深度学习重建联合锐化滤波器对子宫单次激发快速自旋回波T2加权磁共振成像的影响
研究纳入50例连续接受盆腔磁共振成像的患者,比较PROPELLER与SSFSE序列(平均扫描时间分别为204秒和22秒),并重建常规、深度学习及深度学习联合锐化滤波三种SSFSE图像。结果显示SSFSE-DLF图像质量与PROPELLER相当或显著更高,联合深度学习与锐化滤波可将SSFSE子宫图像质量提升至PROPELLER序列水平。
要点
- SSFSE-DLF图像质量与PROPELLER相当或显著更高(平均AUCVGC 0.69,P<0.01)。
- SSFSE-DL图像结合带与子宫肌层对比度显著低于其他序列(P<0.05)。
- SSFSE-DLF信噪比与PROPELLER等效,扫描时间22秒远短于204秒。
核心结论
- 联合深度学习与锐化滤波可显著提高子宫SSFSE图像质量至PROPELLER序列水平。
研究设计与样本
- 纳入50例连续接受盆腔磁共振成像的患者,采集4mm层厚矢状面T2WI,PROPELLER与SSFSE平均扫描时间分别为204秒和22秒,重建SSFSE-C、SSFSE-DL、SSFSE-DLF三种图像,由3名放射科医师独立评估图像质量。
关键影像表现/征象
- SSFSE-C信噪比显著低于PROPELLER图像(P<0.05)。
- SSFSE-DL信噪比显著高于PROPELLER图像(P<0.05)。
- SSFSE-DLF信噪比与PROPELLER图像等效。
- SSFSE-DL图像结合带与子宫肌层对比度显著低于其他序列(P<0.05)。
诊断标准与关键数值
- 与PROPELLER图像定性比较,SSFSE-DL伪影评分显著更高(P<0.01)。
- 与PROPELLER图像定性比较,SSFSE-DLF锐利度评分显著更高(P<0.01)。
- 与PROPELLER图像定性比较,SSFSE-C噪声评分显著更高(P<0.01)。
- 总体图像质量SSFSE-C平均AUCVGC为0.03(P<0.01),SSFSE-DL为0.23(P<0.01),均显著劣于PROPELLER。
- SSFSE-DLF总体图像质量平均AUCVGC为0.69,与PROPELLER等效或显著更高(P<0.01)。
临床应用与阅片要点
- 联合深度学习与锐化滤波的SSFSE序列可在22秒扫描时间内获得与204秒PROPELLER序列相当或更优的子宫T2WI图像质量。
- SSFSE-DL虽提高信噪比,但结合带与子宫肌层对比度显著降低,阅片时需注意。
- SSFSE-DLF信噪比与PROPELLER等效,且锐利度评分显著更高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aimed to evaluate the effects of deep learning (DL) reconstruction and a postprocessing sharpening filter on the image quality of single-shot fast spin-echo (SSFSE) T2-weighted imaging (T2WI) of the uterus.
MATERIALS AND METHODS: Fifty consecutive patients who underwent pelvic magnetic resonance imaging were included. Parasagittal T2WI with a slice thickness of 4 mm was obtained with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and SSFSE sequences (mean scan time, 204 and 22 seconds, respectively). The following 3 types of SSFSE images were reconstructed, and the signal-to-noise ratio (SNR) and tissue contrast were assessed: conventional reconstruction (SSFSE-C), DL reconstruction (SSFSE-DL), and DL with a sharpening filter (SSFSE-DLF). Three radiologists independently assessed image quality, and area under the visual grading characteristics curve (AUCVGC) analysis was performed to compare the SSFSE and PROPELLER images.
RESULTS: Compared with that of the PROPELLER images, the SNR of the SSFSE-C, SSFSE-DL, and SSFSE-DLF images was significantly lower (P < 0.05), significantly higher (P < 0.05), and equivalent, respectively. The SSFSE-DL images exhibited significantly lower contrast between the junctional zone and myometrium than those obtained with the other sequences (P < 0.05). In qualitative comparisons with the PROPELLER images, all 3 SSFSE sequences, SSFSE-DL, and SSFSE-DLF demonstrated significantly higher scores for artifacts, noise, and sharpness, respectively (P < 0.01). The overall image quality of SSFSE-C (mean AUCVGC, 0.03; P < 0.01) and SSFSE-DL (mean AUCVGC, 0.23; P < 0.01) was rated as significantly inferior, whereas that of SSFSE-DLF (mean AUCVGC, 0.69) was equivalent or significantly higher (P < 0.01).
CONCLUSION: Using a combination of DL and a sharpening filter markedly increases the image quality of SSFSE of the uterus to the level of the PROPELLER sequence.
引用
- Tsuboyama, Onishi, Nakamoto, et al. Impact of Deep Learning Reconstruction Combined With a Sharpening Filter on Single-Shot Fast Spin-Echo T2-Weighted Magnetic Resonance Imaging of the Uterus. Invest Radiol. 2022. PMID: 34999668. doi:10.1097/RLI.0000000000000847
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。