文献速递神经MR

胶质母细胞瘤MR弹性成像显示组织硬度降低与脑血流量增加相关

Decreased tissue stiffness in glioblastoma by MR elastography is associated with increased cerebral blood flow.
PubMed 文献 · Eur J Radiol · 2021-12-29

研究纳入10例胶质母细胞瘤患者和17名健康受试者,采用MR弹性成像、灌注和扩散MRI测量肿瘤强化区、坏死区、水肿区及正常脑组织的硬度G'与黏度G''、脑血流量、表观扩散系数和各向异性分数。结果显示强化肿瘤硬度G'和黏度G''较正常白质分别低13%和37%,坏死区较强化肿瘤分别低8%和6%,将MRE测量加入模型可改善脑血流量预测,组织越硬对应灌注越低。

要点

  • 强化肿瘤G'和G''较正常白质分别低13%和37%(P<0.01)。
  • 坏死区G'和G''较强化肿瘤分别低8%和6%(P<0.05)。
  • 加入MRE测量可改善脑血流量预测(P<0.01),组织越硬灌注越低。

核心结论

  • 将MRE测量纳入统计模型有助于预测灌注,组织越硬对应脑血流量越低。

研究设计与样本

  • 研究论文,纳入10例胶质母细胞瘤患者和17名健康受试者,采用MR弹性成像、灌注和扩散MRI,在患者强化肿瘤、坏死、水肿、灰质和白质及健康受试者灰质和白质中测量G'、G''、CBF、ADC和FA,并用回归分析以ADC、FA、G'和G''预测CBF。

关键影像表现/征象

  • 强化肿瘤中位G'和G''较正常白质分别低13%和37%(P<0.01)。
  • 坏死区中位G'和G''较强化肿瘤分别低8%和6%(P<0.05)。
  • 肿瘤呈现患者间和患者内异质性。
  • 从肿瘤核心向外测量值接近正常组织,但正常表现组织区域仍存在异常组织特性。

诊断标准与关键数值

  • 线性模型和随机森林模型中加入MRE测量后CBF预测改善(P<0.01)。

临床应用与阅片要点

  • 强化肿瘤硬度G'和G''较正常白质分别低13%和37%(P<0.01)。
  • 坏死区硬度G'和G''较强化肿瘤分别低8%和6%(P<0.05)。
  • 肿瘤呈现患者间和患者内异质性,从肿瘤核心向外测量值接近正常组织但正常表现组织区域仍存在异常组织特性。
  • 线性模型和随机森林模型中加入MRE测量后CBF预测改善(P<0.01),组织越硬对应灌注越低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Understanding how mechanical properties relate to functional changes in glioblastomas may help explain different treatment response between patients. The aim of this study was to map differences in biomechanical and functional properties between tumor and healthy tissue, to assess any relationship between them and to study their spatial distribution.

METHODS: Ten patients with glioblastoma and 17 healthy subjects were scanned using MR Elastography, perfusion and diffusion MRI. Stiffness and viscosity measurements G' and G'', cerebral blood flow (CBF), apparent diffusion coefficient (ADC) and fractional anisotropy (FA) were measured in patients' contrast-enhancing tumor, necrosis, edema, and gray and white matter, and in gray and white matter for healthy subjects. A regression analysis was used to predict CBF as a function of ADC, FA, G' and G''.

RESULTS: Median G' and G'' in contrast-enhancing tumor were 13% and 37% lower than in normal-appearing white matter (P < 0.01), and 8% and 6% lower in necrosis than in contrast-enhancing tumor, respectively (P < 0.05). Tumors showed both inter-patient and intra-patient heterogeneity. Measurements approached values in normal-appearing tissue when moving outward from the tumor core, but abnormal tissue properties were still present in regions of normal-appearing tissue. Using both a linear and a random-forest model, prediction of CBF was improved by adding MRE measurements to the model (P < 0.01).

CONCLUSIONS: The inclusion of MRE measurements in statistical models helped predict perfusion, with stiffer tissue associated with lower perfusion values.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Fløgstad Svensson, Fuster-Garcia, Latysheva, et al. Decreased tissue stiffness in glioblastoma by MR elastography is associated with increased cerebral blood flow. Eur J Radiol. 2021. PMID: 35007982. doi:10.1016/j.ejrad.2021.110136

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。