128排多探测器CT双排除技术评估急性胸痛
本研究评估128排多探测器CT双排除技术同步评估急性非特异性胸痛患者主动脉和冠状动脉的可行性与图像质量。68例患者行心电门控冠状动脉CT后接非心电门控腹部CT,主动脉和冠状动脉平均衰减分别>350 HU和>330 HU,平均对比剂用量69.5±12.5 ml。作者认为该技术用标准对比剂体积(约70 ml)对疑似急性主动脉综合征或急性冠状动脉综合征的急性胸痛评估有用,在维持平均CT衰减>330 HU的同时准确且安全。
要点
- 双排除技术可同步评估主动脉和冠状动脉,主动脉平均衰减>350 HU,冠状动脉>330 HU。
- 平均对比剂体积为69.5±12.5 ml,作者称标准体积约70 ml。
- 主动脉图像质量观察者间一致性为完美,冠状动脉为显著一致。
核心结论
- 作者认为,使用标准体积(约70 ml)对比剂的双排除技术对疑似急性主动脉综合征或急性冠状动脉综合征的急性胸痛评估有用,在维持主动脉和冠状动脉平均CT衰减>330 HU的同时准确且安全。
研究设计与样本
- 研究纳入68例急性非特异性胸痛患者,行心电门控冠状动脉CT后接非心电门控腹部CT,计算主动脉和冠状动脉与邻近血管周围脂肪组织的对比噪声比和信噪比,记录剂量长度乘积,两名盲法读者分别用两点法和四点法分级主动脉和冠状动脉图像质量,并独立分析各冠状动脉血管的狭窄严重程度。
关键影像表现/征象
- 主动脉平均衰减>350 HU,冠状动脉平均衰减>330 HU。
- 主动脉图像质量观察者间一致性为完美,冠状动脉图像质量观察者间一致性为显著一致。
- 所有冠状动脉狭窄严重程度观察的观察者间一致性几乎完美。
临床应用与阅片要点
- 作者认为该双排除技术对疑似急性主动脉综合征或急性冠状动脉综合征的急性胸痛评估有用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the feasibility and image quality of the double rule-out (DRO) technique using 128-row multidetector computed tomography (CT) for simultaneous evaluation of the aorta and coronary arteries in patients with acute non-specific chest pain.
MATERIALS AND METHODS: Sixty-eight patients underwent electrocardiography (ECG)-gated coronary CT followed by non-ECG-gated abdominal CT. The contrast-to-noise ratio and signal-to-noise ratio between the vessels and adjacent perivascular fat tissue were calculated for both the aorta and coronary arteries. Dose-length products were recorded. Two blinded readers graded the image quality of the aorta and coronary arteries on a two-point and a four-point scale, respectively. In addition, the severity of coronary stenosis was independently analysed for each coronary vessel.
RESULTS: The average attenuation was more than 350 HU for the aorta and >330 HU for the coronary arteries. The average (±standard deviation) volume of contrast media was 69.5 ± 12.5 ml. Interobserver agreement on the image quality of aortic and coronary data sets was perfect and substantial, respectively. There was almost perfect interobserver agreement for the all observations of the severity of coronary stenosis.
CONCLUSION: The DRO technique with a standard volume (approximately 70 ml) of contrast media is useful for acute chest pain evaluation in patients suspected of having acute aortic syndrome or acute coronary syndrome. It is also accurate and safe while maintaining the average CT attenuation of the aorta and coronary arteries >330 HU.
引用
- Denewar, Urano, Ozawa, et al. Double rule-out technique for evaluation of acute chest pain using 128-row multidetector CT. Clin Radiol. 2022. PMID: 35000763. doi:10.1016/j.crad.2021.12.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。