文献速递介入外周血管胸部CT

CT引导下经胸肺动脉导管置入术:猪模型的实验研究

CT-guided transthoracic pulmonary artery catheterization: an experimental study in a porcine model.
PubMed 文献 · Eur Radiol · 2022-01-15

在10只成熟巴马小型猪中评估CT引导下经胸肺动脉导管置入术(TPAC)的安全性和可行性,11次手术中10次成功,技术成功率90.9%,并发症均可自行缓解,平均肺动脉压32±17.6 mmHg,所有动物存活至8周随访终点。作者认为该技术在猪模型中可行且安全,可能成为肺动脉介入的替代途径。

要点

  • CT引导下经胸肺动脉导管置入术在猪模型中技术成功率为90.9%(10/11)。
  • 并发症包括针道肺出血(3/11;27.3%)、肺动脉穿刺点未闭合(3/10;30%)、气胸(1/11;9.1%)和心包积血(1/11;9.1%),均自行缓解。
  • 所有动物存活至8周随访终点,平均肺动脉压为32±17.6 mmHg。

核心结论

  • CT引导下TPAC在猪模型中可行且安全,可能成为肺动脉介入的替代途径。

研究设计与样本

  • 实验研究,在10只成熟巴马小型猪中进行,共实施11次CT引导下TPAC手术,左侧卧位行胸部CT确定穿刺路径,采用Seldinger技术经右胸壁将导引鞘插入右肺动脉,随访8周评估手术相关并发症和生存情况。

关键影像表现/征象

  • CT引导下确定穿刺路径,采用Seldinger技术经右胸壁将导引鞘置入右肺动脉。
  • 置入连接换能器的导管测量肺动脉压力,平均肺动脉压为32±17.6 mmHg。
  • 术后使用主动闭合器闭合肺动脉穿刺点。

诊断标准与关键数值

  • 技术成功率90.9%(10/11次手术成功)。
  • 针道肺出血发生率27.3%(3/11),肺动脉穿刺点未闭合发生率30%(3/10),气胸发生率9.1%(1/11),心包积血发生率9.1%(1/11)。
  • 所有动物存活至8周随访终点。

临床应用与阅片要点

  • 作者认为CT引导下TPAC在猪模型中可行且安全,可能成为肺动脉介入的替代途径。
  • 作者指出该新方法可更快到达肺动脉,且可能更容易操作导管尖端超选择进入目标肺动脉分支。
  • 作者认为TPAC可能成为存在机械性右心瓣膜、大血管转位及其他障碍患者的替代肺动脉介入途径。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We investigated the safety and feasibility of CT-guided transthoracic pulmonary artery catheterization (TPAC) in a porcine model.

METHODS: Procedures were conducted on ten mature Bama miniature pigs. After anesthesia, chest CT was performed in the left lateral decubitus position to determine the puncture route. Under the guidance of multiple CT scans, the introducer sheath was inserted from the right chest wall of the pig into the right pulmonary artery using the Seldinger technique. Then, a catheter connected with a transducer was inserted into the sheath to measure the pulmonary artery pressure. Finally, an active approximator was used to close the puncture site on the pulmonary artery. The pigs were followed up for 8 weeks to evaluate the operation-related complications and survival.

RESULTS: Ten of 11 CT-guided TPAC procedures were successfully performed on ten pigs, rendering a technical success rate of 90.9%. One pig had hemoptysis while the needle was being inserted during the first operation, and a second procedure was successfully conducted 17 days later. Other complications, including pulmonary bleeding along the needle track (3 of 11; 27.3%), unclosed pulmonary artery puncture sites (3 of 10; 30%), pneumothorax (1 of 11; 9.1%), and hemopericardium (1 of 11; 9.1%), spontaneously resolved without complication-specific treatment. The mean pulmonary arterial pressure was 32 ± 17.6 mmHg. All animals survived the procedure and reached the end of the follow-up period.

CONCLUSIONS: CT-guided TPAC is feasible and safe in a porcine model, serving as a potential alternative pathway for pulmonary artery intervention.

KEY POINTS: • TPAC is feasible and safe in a porcine model, serving as a potential alternative pathway for pulmonary artery intervention. • This novel approach allows for faster access to the pulmonary artery, and it might be easier to operate the tip of the catheter to super-select the intent branch of the pulmonary artery. • TPAC can be an alternative pulmonary artery intervention pathway in patients with mechanical right-heart valves, great-vessel transposition, and other obstacles.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ye, Jiang, Yang, et al. CT-guided transthoracic pulmonary artery catheterization: an experimental study in a porcine model. Eur Radiol. 2022. PMID: 35031843. doi:10.1007/s00330-021-08434-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。