深度学习辅助诊断儿童颅骨骨折的X线平片研究
这项回顾性多中心研究开发并评估了基于深度学习的人工智能模型在儿童X线平片上检测颅骨骨折的性能,以头颅CT为参考标准。模型在内外部测试集的AUROC分别为0.922和0.870,辅助 inexperienced 放射科住院医师和急诊医师时AUROC显著提升,但对儿科放射科医师无显著提升。
要点
- AI模型在外部测试集AUROC为0.870,敏感度78.9%,特异度88.2%。
- AI辅助使放射科住院医师AUROC提升0.094(p=0.012),急诊医师提升0.069(p=0.043)。
- 对儿科放射科医师AUROC提升0.008(p=0.850),无显著改善。
核心结论
- 基于深度学习的人工智能模型提高了经验不足的放射科医师和急诊医师在X线平片上诊断儿童颅骨骨折的性能。
研究设计与样本
- 回顾性多中心研究,开发数据集来自两家医院(n=149和264),外部测试集来自第三家医院(n=95),纳入同时接受颅骨X线摄影和头颅CT的头部外伤儿童,以头颅CT为颅骨骨折参考标准;开发数据集按7:1:2分为训练集、调优集和内部测试集;两名放射科住院医师、一名儿科放射科医师和两名急诊医师参与外部测试集的有无AI辅助的两次阅片者研究。
诊断标准与关键数值
- AI模型内部测试集AUROC 0.922(95%CI 0.842-0.969),敏感度81.1%(95%CI 64.8%-92.0%),特异度91.3%(95%CI 79.2%-97.6%);外部测试集AUROC 0.870(95%CI 0.785-0.930),敏感度78.9%(95%CI 54.4%-93.9%),特异度88.2%(95%CI 78.7%-94.4%)。
临床应用与阅片要点
- AI辅助后放射科住院医师(汇总结果)AUROC较无AI辅助提高0.094(95%CI 0.020-0.168;p=0.012),急诊医师(汇总结果)提高0.069(95%CI 0.002-0.136;p=0.043),儿科放射科医师提高0.008(95%CI -0.074-0.090;p=0.850)无显著改善。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To develop and evaluate a deep learning-based artificial intelligence (AI) model for detecting skull fractures on plain radiographs in children.
MATERIALS AND METHODS: This retrospective multi-center study consisted of a development dataset acquired from two hospitals (n = 149 and 264) and an external test set (n = 95) from a third hospital. Datasets included children with head trauma who underwent both skull radiography and cranial computed tomography (CT). The development dataset was split into training, tuning, and internal test sets in a ratio of 7:1:2. The reference standard for skull fracture was cranial CT. Two radiology residents, a pediatric radiologist, and two emergency physicians participated in a two-session observer study on an external test set with and without AI assistance. We obtained the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity along with their 95% confidence intervals (CIs).
RESULTS: The AI model showed an AUROC of 0.922 (95% CI, 0.842-0.969) in the internal test set and 0.870 (95% CI, 0.785-0.930) in the external test set. The model had a sensitivity of 81.1% (95% CI, 64.8%-92.0%) and specificity of 91.3% (95% CI, 79.2%-97.6%) for the internal test set and 78.9% (95% CI, 54.4%-93.9%) and 88.2% (95% CI, 78.7%-94.4%), respectively, for the external test set. With the model's assistance, significant AUROC improvement was observed in radiology residents (pooled results) and emergency physicians (pooled results) with the difference from reading without AI assistance of 0.094 (95% CI, 0.020-0.168; p = 0.012) and 0.069 (95% CI, 0.002-0.136; p = 0.043), respectively, but not in the pediatric radiologist with the difference of 0.008 (95% CI, -0.074-0.090; p = 0.850).
CONCLUSION: A deep learning-based AI model improved the performance of inexperienced radiologists and emergency physicians in diagnosing pediatric skull fractures on plain radiographs.
引用
- Choi, Cho, Ha, et al. Deep Learning-Assisted Diagnosis of Pediatric Skull Fractures on Plain Radiographs. Korean J Radiol. 2022. PMID: 35029078. doi:10.3348/kjr.2021.0449
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。