文献速递腹部CTMR

以MRI为参考标准对频选择性非线性融合CT与常规CT检测局灶性肝脏病变的个体间比较

Interindividual Comparison of Frequency-Selective Nonlinear Blending to Conventional CT for Detection of Focal Liver Lesions Using MRI as the Reference Standard.
PubMed 文献 · AJR Am J Roentgenol · 2022-01-12

本回顾性研究纳入109例患者356个良恶性肝脏病变,以肝脏MRI为标准参考,比较频选择性非线性融合CT与常规增强CT对肝脏病变的检测效能。非线性融合CT的图像质量评分、病灶对比噪声比和检测敏感度均高于常规CT,且病灶大小测量的低估程度更小。

要点

  • 非线性融合CT检测肝脏病变的敏感度为86%,常规增强CT为76%。
  • 非线性融合CT病灶对比噪声比中位数12.49,常规增强CT为4.18(p < .001)。
  • 非线性融合CT病灶大小低估仅0.1 mm,常规增强CT低估2.5 mm。

核心结论

  • 频选择性非线性融合CT可提高图像质量和对比噪声比、增加大小测量精度,并提高肝脏病变检测敏感度。

研究设计与样本

  • 回顾性研究,纳入2012年1月至2017年12月间109例患者共356个肝脏病变(191个主要诊断、165个偶然发现),所有患者均行门静脉期增强CT和肝脏MRI,以MRI为标准参考;由5名阅片者分别进行图像质量评分、病变识别与分类、大小测量及ROI对比噪声比测量。

关键影像表现/征象

  • 非线性融合CT图像质量评分中位数4(第10-90百分位4-5),常规增强CT为2(第10-90百分位1-3)(p < .001)。
  • 常规增强CT读者间一致性ICC为0.81(95% CI 0.76-0.85),非线性融合CT为0.75(95% CI 0.69-0.79)。
  • 非线性融合CT肝脏病灶对比噪声比中位数12.49(第10-90百分位6.18-23.39),常规增强CT为4.18(第10-90百分位1.67-9.06)(p < .001)。
  • Bland-Altman分析显示病灶大小低估从常规增强CT的2.5 mm(SD 9.2 mm;95% CI 1.2-3.9 mm)降至非线性融合CT的0.1 mm(SD 3.9 mm;95% CI -0.68至0.46 mm),一致性相关系数0.99。

诊断标准与关键数值

  • 非线性融合CT检测肝脏病变的敏感度为86%,常规增强CT为76%。
  • 图像质量采用5点Likert量表评分,非线性融合CT中位评分4,常规增强CT中位评分2。

临床应用与阅片要点

  • 非线性融合CT可提高肝脏病灶的检出敏感度和对比噪声比,有助于病灶识别。
  • 非线性融合CT可减少病灶大小测量的低估,对考虑局部消融或肝移植的病例,病灶大小测量准确性更重要。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Diagnosing liver lesions is challenging. CT is used for primary diagnosis, but its contrast resolution is limited. Investigating methods to improve detection of liver lesions is important. OBJECTIVE. The purpose of this study was to evaluate the effect of frequency-selective nonlinear blending on the detectability of liver lesions on CT. METHODS. A retrospective search yielded 109 patients with 356 malignant and benign liver lesions (191 principally diagnosed, 165 incidental findings) who underwent contrast-enhanced CT (CECT) in the portal venous phase and liver MRI between January 2012 and December 2017. Nonlinear blending was applied to CECT examinations, and three blinded readers independently rated the quality (5-point Likert scale) of randomly presented images. Focal lesions (n = 356) were evaluated for lesion identification and categorization to assess sensitivity. For 191 lesions (primary diagnosis), two readers evaluated CECT and nonlinear blending CT to compare lesion size and the accuracy of subjective measurements. A fourth reader performed ROI measurements for calculation of contrast-to-noise ratio (CNR), and a fifth reader reviewed MRI as the standard of reference. Statistics included interobserver agreement, quantitative comparisons of CNR, lesion size, and subjective image analyses of image quality and sensitivity for detecting liver lesions. RESULTS. Three readers rated the image quality of nonlinear blending CT (rating, 4; 10th-90th percentiles, 4-5) higher than that of CECT (rating, 2; 10th-90th percentiles, 1-3) (p < .001). CECT had good interreader agreement (interclass correlation coefficient [ICC], 0.81; 95% CI, 0.76-0.85), as did nonlinear blending CT (ICC, 0.75; 95% CI, 0.69-0.79). The median CNR of liver lesions increased with nonlinear blending (CECT, 4.18 [10th-90th percentiles, 1.67-9.06]; nonlinear blending CT, 12.49 [10th-90th percentiles, 6.18-23.39]; p < .001). Bland-Altman analysis of lesion size showed a reduction in underestimation from 2.5 (SD, 9.2) mm (95% CI, 1.2-3.9 mm) with CECT to 0.1 (SD, 3.9) mm (95% CI, -0.68 to 0.46 mm) for nonlinear blending CT (concordance correlation coefficient, 0.99). Sensitivity for detecting liver lesions increased to 86% for nonlinear blending CT. The sensitivity of CECT was 76%. CONCLUSION. Frequency-selective nonlinear blending in CECT increases image quality and CNR, increases the precision of size measurement, and increases sensitivity for detecting liver lesions. CLINICAL IMPACT. Use of nonlinear blending CT improves liver lesion detection and increases the accuracy of lesion size measurement, which is important when local ablation or liver transplant is being considered.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Bongers, Walter, Fritz, et al. Interindividual Comparison of Frequency-Selective Nonlinear Blending to Conventional CT for Detection of Focal Liver Lesions Using MRI as the Reference Standard. AJR Am J Roentgenol. 2022. PMID: 35018796. doi:10.2214/AJR.21.26922

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。