原发性开角型青光眼患者中提示阿尔茨海默病的MRI表现:基于快速3D T1 spoiled gradient echo序列的单序列分析
本研究纳入50例原发性开角型青光眼患者与50例正常对照,行脑MRI T1磁化准备快速梯度回波序列,采用MTA与PCA/Koedam评分比较两组内侧颞叶与顶叶萎缩。结果显示POAG组PCA评分与对照组有统计学差异(P=0.026),MTA评分无统计学差异(P=0.58)。作者提示POAG与PCA评分可能存在相关性,该评分方法或可用于POAG患者的临床诊断与监测。
要点
- POAG组与对照组的PCA评分存在统计学差异(P=0.026)。
- POAG组与对照组的MTA评分无统计学差异(P=0.58)。
- 作者提示AD所用评分方法也可能用于POAG的诊断与监测。
核心结论
- 本研究提示POAG与PCA评分存在相关性,AD所用的评分方法可能应用于POAG患者的临床诊断与监测。
研究设计与样本
- 研究纳入50例POAG患者与50例正常受试者,行脑MRI T1磁化准备快速梯度回波序列,采用MTA与PCA/Koedam评分系统评估内侧颞叶与顶叶萎缩。
关键影像表现/征象
- 采用MTA与PCA/Koedam评分系统在T1磁化准备快速梯度回波序列上评估内侧颞叶与顶叶萎缩。
- POAG组PCA评分与健康对照组有统计学差异(P=0.026)。
- POAG组MTA评分与健康对照组无统计学差异(P=0.58)。
诊断标准与关键数值
- 采用内侧颞叶萎缩(MTA)评分与后皮质萎缩(PCA)/Koedam评分系统评估萎缩。
- POAG组与对照组PCA评分比较P=0.026。
- POAG组与对照组MTA评分比较P=0.58。
临床应用与阅片要点
- 作者提示,AD所用的评分方法也可能应用于POAG的诊断与监测。
- 作者指出,脑MRI快速容积T1 spoiled gradient echo序列可能应用于POAG评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Primary open-angle glaucoma (POAG) is a degenerative optic neuropathy disease which has somewhat similar pathophysiology to Alzheimer's disease (AD). This study aims to determine the presence of medial temporal atrophy and parietal lobe atrophy in patients with POAG compared to normal controls using medial temporal atrophy (MTA) scoring and posterior cortical atrophy (PCA) scoring system on T1 magnetization-prepared rapid gradient-echo.
METHODS: 50 POAG patients and 50 normal subjects were recruited and an MRI brain with T1-magnetization-prepared rapid gradient-echo was performed. Medial temporal lobe and parietal lobe atrophy were by MTA and PCA/Koedam scoring. The score of the PCA and MTA were compared between the POAG group and the controls.
RESULTS: There was a significant statistical difference between PCA score in POAG and the healthy control group (p-value = 0.026). There is no statistical difference between MTA score in POAG compared to the healthy control group (p-value = 0.58).
CONCLUSION: This study suggests a correlation between POAG and PCA score. Potential application of this scoring method in clinical diagnosis and monitoring of POAG patients.
ADVANCES IN KNOWLEDGE: The scoring method used in AD may also be applied in the diagnosis and monitoring of POAGMRI brain, specifically rapid volumetric T1 spoiled gradient echo sequence, may be applied in POAG assessment.
引用
- Hanafiah, Johari, Ab Mumin, et al. MRI findings suggestive of Alzheimer's disease in patients with primary open angle glaucoma - a single sequence analysis using rapid 3D T1 spoiled gradient echo. Br J Radiol. 2022. PMID: 35007174. doi:10.1259/bjr.20210857
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。