文献速递胸部CT

深度学习重建在超低剂量胸部CT中显示更好的肺结节检测能力

Deep Learning Reconstruction Shows Better Lung Nodule Detection for Ultra-Low-Dose Chest CT.
PubMed 文献 · Radiology · 2022-01-18

这项前瞻性研究纳入203例受试者(1066个结节),比较超低剂量胸部CT(0.07或0.14 mSv)中深度学习图像重建(DLIR)与自适应统计迭代重建-V(ASIR-V)的图像质量和肺结节检出率。DLIR高强度的肺组织噪声低于ASIR-V 80%,结节检出率更高(75.8% vs 73.3%),长径测量百分比差异更小(6.2% vs 9.2%)。

要点

  • 超低剂量胸部CT(0.07或0.14 mSv)采用高强度DLIR重建,肺组织噪声低于ASIR-V 80%。
  • 高强度DLIR结节检出率75.8%,高于ASIR-V 80%的73.3%和FBP的62.5%。
  • 高强度DLIR长径测量与增强胸部CT的百分比差异6.2%,小于ASIR-V 80%的9.2%和FBP的9.3%。

核心结论

  • 与自适应统计迭代重建-V相比,深度学习图像重建降低了超低剂量胸部CT的图像噪声、提高了结节检出率并改善了测量准确性。

研究设计与样本

  • 前瞻性研究,纳入2020年4月至6月接受非增强超低剂量胸部CT(0.07或0.14 mSv)和增强胸部CT的患者203例(平均年龄61岁±12,129名男性),共1066个结节,其中100次扫描为0.07 mSv、103次扫描为0.14 mSv。

关键影像表现/征象

  • 肺组织平均噪声:增强胸部CT为46 HU±4,超低剂量CT的FBP为59 HU±4,ASIR-V 40%为56 HU±4,ASIR-V 80%为53 HU±4,中等强度DLIR为54 HU±4,高强度DLIR为51 HU±4(P < .001)。

诊断标准与关键数值

  • 结节检出率:FBP重建为62.5%(666/1066个结节),ASIR-V 80%为73.3%(781/1066个结节),高强度DLIR为75.8%(808/1066个结节)(P < .001)。
  • 长径与增强胸部CT的百分比差异:FBP重建为9.3%(均值95%CI:8.0,10.6),ASIR-V 80%为9.2%(均值95%CI:8.0,10.4),高强度DLIR为6.2%(均值95%CI:5.0,7.4)(P < .001)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Ultra-low-dose (ULD) CT could facilitate the clinical implementation of large-scale lung cancer screening while minimizing the radiation dose. However, traditional image reconstruction methods are associated with image noise in low-dose acquisitions. Purpose To compare the image quality and lung nodule detectability of deep learning image reconstruction (DLIR) and adaptive statistical iterative reconstruction-V (ASIR-V) in ULD CT. Materials and Methods Patients who underwent noncontrast ULD CT (performed at 0.07 or 0.14 mSv, similar to a single chest radiograph) and contrast-enhanced chest CT (CECT) from April to June 2020 were included in this prospective study. ULD CT images were reconstructed with filtered back projection (FBP), ASIR-V, and DLIR. Three-dimensional segmentation of lung tissue was performed to evaluate image noise. Radiologists detected and measured nodules with use of a deep learning-based nodule assessment system and recognized malignancy-related imaging features. Bland-Altman analysis and repeated-measures analysis of variance were used to evaluate the differences between ULD CT images and CECT images. Results A total of 203 participants (mean age ± standard deviation, 61 years ± 12; 129 men) with 1066 nodules were included, with 100 scans at 0.07 mSv and 103 scans at 0.14 mSv. The mean lung tissue noise ± standard deviation was 46 HU ± 4 for CECT and 59 HU ± 4, 56 HU ± 4, 53 HU ± 4, 54 HU ± 4, and 51 HU ± 4 in FBP, ASIR-V level 40%, ASIR-V level 80% (ASIR-V-80%), medium-strength DLIR, and high-strength DLIR (DLIR-H), respectively, of ULD CT scans (P < .001). The nodule detection rates of FBP reconstruction, ASIR-V-80%, and DLIR-H were 62.5% (666 of 1066 nodules), 73.3% (781 of 1066 nodules), and 75.8% (808 of 1066 nodules), respectively (P < .001). Bland-Altman analysis showed the percentage difference in long diameter from that of CECT was 9.3% (95% CI of the mean: 8.0, 10.6), 9.2% (95% CI of the mean: 8.0, 10.4), and 6.2% (95% CI of the mean: 5.0, 7.4) in FBP reconstruction, ASIR-V-80%, and DLIR-H, respectively (P < .001). Conclusion Compared with adaptive statistical iterative reconstruction-V, deep learning image reconstruction reduced image noise, increased nodule detection rate, and improved measurement accuracy on ultra-low-dose chest CT images. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Lee in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Jiang, Li, Shi, et al. Deep Learning Reconstruction Shows Better Lung Nodule Detection for Ultra-Low-Dose Chest CT. Radiology. 2022. PMID: 35040674. doi:10.1148/radiol.210551

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。