文献速递乳腺CTUS乳腺X线

乳腺手术中X线摄影、数字乳腺断层合成、显微CT和超声用于切缘评估的诊断准确性:系统评价与Meta分析

Diagnostic accuracy of radiography, digital breast tomosynthesis, micro-CT and ultrasound for margin assessment during breast surgery: A systematic review and meta-analysis.
PubMed 文献 · Acad Radiol · 2022-01-04

该系统评价与Meta分析纳入22篇文章共29种术中切缘评估的放射学方法,以组织学评估为参考标准,比较X线摄影、数字乳腺断层合成(DBT)、显微CT和超声的汇总敏感度与特异度。超声诊断性能最高(AUC 80%),X线摄影最低(AUC 60%),但研究间异质性高且亚组样本小,切缘评估的放射学方法仍需改进以可靠指导临床流程并避免再次手术。

要点

  • 超声汇总敏感度72%、特异度78%、AUC 80%,在四种方法中诊断性能最高。
  • X线摄影汇总敏感度52%、特异度77%、AUC 60%,在四种方法中诊断性能最低。
  • DBT汇总敏感度67%、特异度76%、AUC 76%;显微CT汇总敏感度68%、特异度69%、AUC 72%。

核心结论

  • 超声在术中切缘评估中诊断性能最高,X线摄影最低;但研究间异质性高且亚组样本小,切缘评估的放射学方法仍需进一步改进以可靠指导临床流程并避免再次手术。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed、Embase、Cochrane Library、Scopus和Web of Science,初筛798条唯一记录,最终纳入22篇文章共29种放射学影像方法,以组织学评估为参考标准,采用QUADAS-2工具进行质量评价,并使用双变量随机效应模型计算汇总敏感度和特异度。

诊断标准与关键数值

  • X线摄影:汇总敏感度52%、特异度77%、AUC 60%。
  • DBT:汇总敏感度67%、特异度76%、AUC 76%。
  • 显微CT:汇总敏感度68%、特异度69%、AUC 72%。
  • 超声:汇总敏感度72%、特异度78%、AUC 80%。

局限性

  • 研究间异质性高且亚组样本小。
  • 纳入研究对再次手术率的报告不充分。
  • 切缘评估的放射学方法仍需进一步改进以提供可靠的临床流程指导并避免再次手术。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Achieving adequate resection margins in breast conserving surgery is challenging and often demands more than one surgical procedure. We evaluated pooled diagnostic sensitivity, and specificity of radiological methods for intraoperative margin assessment and their impact on repeat surgery rate.

MATERIALS AND METHODS: We included studies using radiography, digital breast tomosynthesis (DBT), micro-CT, and ultrasound for intraoperative margin assessment with the histological assessment as the reference method. A systematic search was performed in PubMed, Embase, Cochrane Library, Scopus, and Web of Science. Two investigators screened the studies for eligibility criteria and extracted data of the included studies independently. The quality assessment on diagnostic accuracy studies (QUADAS)-2 tool was used. A bivariate random effect model was used to obtained pooled sensitivity and specificity of the index tests in the meta-analysis.

RESULTS: The systematic search resulted in screening of 798 unique records. Twenty-two articles with 29 radiological imaging methods were selected for meta-analysis. Pooled sensitivity and specificity and area under the curve were calculated for each of the 4 subgroups in the meta-analysis respectively: Radiography; 52%, 77%, 60%, DBT; 67%, 76%, 76%, micro-CT; 68%, 69%, 72%, and ultrasound; 72%, 78%, 80%. The repeat surgery rate was poorly reported in the included studies.

CONCLUSION: Ultrasound showed the highest and radiography the lowest diagnostic performance for intraoperative margin assessment. However, the heterogeneity between studies was high and the subgroups small. The radiological methods for margin assessment need further improvement to provide reliable guidance in the clinical workflow and to prevent repeat surgeries.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Manhoobi, Bodilsen, Nijkamp, et al. Diagnostic accuracy of radiography, digital breast tomosynthesis, micro-CT and ultrasound for margin assessment during breast surgery: A systematic review and meta-analysis. Acad Radiol. 2022. PMID: 34996687. doi:10.1016/j.acra.2021.12.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。