Silent MRA在支架辅助弹簧圈栓塞术后动脉瘤评估中的价值
本研究纳入99例患者(101个动脉瘤)在支架辅助弹簧圈栓塞术后24小时内行3T MRI的TOF MRA与Silent MRA检查,两名放射科医生独立回顾性判读图像质量并评估动脉瘤闭塞诊断准确性。结果显示Silent MRA图像质量评分显著高于TOF MRA(4.38±0.83 vs 2.78±1.04,p<0.001),且在Neuroform Atlas支架和LVIS Jr支架组中Silent MRA检测动脉瘤闭塞的敏感度显著更高。结论认为Silent MRA可用于评估支架辅助弹簧圈栓塞术后的动脉瘤。
要点
- Silent MRA图像质量评分显著高于TOF MRA(4.38±0.83 vs 2.78±1.04,p<0.001)。
- Neuroform Atlas支架组Silent MRA检测闭塞敏感度96.4% vs TOF MRA 14.3%(p<0.001)。
- LVIS Jr支架组Silent MRA检测闭塞敏感度100% vs TOF MRA 20%(p=0.046)。
核心结论
- Silent MRA可用于评估支架辅助弹簧圈栓塞术后的动脉瘤,不受动脉瘤位置和支架类型限制。
研究设计与样本
- 回顾性研究,纳入99例患者共101个支架辅助弹簧圈栓塞的动脉瘤(Neuroform Atlas 71例、Enterprise 17例、LVIS Jr 9例、Solitaire AB 4例),栓塞术后24小时内使用3T MRI系统同一次检查中行TOF MRA和Silent MRA,两名放射科医生独立判读。
诊断标准与关键数值
- 图像质量采用5分Likert量表评分;Silent MRA与TOF MRA平均图像质量评分分别为4.38±0.83和2.78±1.04(p<0.001);Neuroform Atlas支架组检测动脉瘤闭塞敏感度Silent MRA 96.4% vs TOF MRA 14.3%(p<0.001);LVIS Jr支架组敏感度Silent MRA 100% vs TOF MRA 20%(p=0.046)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine the usefulness of Silent MR angiography (MRA) for evaluating intracranial aneurysms treated with stent-assisted coil embolization.
MATERIALS AND METHODS: Ninety-nine patients (101 aneurysms) treated with stent-assisted coil embolization (Neuroform atlas, 71 cases; Enterprise, 17; LVIS Jr, 9; and Solitaire AB, 4 cases) underwent time-of-flight (TOF) MRA and Silent MRA in the same session using a 3T MRI system within 24 hours of embolization. Two radiologists independently interpreted both MRA images retrospectively and rated the image quality using a 5-point Likert scale. The image quality and diagnostic accuracy of the two modalities in the detection of aneurysm occlusion were further compared based on the stent design and the site of aneurysm.
RESULTS: The average image quality scores of the Silent MRA and TOF MRA were 4.38 ± 0.83 and 2.78 ± 1.04, respectively (p < 0.001), with an almost perfect interobserver agreement. Silent MRA had a significantly higher image quality score than TOF MRA at the distal internal carotid artery (n = 57, 4.25 ± 0.91 vs. 3.05 ± 1.16, p < 0.001), middle cerebral artery (n = 21, 4.57 ± 0.75 vs. 2.19 ± 0.68, p < 0.001), anterior cerebral artery (n = 13, 4.54 ± 0.66 vs. 2.46 ± 0.66, p < 0.001), and posterior circulation artery (n = 10, 4.50 ± 0.71 vs. 2.90 ± 0.74, p = 0.013). Silent MRA had superior image quality score to TOF MRA in the stented arteries when using Neuroform atlas (4.66 ± 0.53 vs. 3.21 ± 0.84, p < 0.001), Enterprise (3.29 ± 1.59 vs. 1.59 ± 0.51, p = 0.003), LVIS Jr (4.33 ± 1.89 vs. 1.89 ± 0.78, p = 0.033), and Solitaire AB stents (4.00 ± 2.25 vs. 2.25 ± 0.96, p = 0.356). The interpretation of the status of aneurysm occlusion exhibited significantly higher sensitivity with Silent MRA than with TOF MRA when using the Neuroform Atlas stent (96.4% vs. 14.3%, respectively, p < 0.001) and LVIS Jr stent (100% vs. 20%, respectively, p = 0.046).
CONCLUSION: Silent MRA can be useful to evaluate aneurysms treated with stent-assisted coil embolization, regardless of the aneurysm location and type of stent used.
引用
- Kim, Choi, Lim, et al. Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization. Korean J Radiol. 2022. PMID: 35029075. doi:10.3348/kjr.2021.0332
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。