剪切波弹性成像与脉冲多普勒在乳腺病变中的应用:诊断效能相似且硬度与血流阻力正相关

Shear wave elastography and pulsed doppler for breast lesions: Similar diagnostic performance and positively correlated stiffness and blood flow resistance.
PubMed 文献 · Eur J Radiol · 2022-01-04

纳入79例乳腺病变患者,比较剪切波弹性成像(SWE)与脉冲多普勒超声的诊断效能,并分析SWE定量参数与多普勒参数的相关性。结果显示两者诊断效能相似,Esd与PI的AUC分别为0.877和0.871;SWE参数与PI、RI呈中度正相关,尤其在恶性病变中。

要点

  • SWE与脉冲多普勒对乳腺病变诊断效能相似,Esd与PI的AUC分别为0.877和0.871。
  • SWE参数与血流阻力指标呈中度正相关,恶性病变中Emax和Esd与PI或RI显著相关。
  • 良性病变中SWE参数与多普勒参数无显著相关性。

核心结论

  • SWE与脉冲多普勒超声对乳腺病变诊断效能相似,SWE参数与多普勒参数显著相关,尤其在恶性病变中,提示弹性特征与血管特征可能存在关联。

研究设计与样本

  • 纳入79例患者共79个乳腺病变,均在一周内接受空心针活检或手术,获取SWE参数(Emax、Emean、Emin、Esd)和多普勒参数(RI、PI、PSV、EDV)进行统计分析。

诊断标准与关键数值

  • Esd与PI的AUC分别为0.877和0.871,在SWE和血管参数中分别最佳。
  • Emax与PI中度相关(P=0.000,r=0.552),与RI中度相关(P=0.000,r=0.544)。
  • Esd与PI中度相关(P=0.000,r=0.567),与RI中度相关(P=0.000,r=0.546)。

临床应用与阅片要点

  • SWE与脉冲多普勒对乳腺病变诊断效能相似,SWE参数与血流阻力指标正相关,在恶性病变中相关性更明显。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the diagnostic performance of shear wave elastography (SWE) and pulsed Doppler ultrasound in breast lesions, and to explore whether the quantitative SWE parameters correlated with pulsed Doppler ultrasound parameters.

MATERIALS AND METHODS: Seventy-nine patients with 79 breast lesions who had undergone conventional ultrasound, pulsed Doppler ultrasound and SWE examination were included. All of them underwent core needle biopsy or surgery within one week. Parameters including Emax (the maximum elastic modulus), Emean (mean elastic modulus), Emin (minimum elastic modulus), Esd (elastic modulus standard deviation), and RI (resistive index), PI (pulsatility index), PSV (peak systolic velocity) and EDV (end diastolic velocity) were obtained for statistical analysis.

RESULTS: Almost all SWE parameters were significantly different between benign and malignant breast lesions (P<0.05). There was no significant difference between Esd and PI (P>0.05), which had the best AUC among SWE and vascular parameters respectively (0.877 vs. 0.871). Emax showed a moderate correlation with PI (P = 0.000, r = 0.552) and RI (P = 0.000, r = 0.544), and Esd moderately correlated with PI (P = 0.000, r = 0.567) and RI (P = 0.000, r = 0.546). For the benign group, no parameters showed any significant correlation (P>0.05), while for the malignant group, Emax and Esd also significantly correlated with PI or RI.

CONCLUSIONS: SWE and pulsed Doppler ultrasound had similar diagnostic efficacy for breast lesions. SWE and pulsed Doppler parameters were significantly correlated in breast lesions, especially in malignant ones, indicating the potential association between elastographic and vascular characteristics of breast tumors.

来源:Eur J Radiol,查看原文。版权归原作者所有。