). LSN scores differed significantly between 1.5 T and 3 T on both lobes (all p < 0.001). The Bland-Altman plot comparing 1.5 T and 3 T on right and left liver lobes showed a systemic bias of 0.08 and 0.07, respectively.
CONCLUSIONS: LSN scores differed significantly on 1.5 T vs. 3 T and right vs. left liver lobe. Caution should be made when comparing LSN scores derived from different field strengths or the hepatic lobe. Interplatform, interlobar reproducibility should be resolved to use LSN scores, which is relatively easy to perform without additional hardware or images.
引用
- Jang, Song, Kim, et al. Intraindividual comparison of MRI-derived liver surface nodularity score at 1.5 T and 3 T. Abdom Radiol (NY). 2022. PMID: 35064351. doi:10.1007/s00261-022-03415-6