数字乳腺断层合成与数字乳腺X线摄影的召回率及假阳性率随判读时间与判读者经验的变化

Digital Breast Tomosynthesis and Digital Mammography Recall and False-Positive Rates by Time of Day and Reader Experience.
PubMed 文献 · Radiology · 2022-01-11

该回顾性研究分析2018年1月至2019年12月12个社区放射学站点18名放射科医生判读的97 671例筛查乳腺X线摄影(40 220例DBT,57 451例DM),发现DM与DBT的总体召回率(10.2% vs 9.0%,P = .006)和假阳性率(9.8% vs 8.6%,P = .004)不同;经验≤5年的放射科医生使用DBT时每迟1小时判读召回 odds 增加11.5%(OR = 1.12,P = .01),而DM无此发现(OR = 1.09,P = .06),两者不同(P = .02);经验>5年者DBT(OR = 1.02,P = .27)和DM(OR = 1.0,P = .80)均未观察到召回增加,且两者无差异(P = .13)。

要点

  • DBT筛查的总体召回率和假阳性率均低于DM(召回率9.0% vs 10.2%,P = .006;假阳性率8.6% vs 9.8%,P = .004)。
  • 经验≤5年的放射科医生使用DBT时,每迟1小时判读召回 odds 增加11.5%(OR = 1.12,P = .01)。
  • 经验>5年的放射科医生使用DBT或DM时均未观察到召回率随判读时间增加(DBT OR = 1.02,P = .27;DM OR = 1.0,P = .80)。

核心结论

  • 当经验较少的放射科医生在一天中较晚时间判读筛查DBT图像时,患者被召回的 likelihood 更高。

研究设计与样本

  • 回顾性研究,分析2018年1月至2019年12月12个社区放射学站点18名放射科医生判读的97 671例筛查乳腺X线摄影(40 220例DBT,57 451例DM),采用广义线性混合模型(二项分布、三明治估计,观察值按放射科医生嵌套)分析判读时间、图像类型与召回及假阳性/真阳性的关联。

诊断标准与关键数值

  • DM与DBT总体召回率分别为10.2%和9.0%,两者不同(P = .006)。
  • DM与DBT假阳性率分别为9.8%和8.6%,两者不同(P = .004)。
  • 经验≤5年组使用DBT时每迟1小时判读召回 OR = 1.12(P = .01),DM OR = 1.09(P = .06),两者不同(P = .02)。
  • 经验>5年组使用DBT时每迟1小时判读召回 OR = 1.02(P = .27),DM OR = 1.0(P = .80),两者无差异(P = .13)。

临床应用与阅片要点

  • 原文结论提示经验较少的放射科医生在一天较晚时间判读DBT图像时患者召回 likelihood 更高;原文未据此给出具体阅片安排或报告建议。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Digital breast tomosynthesis (DBT) image interpretation might be more cognitively demanding than interpretation of digital mammography (DM) images. The time of day of interpretation might affect recall and false-positive (FP) rates, especially for DBT. Purpose To determine whether recall and FP rates vary by time of day of interpretation for screening mammography for breast cancer performed with DM and DBT. Materials and Methods This is a retrospective study examining 97 671 screening mammograms interpreted by 18 radiologists between January 2018 and December 2019 at one of 12 community radiology sites. The association between the time of day of interpretation, the type of image interpreted (DM vs DBT), and radiologist experience (≤5 posttraining years vs >5 posttraining years) and the likelihood of a patient being recalled from screening mammography and the likelihood of whether the interpretation was FP or true positive were analyzed. Analyses were conducted using generalized linear mixed modeling with a binary distribution and sandwich estimation where observations were nested by radiologist. Results Screening mammograms interpreted by 18 radiologists were reviewed (40 220 DBTs, 57 451 DMs). Nine radiologists had 5 or fewer posttraining years of experience, and nine had more than 5 posttraining years of experience. The overall recall rates for DM (10.2%) and DBT (9.0%) were different (P = .006); FP rate also differed (9.8% DM, 8.6% DBT; P = .004). For radiologists with 5 or fewer posttraining years of experience, odds of recall increased 11.5% (odds ratio [OR] = 1.12, P = .01) with every hour when using DBT, but this was not found for DM (OR = 1.09, P = .06); DBT and DM were different (OR = 1.12 vs 1.09, P = .02). For radiologists with more than 5 posttraining years of experience, no evidence of increase in recall was observed for DBT (OR = 1.02, P = .27) or DM (OR = 1.0, P = .80), and there was no evidence that these were different (OR = 1.02 vs 1.0, P = .13). Conclusion Patients were more likely to be recalled when their screening digital breast tomosynthesis images were interpreted later in the day by less-experienced radiologists. © RSNA, 2022 Online supplemental material is available for this article.