文献速递神经MR

合成FLAIR替代真实FLAIR序列在急性缺血性卒中中的应用

Synthetic FLAIR as a Substitute for FLAIR Sequence in Acute Ischemic Stroke.
PubMed 文献 · Radiology · 2022-01-11

本研究回顾性纳入2002年1月至2019年5月连续急性缺血性卒中患者,训练生成对抗网络以DWI为输入合成FLAIR,在测试集(282次扫描)中比较合成与真实FLAIR对DWI-FLAIR不匹配的评估及识别4.5小时内卒中的诊断效能,结果显示两者诊断效能相似,合成FLAIR可能加速MRI流程。

要点

  • 合成FLAIR与真实FLAIR对DWI-FLAIR不匹配的观察者间一致性均为κ=0.80。
  • 两种FLAIR共识后一致性的κ=0.88(95%CI:0.82,0.93),几乎完美。
  • 识别4.5小时内卒中的敏感度与特异度在两种FLAIR间无显著差异。

核心结论

  • 合成FLAIR在描绘DWI-FLAIR不匹配和辅助识别早期急性缺血性卒中方面诊断效能与真实FLAIR相似,可能加速MRI流程。

研究设计与样本

  • 回顾性研究,纳入861例患者共1416次MRI扫描,训练集1134次、测试集282次,训练生成对抗网络以DWI(b=0-1000 sec/mm2)为输入生成合成FLAIR,由4名独立阅片者评估DWI-FLAIR不匹配。

关键影像表现/征象

  • DWI-FLAIR不匹配评估的观察者间重现性在真实FLAIR与合成FLAIR均为κ=0.80(95%CI:0.74,0.87)。
  • 真实与合成FLAIR共识后一致性的κ=0.88(95%CI:0.82,0.93),几乎完美。

诊断标准与关键数值

  • 识别4.5小时内卒中的敏感度:真实FLAIR 107/131(82%) vs 合成FLAIR 111/131(85%),P=0.2。
  • 识别4.5小时内卒中的特异度:真实FLAIR 96/104(92%) vs 合成FLAIR 96/104(92%),P>0.99。

临床应用与阅片要点

  • 合成FLAIR可能作为真实FLAIR的替代用于评估DWI-FLAIR不匹配,以缩短MRI扫描时间。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background In acute ischemic stroke (AIS), fluid-attenuated inversion recovery (FLAIR) is used for treatment decisions when onset time is unknown. Synthetic FLAIR could be generated with deep learning from information embedded in diffusion-weighted imaging (DWI) and could replace acquired FLAIR sequence (real FLAIR) and shorten MRI duration. Purpose To compare performance of synthetic and real FLAIR for DWI-FLAIR mismatch estimation and identification of patients presenting within 4.5 hours from symptom onset. Materials and Methods In this retrospective study, all pretreatment and early follow-up (<48 hours after symptom onset) MRI data sets including DWI (b = 0-1000 sec/mm2) and FLAIR sequences obtained in consecutive patients with AIS referred for reperfusion therapies between January 2002 and May 2019 were included. On the training set (80%), a generative adversarial network was trained to produce synthetic FLAIR with DWI as input. On the test set (20%), synthetic FLAIR was computed without real FLAIR knowledge. The DWI-FLAIR mismatch was evaluated on both FLAIR data sets by four independent readers. Interobserver reproducibility and DWI-FLAIR mismatch concordance between synthetic and real FLAIR were evaluated with κ statistics. Sensitivity and specificity for identification of AIS within 4.5 hours were compared in patients with known onset time by using McNemar test. Results The study included 1416 MRI scans (861 patients; median age, 71 years [interquartile range, 57-81 years]; 375 men), yielding 1134 and 282 scans for training and test sets, respectively. Regarding DWI-FLAIR mismatch, interobserver reproducibility was substantial for real and synthetic FLAIR (κ = 0.80 [95% CI: 0.74, 0.87] and 0.80 [95% CI: 0.74, 0.87], respectively). After consensus, concordance between real and synthetic FLAIR was almost perfect (κ = 0.88; 95% CI: 0.82, 0.93). Diagnostic value for identifying AIS within 4.5 hours did not differ between real and synthetic FLAIR (sensitivity: 107 of 131 [82%] vs 111 of 131 [85%], P = .2; specificity: 96 of 104 [92%] vs 96 of 104 [92%], respectively, P > .99). Conclusion Synthetic fluid-attenuated inversion recovery (FLAIR) had diagnostic performances similar to real FLAIR in depicting diffusion-weighted imaging-FLAIR mismatch and in helping to identify early acute ischemic stroke, and it may accelerate MRI protocols. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Carroll and Hurley in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Benzakoun, Deslys, Legrand, et al. Synthetic FLAIR as a Substitute for FLAIR Sequence in Acute Ischemic Stroke. Radiology. 2022. PMID: 35014901. doi:10.1148/radiol.211394

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。