文献速递妇产影像US

胎儿体重投影模型定义生长速度并在连续超声扫描妊娠队列中验证妊娠结局

Fetal weight projection model to define growth velocity and validation against pregnancy outcome in a cohort of serially scanned pregnancies.
PubMed 文献 · Ultrasound Obstet Gynecol · 2022-06-08

本研究基于102138例单胎妊娠的队列,建立按测量间隔特异性的胎儿体重生长速度正常限值模型,并验证其与围产期结局的关联。结果显示,慢速生长与死产(RR 2.19)和新生儿死亡(RR 2.28)等不良结局显著相关,加速生长与大于胎龄儿相关(RR 2.15),而正常生长对所有不良结局具有保护作用。作者结论认为,基于投影、测量间隔特异性胎儿体重限值定义的胎儿生长速度独立与围产期结局相关,应在产前监测中与胎儿大小评估一起使用。

要点

  • 生长速度正常限值随测量间隔变化,固定假阳性率10%时平均慢速生长界值为-8.0%、加速生长界值为+9.3%。
  • 慢速生长与死产(RR 2.19,95%CI 1.84-2.53)和新生儿死亡(RR 2.28,95%CI 1.60-3.13)等所有预设结局显著相关。
  • 66.2%的慢速生长妊娠在末次扫描时并非小于胎龄儿,但这些病例死产风险仍增加(RR 2.07,95%CI 1.40-3.05)。

核心结论

  • 基于投影、测量间隔特异性胎儿体重限值定义的胎儿生长速度独立与围产期结局相关,应在产前监测中与胎儿大小评估一起使用。

研究设计与样本

  • 队列研究,纳入102138例单胎妊娠,均于妊娠晚期至少进行两次超声估测胎儿体重(EFW)测量,通常因早孕期常规风险评估提示胎儿生长受限风险增加而进行。
  • 通过将每对连续测量中第一次的EFW沿其自身百分位秩投影至第二次扫描的孕龄,定义正常生长为第二次EFW落在基于部分受试者工作特征曲线(pROC)分析得出的体重范围内。
  • 生长限值为测量间隔特异性,并针对小于胎龄儿(SGA;出生体重<第10百分位)和大于胎龄儿(LGA;出生体重>第90百分位)在固定假阳性率10%下计算。

诊断标准与关键数值

  • 正常生长速度的最佳截断限值随连续扫描间测量间隔长度变化,固定假阳性率10%时,慢速生长平均界值为-8.0%,加速生长平均界值为+9.3%。
  • 慢速生长与死产(RR 2.19;95%CI 1.84-2.53)和新生儿死亡(RR 2.28;95%CI 1.60-3.13)等所有预设结局显著相关;加速生长与出生时LGA相关(RR 2.15;95%CI 2.10-2.20);正常生长对所有不良结局具有保护作用。
  • 末次两次扫描(中位孕龄33+1至36+4周)间的慢速生长和末次扫描时SGA均为死产的预测因素,两者同时存在时死产风险最高(RR 2.65;95%CI 1.67-4.20)。
  • 66.2%的慢速生长妊娠在末次扫描时并非SGA,这些病例死产风险亦增加(RR 2.07;95%CI 1.40-3.05)。

临床应用与阅片要点

  • 产前监测中,除评估胎儿大小外,应使用基于投影、测量间隔特异性胎儿体重限值定义的胎儿生长速度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Fetal growth assessment is central to good antenatal care, yet there is a lack of definition of normal and abnormal fetal growth rate which can identify pregnancies at risk of adverse outcome. The aim of this study was to develop and test a model for defining normal limits of growth velocity which are specific to the fetal weight measurement interval.

METHODS: The cohort consisted of 102 138 singleton pregnancies which underwent at least two third-trimester measurements of ultrasound estimated fetal weight (EFW), usually carried out because routine early-pregnancy risk assessment had indicated an increased risk of fetal growth restriction. We projected the EFW from the first of each consecutive measurement pair along its own centile rank to the gestational age of the second scan. Normal growth was defined as the second EFW being within a weight range based on limits derived by partial receiver-operating-characteristics-curve (pROC) analyses for small-for-gestational-age (SGA; < 10th centile) and large-for-gestational-age (LGA; > 90th centile) birth weight. The limits were measurement-interval specific and calculated for a fixed false-positive rate (FPR) of 10%. The resultant normal, slow and accelerated growth rates calculated from consecutive EFW pairs were evaluated against the following predefined perinatal outcome measures: stillbirth, neonatal death, SGA and LGA at birth, 5-min Apgar score < 7 and admission to the neonatal intensive care unit. Slow growth based on the last two scans was compared with SGA fetal weight (EFW < 10th centile) at the last scan and association with stillbirth risk was assessed, expressed as relative risk (RR) with 95% CI.

RESULTS: The optimal cut-off limits for normal growth rate between consecutive scans varied according to the length of the measurement interval, with an average of -8.0% for slow growth and + 9.3% for accelerated growth at a fixed FPR of 10%. Slow growth between random consecutive scan pairs was associated significantly with all predefined outcome measures including stillbirth (RR, 2.19; 95% CI, 1.84-2.53) and neonatal death (RR, 2.28; 95% CI, 1.60-3.13). Accelerated growth was associated with LGA at birth (RR, 2.15; 95% CI, 2.10-2.20), while normal growth was protective of all adverse outcome measures. Slow growth between the last two scans (which were performed at a median gestational age of 33 + 1 to 36 + 4 weeks) and SGA at the last scan were each predictors of stillbirth, and stillbirth risk was highest when both were present (RR, 2.65; 95% CI, 1.67-4.20). However, 66.2% of pregnancies with slow growth were not SGA at the last scan and these cases also had an increased risk of stillbirth (RR, 2.07; 95% CI, 1.40-3.05).

CONCLUSION: Fetal growth velocity defined by projected, measurement-interval specific fetal weight limits is associated independently with perinatal outcome and should be used for antenatal surveillance in addition to assessment by fetal size. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Hugh, Gardosi. Fetal weight projection model to define growth velocity and validation against pregnancy outcome in a cohort of serially scanned pregnancies. Ultrasound Obstet Gynecol. 2022. PMID: 35041244. doi:10.1002/uog.24860

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。