儿童肺炎支原体肺炎合并肺栓塞的双能谱CT成像研究

Dual-energy spectral CT imaging of pulmonary embolism with Mycoplasma pneumoniae pneumonia in children.
PubMed 文献 · Radiol Med · 2022-01-16

本研究纳入83例高度怀疑肺栓塞的肺炎支原体肺炎患儿,均行双能谱CT肺动脉造影,其中25例确诊肺栓塞。结果显示55 keV为儿童肺栓塞检测的最佳单能量水平,碘图可量化肺血流灌注,有助于检测小血栓并量化栓塞程度。

要点

  • 儿童肺炎支原体肺炎合并肺栓塞疑似病例中,55 keV单能量图像为检测肺栓塞的最佳能量水平。
  • 碘图可量化肺血流灌注,灌注缺损区碘浓度显著低于正常肺组织及无血栓实变区。
  • 闭塞性血栓较非闭塞性血栓更易出现灌注缺损,治疗后灌注缺损区碘浓度显著升高。

核心结论

  • 在双能谱CT肺动脉造影中,55 keV图像优化了儿童肺栓塞的检测。
  • 碘图可量化肺栓塞的肺血流灌注,可能有助于检测小血栓并量化栓塞程度。

研究设计与样本

  • 研究纳入83例肺炎支原体肺炎且高度怀疑肺栓塞的儿童,均行双能谱CT肺动脉造影,其中25例确诊肺栓塞。
  • 在40至80 keV的九个单能量图像集上计算并评估噪声、血栓与动脉的对比噪声比、图像质量和诊断信心。
  • 观察CTPA图像上肺栓塞的存在、定位和栓塞程度,血栓分为实变内血栓和实变外血栓。

关键影像表现/征象

  • 共发现116个血栓,其中29个为实变外血栓。
  • 实变外血栓灌注缺损区碘浓度为0.69 ± 0.28 mg/mL,实变内血栓灌注缺损区碘浓度为0.90 ± 0.23 mg/mL,均显著低于正常肺组织的2.76 ± 0.45 mg/mL和无血栓实变区的10.25 ± 1.76 mg/mL(P < 0.001)。
  • 闭塞性血栓与非闭塞性血栓在灌注缺损存在与否方面差异有统计学意义(P < 0.001)。
  • 4例患儿治疗前后灌注缺损区碘浓度显著升高(P < 0.001)。

诊断标准与关键数值

  • 儿童肺栓塞检测的最佳单能量水平为55 keV。
  • 实变外血栓灌注缺损区碘浓度为0.69 ± 0.28 mg/mL,实变内血栓灌注缺损区碘浓度为0.90 ± 0.23 mg/mL。
  • 正常肺组织碘浓度为2.76 ± 0.45 mg/mL,无血栓实变区碘浓度为10.25 ± 1.76 mg/mL。
  • 闭塞性与非闭塞性血栓在灌注缺损存在与否方面差异有统计学意义(P < 0.001)。

临床应用与阅片要点

  • 儿童肺炎支原体肺炎合并肺栓塞疑似病例行双能谱CT肺动脉造影时,55 keV单能量图像有助于优化肺栓塞检测。
  • 碘图可量化肺血流灌注,可能有助于检测小血栓并量化栓塞程度。
  • 阅片时需注意区分实变内血栓与实变外血栓,并观察闭塞性与非闭塞性血栓的灌注缺损差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Pulmonary embolism (PE) associated with Mycoplasma pneumoniae pneumonia (MPP) in children has already attracted more attention. CT pulmonary angiography (CTPA) has been the preferred method for diagnosing PE, but it has some limitations, especially for children. Dual-energy spectral CT has been used in diagnosing PE in adults.

PURPOSE: To evaluate the application of dual-energy spectral CT in diagnosing PE in children with MPP.

MATERIALS AND METHODS: Eighty-three children with MPP and highly suspected PE, underwent CTPA with spectral imaging mode, 25 children were diagnosis with PE. Noise, clot-to-artery contrast-to-noise ratio, image quality and diagnosis confidence were calculated and assessed on nine monochromatic image sets (40 to 80 keV). CTPA images were observed for the presence, localization and embolic degrees of PE. Clots were divided into intra- and extra-consolidation clots. For extra-consolidation clots, iodine concentration (IC) of perfusion defects and normal lung, perfusion defects of four children before and after the treatment were measured and compared. For intra-consolidation clots, IC of consolidation areas with clots and consolidation areas without clot were measured and compared.

RESULTS: The optimal energy level for detecting PE in children was 55 keV. 116 clots (29 extra-consolidations) were found, IC of defect regions was 0.69 ± 0.28 mg/mL (extra-consolidations) and 0.90 ± 0.23 mg/mL (intra-consolidations), both significantly lower than the 2.76 ± 0.45 mg/mL in normal lungs and 10.25 ± 1.76 mg/mL in consolidations without clots (P < 0.001). Significant difference was found in the presence or absence of perfusion defects between occlusive clots and nonocclusive clots (P < 0.001). IC of the perfusion defects significantly increased after treatment (P < 0.001).

CONCLUSIONS: In dual-energy spectral CTPA, 55 keV images optimize PE detection for children, and MD images quantify pulmonary blood flow of PE, and may help to detect small clots and quantify embolic degrees.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Yang, Sun, Li, et al. Dual-energy spectral CT imaging of pulmonary embolism with Mycoplasma pneumoniae pneumonia in children. Radiol Med. 2022. PMID: 35034318. doi:10.1007/s11547-021-01442-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。