文献速递胸部DRCT

运用暗场胸部X线摄影对肺气肿进行定性和定量评估

Qualitative and Quantitative Assessment of Emphysema Using Dark-Field Chest Radiography.
PubMed 文献 · Radiology · 2022-01-11

这项前瞻性研究纳入83名受试者,采用临床暗场胸部X线摄影原型机同时采集衰减图像和暗场图像,并与CT对照。肺气肿患者暗场信号强度降低且不均匀,暗场系数与CT肺气肿指数呈负相关(r=-0.54,P<.001),检测轻度肺气肿的AUC为0.79。作者认为该技术有潜力作为肺部疾病评估的诊断工具。

要点

  • 肺气肿患者暗场胸片表现为暗场信号强度降低且不均匀,局灶信号丢失位置与CT肺气肿区对应良好。
  • 暗场系数与CT肺气肿指数呈负相关(r=-0.54,P<.001),可用于定量评估。
  • 检测轻度肺气肿的ROC曲线下面积为0.79。

核心结论

  • 肺气肿导致暗场胸片信号强度降低,该技术有潜力作为肺部疾病评估的诊断工具。

研究设计与样本

  • 前瞻性研究,2018年10月至2020年10月,纳入83名年龄至少18岁、因临床指征接受胸部CT的受试者,使用临床暗场胸部X线摄影原型机同时采集衰减X线片和暗场胸片,以CT为参考标准。

关键影像表现/征象

  • 与健康受试者相比,肺气肿患者暗场胸片信号强度降低且不均匀,暗场图像上局灶信号强度丢失的位置与CT图像上的肺气肿区域对应良好。

诊断标准与关键数值

  • 暗场系数与CT肺气肿指数呈负相关(r=-0.54,P<.001);Fleischner学会肺气肿分级为轻度、中度、融合性或晚期破坏性肺气肿的受试者暗场系数低于无肺气肿者(例如融合性或晚期破坏性肺气肿者为1.3 m-1 ± 0.6,无肺气肿者为2.6 m-1 ± 0.4,P<.001);检测轻度肺气肿的ROC曲线下面积为0.79。

临床应用与阅片要点

  • 阅片时可关注暗场胸片上信号强度降低且不均匀的区域,并与CT肺气肿区域对照;暗场系数可用于定量评估肺气肿程度,检测轻度肺气肿的AUC为0.79。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Dark-field chest radiography allows for assessment of lung alveolar structure by exploiting wave optical properties of x-rays. Purpose To evaluate the qualitative and quantitative features of dark-field chest radiography in participants with pulmonary emphysema as compared with those in healthy control subjects. Materials and Methods In this prospective study conducted from October 2018 to October 2020, participants aged at least 18 years who underwent clinically indicated chest CT were screened for participation. Inclusion criteria were an ability to consent to the procedure and stand upright without help. Exclusion criteria were pregnancy, serious medical conditions, and any lung condition besides emphysema that was visible on CT images. Participants were examined with a clinical dark-field chest radiography prototype that simultaneously acquired both attenuation-based radiographs and dark-field chest radiographs. Dark-field coefficients were tested for correlation with each participant's CT-based emphysema index using the Spearman correlation test. Dark-field coefficients of adjacent groups in the semiquantitative Fleischner Society emphysema grading system were compared using a Wilcoxon Mann-Whitney U test. The capability of the dark-field coefficient to enable detection of emphysema was evaluated with receiver operating characteristics curve analysis. Results A total of 83 participants (mean age, 65 years ± 12 [standard deviation]; 52 men) were studied. When compared with images from healthy participants, dark-field chest radiographs in participants with emphysema had a lower and inhomogeneous dark-field signal intensity. The locations of focal signal intensity loss on dark-field images corresponded well with emphysematous areas found on CT images. The dark-field coefficient was negatively correlated with the quantitative CT-based emphysema index (r = -0.54, P < .001). Participants with Fleischner Society grades of mild, moderate, confluent, or advanced destructive emphysema exhibited a lower dark-field coefficient than those without emphysema (eg, 1.3 m-1 ± 0.6 for participants with confluent or advanced destructive emphysema vs 2.6 m-1 ± 0.4 for participants without emphysema; P < .001). The area under the receiver operating characteristic curve for detection of mild emphysema was 0.79. Conclusion Pulmonary emphysema leads to reduced signal intensity on dark-field chest radiographs, showing the technique has potential as a diagnostic tool in the assessment of lung diseases. © RSNA, 2022 See also the editorial by Hatabu and Madore in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Urban, Gassert, Frank, et al. Qualitative and Quantitative Assessment of Emphysema Using Dark-Field Chest Radiography. Radiology. 2022. PMID: 35014904. doi:10.1148/radiol.212025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。