指南与共识甲状腺与浅表US

比较ACR TI-RADS、Kwak TI-RADS与ATA指南推荐的甲状腺结节FNA率

Comparison of thyroid nodule FNA rates recommended by ACR TI-RADS, Kwak TI-RADS and ATA guidelines.
指南 / 共识 · Eur J Radiol · 2022-01-07

该研究比较ACR TI-RADS、Kwak TI-RADS与ATA指南推荐FNA的特异度、敏感度和不必要FNA率(UFR)。全部甲状腺结节中,ACR TI-RADS的UFR为26.3%,低于ATA指南的47.4%和Kwak TI-RADS的40.0%;ACR TI-RADS特异度73.7%高于其他两者,但敏感度89.3%低于其他两者(均P<0.001)。提高ATA指南中危、低危、极低危及Kwak TI-RADS 4b、4a级的FNA结节大小阈值后,UFR逐渐降低。

要点

  • ACR TI-RADS推荐FNA的不必要FNA率26.3%,低于ATA指南47.4%和Kwak TI-RADS 40.0%。
  • ACR TI-RADS推荐FNA特异度73.7%高于其他两者,敏感度89.3%低于其他两者(均P<0.001)。
  • 提高ATA中危、低危、极低危及Kwak 4b、4a级的FNA大小阈值可使UFR逐渐降低。

核心结论

  • Kwak TI-RADS和ATA指南推荐FNA的UFR高于ACR TI-RADS,且受推荐FNA结节大小阈值影响。

研究设计与样本

  • 研究计算并比较ACR TI-RADS、ATA指南和Kwak TI-RADS推荐FNA的特异度、敏感度和UFR,并系统改变ATA指南和Kwak TI-RADS的FNA结节大小阈值建立新阈值模型后与ACR TI-RADS比较。

诊断标准与关键数值

  • 全部甲状腺结节中,ACR TI-RADS、ATA指南和Kwak TI-RADS推荐FNA的UFR分别为26.3%、47.4%和40.0%。
  • ACR TI-RADS推荐FNA特异度73.7%高于其他两者,敏感度89.3%低于其他两者,均P<0.001。
  • 逐渐提高ATA指南中危、低危、极低危及Kwak TI-RADS 4b、4a级的推荐FNA结节大小阈值后,UFR逐渐降低。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the differences among the thyroid imaging reporting and data system (TI-RADS) proposed by American College of Radiology (ACR TI-RADS), TI-RADS proposed by Kwak (Kwak TI-RADS), and American Thyroid Association (ATA) guidelines in the specificity, sensitivity and the unnecessary FNA rate (the UFR, the false positive rate) of recommended fine needle aspiration (FNA), and to observe the changes of the UFR in the KwakTI-RADS and ATA guidelines with the recommended FNA nodule size threshold.

METHODS: The specificities, sensitivities and UFRs of recommended FNA in the ACR TI-RADS, ATA guidelines and Kwak TI-RADS were calculated and compared. The nodule sizes for recommended FNA of ATA guidelines and Kwak TI-RADS were systematically varied to establish new FNA thresholds. The specificities, sensitivities and UFRs of recommended FNA under the new models were calculated and compared to those in the ACR TI-RADS.

RESULTS: For all thyroid nodules, the UFRs in the ACR TI-RADS, ATA guidelines and Kwak TI-RADS were 26.3%, 47.4% and 40.0%, respectively. The UFR in the ACR TI-RADS was lower than that in the others, and the specificity of recommended FNA in the ACR TI-RADS(73.7%) was higher than that in the others (all P < 0.001), but the sensitivity of recommended FNA in the ACR TI-RADS(89.3%) was lower than that in the others (all P < 0.001). When nodule sizes threshold of the recommended FNA for ATA guidelines Intermediate Suspicion, Low Suspicion, and Very Low Suspicion, and Kwak TI-RADS grade 4b and 4a were gradually increased, the UFRs gradually decreased.

CONCLUSIONS: The UFRs of FNA recommended by the Kwak TI-RADS and ATA guidelines were higher than that of the ACR TI-RADS, and were affected by the recommended FNA nodule size threshold.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Qi, Chen, Liu, et al. Comparison of thyroid nodule FNA rates recommended by ACR TI-RADS, Kwak TI-RADS and ATA guidelines. Eur J Radiol. 2022. PMID: 35033941. doi:10.1016/j.ejrad.2022.110152

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。