大责任斑块及更多颅内斑块与复发性卒中相关:基于血管壁成像的病例对照研究
回顾性纳入175例颅内动脉粥样硬化性缺血性卒中患者,比较初发组(n=100)与复发组(n=75)的高分辨率血管壁成像及DSC-PWI特征。复发组责任斑块体积更大(P=.006)、颅内斑块数更多(P<.001)、强化斑块更多(P=.003);调整后责任斑块体积(每增加10mm³ OR 1.16,95%CI 1.03-1.30,P=.015)和总斑块数(OR 1.31,95%CI 1.13-1.52,P<.001)与复发卒中独立相关,联合AUC升至0.71。
要点
- 复发卒中组责任斑块体积大于初发组(P=.006),颅内斑块数更多(P<.001)。
- 责任斑块体积每增加10mm³,复发卒中OR 1.16(95%CI 1.03-1.30,P=.015)。
- 全脑血管壁成像联合评估斑块体积与数目可能有助于识别复发高风险患者。
核心结论
- 大责任斑块和更多颅内斑块与复发性卒中独立相关。
研究设计与样本
- 回顾性病例对照研究,纳入175例颅内动脉粥样硬化性缺血性卒中患者(平均年龄59岁,SD 12;115例男性),行高分辨率血管壁成像和DSC-PWI,分为初发组(n=100)与复发组(n=75)。
关键影像表现/征象
- 复发组责任斑块体积大于初发组(P=.006)。
- 复发组颅内斑块数多于初发组(P<.001)。
- 复发组强化斑块数多于初发组(P=.003)。
诊断标准与关键数值
- 责任斑块体积每增加10mm³,复发卒中OR 1.16(95%CI 1.03-1.30,P=.015)。
- 总斑块数每增加1个,复发卒中OR 1.31(95%CI 1.13-1.52,P<.001)。
- 联合上述因素预测复发卒中的AUC为0.71。
临床应用与阅片要点
- 全脑血管壁成像可评估责任斑块体积、颅内斑块总数及强化斑块数,可能帮助识别复发卒中高风险患者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Intracranial atherosclerotic plaque features are potential factors associated with recurrent stroke, but previous studies only focused on a single lesion, and few studies investigated them with perfusion impairment. This study aimed to investigate the association among whole-brain plaque features, perfusion deficit, and stroke recurrence.
MATERIALS AND METHODS: Patients with ischemic stroke due to intracranial atherosclerosis were retrospectively collected and categorized into first-time and recurrent-stroke groups. Patients underwent high-resolution vessel wall imaging and DSC-PWI. Intracranial plaque number, culprit plaque features (such as plaque volume/burden, degree of stenosis, enhancement ratio), and perfusion deficit variables were recorded. Logistic regression analyses were performed to determine the independent factors associated with recurrent stroke.
RESULTS: One hundred seventy-five patients (mean age, 59 [SD, 12] years; 115 men) were included. Compared with the first-time stroke group (n = 100), the recurrent-stroke group (n = 75) had a larger culprit volume (P = .006) and showed more intracranial plaques (P < .001) and more enhanced plaques (P = .003). After we adjusted for other factors, culprit plaque volume (OR, 1.16 per 10-mm3 increase; 95% CI, 1.03-1.30; P = .015) and total plaque number (OR, 1.31; 95% CI, 1.13-1.52; P < .001) were independently associated with recurrent stroke. Combining these factors increased the area under the curve to 0.71.
CONCLUSIONS: Large culprit plaque and more intracranial plaques were independently associated with recurrent stroke. Performing whole-brain vessel wall imaging may help identify patients with a higher risk of recurrent stroke.
引用
- Wu, Wang, Zhao, et al. Large Culprit Plaque and More Intracranial Plaques Are Associated with Recurrent Stroke: A Case-Control Study Using Vessel Wall Imaging. AJNR Am J Neuroradiol. 2022. PMID: 35058299. doi:10.3174/ajnr.A7402
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。