文献速递腹部技术与安全CT

优化腹部多期CT扫描时机:采用个体化触发后延迟的团注跟踪技术

Optimize scan timing in abdominal multiphase CT: Bolus tracking with an individualized post-trigger delay.
PubMed 文献 · Eur J Radiol · 2021-12-31

本研究对104例接受腹部多期CT的患者进行头对头比较,分别采用个体化触发后延迟(A组)与固定11秒触发后延迟(B组)的团注跟踪策略。动脉期A组图像衰减更高,肝、胰、门静脉对比噪声比显著高于B组,而两组主观图像质量和诊断信心相似。

要点

  • 动脉期个体化触发后延迟较固定11秒延迟可获得更高的器官和血管强化程度。
  • 动脉期A组肝、胰、门静脉对比噪声比显著高于B组,信噪比两组相似。
  • 两组整体主观图像质量和诊断信心无显著差异。

核心结论

  • 与固定触发后延迟相比,采用个体化触发后延迟可在不损害诊断质量的前提下优化腹部多期CT动脉期的客观图像质量。

研究设计与样本

  • 头对头比较研究,纳入104例患者,分为个体化触发后延迟组(A组)和固定11秒触发后延迟组(B组),两组CT扫描参数和对比剂方案一致,比较定量参数和定性视觉参数,采用Mann-Whitney U检验、独立样本t检验和Kappa分析评估两名放射科医师之间的一致性。

关键影像表现/征象

  • 动脉期A组图像提供更高的衰减(P ≤ 0.001)。
  • 动脉期两组肝、胰、主动脉信噪比相似,但A组肝、胰、门静脉对比噪声比显著高于B组(所有P值 ≤ 0.002)。
  • 两组整体主观图像质量和诊断信心相似(P = 0.809;P = 0.768)。

临床应用与阅片要点

  • 采用团注跟踪行腹部多期CT时,个体化触发后延迟较固定11秒延迟可提高动脉期客观图像质量。
  • 个体化触发后延迟在提高客观图像质量的同时未降低主观图像质量和诊断信心。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To conduct a head-to-head comparison in terms of image quality and diagnostic confidence between an individualized post-trigger delay and a conventional fixed post-trigger delay in bolus tracking abdominal multiphase CT.

METHODS AND MATERIALS: Abdominal multiphase CT was performed in 104 patients with either of the two bolus tracking strategies: an individualized post-trigger delay (group A) and fixed post-trigger delay of 11 s (group B). All CT scan parameters and contrast media protocol parameters were consistent between the two groups. Quantitative parameters (organs and blood vessels enhancement, image noise, signal-to-noise ratios [SNRs] and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (overall image quality and diagnostic confidence) were compared. Quantitative and qualitative image quality for the two groups were compared using the Mann-Whitney U and independent sample t test. Degrees of agreement between two radiologists were evaluated using the Kappa analysis.

RESULTS: In the arterial phase (AP), images of group A provided higher attenuation (P ≤ 0.001). Although SNRs of liver, pancreas and aorta were similar in AP between the two groups, CNRs of liver, pancreas and portal vein in group A were significantly higher than those in group B (all P values ≤ 0.002). The overall subjective image quality and diagnostic confidence between the two groups were similar (P = 0.809; P = 0.768).

CONCLUSION: Compared to a fixed post-trigger delay using bolus tracking, application of an individualized post-trigger delay can optimize the objective image quality in arterial phase without compromising diagnostic quality in abdominal multiphase CT.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yu, Lin, Lu, et al. Optimize scan timing in abdominal multiphase CT: Bolus tracking with an individualized post-trigger delay. Eur J Radiol. 2021. PMID: 35021118. doi:10.1016/j.ejrad.2021.110139

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。