文献速递乳腺乳腺X线

人工智能用于减少数字乳腺断层摄影乳腺癌筛查工作负荷

Artificial Intelligence for Reducing Workload in Breast Cancer Screening with Digital Breast Tomosynthesis.
PubMed 文献 · Radiology · 2022-01-18

该回顾性研究纳入两个医疗网络2013年6月至2018年11月的13306例数字乳腺断层摄影检查(9919名女性),模拟AI先过滤正常筛查、放射科医生仅判读剩余检查的工作流程。AI过滤使工作量减少39.6%,敏感度非劣(90.0% vs 90.8%,P=0.002),召回率降低25%(6.9% vs 9.2%,P=0.002)。读者研究中AI单独AUC高于平均读者(0.84 vs 0.81,P=0.002)。

要点

  • AI可识别无需放射科医生判读的正常数字乳腺断层摄影筛查检查,模拟流程中工作量减少39.6%。
  • AI过滤后敏感度非劣于放射科医生(90.0% vs 90.8%,P=0.002),召回率降低25%(6.9% vs 9.2%,P=0.002)。
  • 读者研究中AI单独AUC高于平均读者(0.84 vs 0.81,P=0.002)。

核心结论

  • AI模型能够识别正常的数字乳腺断层摄影筛查检查,在模拟临床工作流程中减少了需要放射科医生判读的检查数量。

研究设计与样本

  • 回顾性研究,纳入两个医疗网络2013年6月至2018年11月的13306例数字乳腺断层摄影检查(9919名女性),分为训练集3948名、验证集1661名和测试集4310名女性。

诊断标准与关键数值

  • 测试集4310名筛查女性(平均年龄60岁±11岁,5182例数字乳腺断层摄影检查)中,放射科医生检出459例癌症中的417例(90.8%),5182例检查中召回477例(9.2%)。
  • AI自动过滤后工作量为39.6%的减少,敏感度非劣(459例癌症中检出413例,90.0%,P=0.002),召回率降低25%(5182例检查中召回358例,6.9%,P=0.002)。
  • 读者研究(5名乳腺放射科医生判读205名女性的数字乳腺断层摄影图像)中,AI单独AUC为0.84,平均读者AUC为0.81(P=0.002)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Digital breast tomosynthesis (DBT) has higher diagnostic accuracy than digital mammography, but interpretation time is substantially longer. Artificial intelligence (AI) could improve reading efficiency. Purpose To evaluate the use of AI to reduce workload by filtering out normal DBT screens. Materials and Methods The retrospective study included 13 306 DBT examinations from 9919 women performed between June 2013 and November 2018 from two health care networks. The cohort was split into training, validation, and test sets (3948, 1661, and 4310 women, respectively). A workflow was simulated in which the AI model classified cancer-free examinations that could be dismissed from the screening worklist and used the original radiologists' interpretations on the rest of the worklist examinations. The AI system was also evaluated with a reader study of five breast radiologists reading the DBT mammograms of 205 women. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and recall rate were evaluated in both studies. Statistics were computed across 10 000 bootstrap samples to assess 95% CIs, noninferiority, and superiority tests. Results The model was tested on 4310 screened women (mean age, 60 years ± 11 [standard deviation]; 5182 DBT examinations). Compared with the radiologists' performance (417 of 459 detected cancers [90.8%], 477 recalls in 5182 examinations [9.2%]), the use of AI to automatically filter out cases would result in 39.6% less workload, noninferior sensitivity (413 of 459 detected cancers; 90.0%; P = .002), and 25% lower recall rate (358 recalls in 5182 examinations; 6.9%; P = .002). In the reader study, AUC was higher in the standalone AI compared with the mean reader (0.84 vs 0.81; P = .002). Conclusion The artificial intelligence model was able to identify normal digital breast tomosynthesis screening examinations, which decreased the number of examinations that required radiologist interpretation in a simulated clinical workflow. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Philpotts in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Shoshan, Bakalo, Gilboa-Solomon, et al. Artificial Intelligence for Reducing Workload in Breast Cancer Screening with Digital Breast Tomosynthesis. Radiology. 2022. PMID: 35040677. doi:10.1148/radiol.211105

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。