指南与共识技术与安全

临床决策支持系统推荐:放射科医生和临床医生接受度如何

Clinical decision support system recommendations: how often do radiologists and clinicians accept them?
指南 / 共识 · Eur Radiol · 2022-01-13

在一家三级医院开展的试点研究中,四位专家对40个模拟临床病例的ESR iGuide推荐程序进行1-5级一致性评分,平均评分4.17±0.65,中位数4.25;四位评分者在75%的病例中完全同意系统推荐,总体百分比一致性为77.28%,160例次中共20次不一致(其中7次来自两位放射科医生)。作者认为CDSS可有效指导合理选择影像检查,但作为试点研究需更大规模(最好是国家层面)的进一步研究。

要点

  • 四位专家对40个模拟病例的ESR iGuide推荐平均评分4.17±0.65(1-5分),中位数4.25。
  • 四位评分者在75%的病例中完全同意系统推荐,二元同意/不同意变量的总体百分比一致性为77.28%。
  • 放射科医生与CDSS推荐的不一致次数少于其他医生,提示支持系统更契合放射科专家视角。

核心结论

  • CDSS可作为指导选择适当影像检查的有效工具,从而减少因不必要影像扫描产生的费用。
  • 由于是试点研究,需要在更大规模(最好是国家层面)开展进一步研究。

研究设计与样本

  • 在一家三级医院开展的试点研究。
  • 四位不同专家对40个模拟临床病例按1-5级量表评分,评估与ESR iGuide推荐程序的一致性程度。
  • 意见不一致时要求医生说明原因,并计算一致性的描述性指标。
  • 探索四位不同专科医生之间的一致性程度,并检查临床医生不同意ESR iGuide最佳实践推荐的病例。

诊断标准与关键数值

  • 四位专家对40个模拟临床病例的平均评分为4.17±0.65,中位数4.25(1-5分,5分代表完全同意CDSS工具)。
  • 四位评分者在75%的病例中完全同意系统推荐。
  • 采用二元同意/不同意变量时,四位专家对40个模拟病例评分的总体百分比一致性为77.28%。
  • 与ESR iGuide共160例次中出现20次不一致,其中7次来自两位放射科医生。
  • 一致性程度与适应证数量、患者年龄或性别之间无显著关系。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文写明这是一项试点研究,需在更大规模、最好是国家层面开展进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the acceptance and reliability of clinical decision support system (CDSS) imaging referral scores (ESR iGuide).

METHODS: A pilot study was conducted in a tertiary hospital. Four different experts were invited to rate 40 simulated clinical cases on a 5-level scale, for the level of agreement with the ESR iGuide's recommended procedures. In cases of disagreement, physicians were asked to indicate the reason. Descriptive measures were calculated for the level of agreement. We also explored the degree of agreement between four different specialists, and examined the cases in which clinicians disagreed with ESR iGuide best practice recommendations.

RESULTS: The mean rating of the four experts for the 40 clinical simulated cases was 4.17 ± 0.65, median 4.25 (on a scale of 1-5). All four raters totally agreed with the system recommendation in 75% of cases. No significant relationship was found between the degree of agreement and the number of indications and the patient's age or gender. In an optimistic scenario, using a binary agree/disagree variable, the Overall Percentage Agreement for the rating of the 40 simulated cases between the four experts was 77.28%. There were a total of 20 disagreements out of 160 cases with the ESR iGuide, of which 7 were among the two radiologists.

CONCLUSIONS: CDSS can be an effective tool for guiding the selection of appropriate imaging examinations, thus cutting costs due to unnecessary imaging scans. Since this is a pilot study, further research on a larger scale, preferably at national level, is required.

KEY POINTS: • The average of the mean rating of the four experts was 4.17 ± 0.65, median 4.25, on a scale of 1-5 where 5 represents total agreement with the CDSS tool. • In an optimistic scenario, using a binary agree/disagree variable, the Overall Percentage Agreement between the four experts was 77.28%. • Radiologists had fewer disagreements with the recommendations of the CDSS tool than other physicians, indicating a better fit of the support system to radiology experts' perspective.

来源:Eur Radiol,查看原文。版权归原作者所有。