文献速递胸部CT

COVID-19胸部CT严重程度评分系统的比较

Comparison of chest CT severity scoring systems for COVID-19.
PubMed 文献 · Eur Radiol · 2022-01-15

该回顾性研究纳入85例PCR确诊COVID-19患者,由3名阅片者用5种胸部CT严重程度评分系统评估肺部受累并记录报告耗时,比较诊断性能和观察者间一致性。结果显示各系统均有优良的观察者间一致性和合理性能,胸部CT评分与TSS特异度最高,TSS与m-TSS耗时最少。

要点

  • 各评分系统判断重症的截断值不同:CT-SS>22、胸部CT评分>17、TSS>12、3级CT评分>26。
  • 胸部CT评分区分重症的特异度最高(95.2%),CT-SS与TSS特异度也较高。
  • 报告耗时CT-SS>3L-CT-SS>胸部CT评分>TSS,TSS与m-TSS耗时最少。

核心结论

  • 所有胸部CT严重程度评分系统均显示优良的观察者间一致性和评估COVID-19临床严重程度的合理性能。
  • CT-SS和TSS特异度最高且判读耗时最少。

研究设计与样本

  • 回顾性研究,纳入85例PCR确诊COVID-19患者(男54例、女31例),行CT评估肺部受累程度。
  • 3名阅片者评估肺部异常并用5种系统评分:胸部CT严重程度评分(CT-SS)、胸部CT评分、总严重程度评分(TSS)、改良总严重程度评分(m-TSS)和3级胸部CT严重程度评分。
  • 计算每种系统报告耗时,每种系统共255次观察记录。

关键影像表现/征象

  • 使用m-TSS评估定性肺部受累时,观察者间一致性有统计学意义,其他四种定量系统亦然。

诊断标准与关键数值

  • 检测重症的截断值:CT-SS>22、胸部CT评分>17、TSS>12、3级CT严重程度评分>26。
  • 对应AUC分别为0.86(很好)、0.90(极好)、0.89(很好)、0.86(很好)。
  • 胸部CT评分区分重症的特异度最高(95.2%)。

临床应用与阅片要点

  • 报告耗时有显著差异(P<0.001):CT-SS>3L-CT-SS>胸部CT评分>TSS。
  • TSS和m-TSS相较其他三种评分系统耗时最少。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the diagnostic performance and inter-observer agreement of five different CT chest severity scoring systems for COVID-19 to find the most precise one with the least interpretation time.

METHODS AND MATERIALS: This retrospective study included 85 patients (54 male and 31 female) with PCR-confirmed COVID-19. They underwent CT to assess the severity of pulmonary involvement. Three readers were asked to assess the pulmonary abnormalities and score the severity using five different systems, including chest CT severity score (CT-SS), chest CT score, total severity score (TSS), modified total severity score (m-TSS), and 3-level chest CT severity score. Time consumption on reporting of each system was calculated.

RESULTS: Two hundred fifty-five observations were reported for each system. There was a statistically significant inter-observer agreement in assessing qualitative lung involvement using the m-TSS and the other four quantitative systems. The ROC curves revealed excellent and very good diagnostic accuracy for all systems when cutoff values for detection severe cases were > 22, > 17, > 12, and > 26 for CT-SS, chest CT score, TSS, and 3-level CT severity score. The AUC was very good (0.86), excellent (0.90), very good (0.89), and very good (0.86), respectively. Chest CT score showed the highest specificity (95.2%) in discrimination of severe cases. Time consumption on reporting was significantly different (< 0.001): CT-SS > 3L-CT-SS > chest CT score > TSS.

CONCLUSION: All chest CT severity scoring systems in this study demonstrated excellent inter-observer agreement and reasonable performance to assess COVID-19 in relation to the clinical severity. CT-SS and TSS had the highest specificity and least time for interpretation.

KEY POINTS: • All chest CT severity scoring systems discussed in this study revealed excellent inter-observer agreement and reasonable performance to assess COVID-19 in relation to the clinical severity. • Chest CT scoring system and TSS had the highest specificity. • Both TSS and m-TSS consumed the least time compared to the other three scoring systems.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Elmokadem, Mounir, Ramadan, et al. Comparison of chest CT severity scoring systems for COVID-19. Eur Radiol. 2022. PMID: 35031841. doi:10.1007/s00330-021-08432-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。