文献速递神经外周血管USDSA

无创检测弥漫性颅内椎基底动脉狭窄:与数字减影血管造影的前瞻性比较

Non-invasive Detection of Diffuse Intracranial Vertebrobasilar Artery Stenosis: A Prospective Comparison with Digital Subtraction Angiography.
PubMed 文献 · Ultrasound Med Biol · 2022-01-04

该前瞻性研究以数字减影血管造影为参考,纳入541条正常或颅内狭窄的椎基底动脉,评估超声检测弥漫性颅内椎基底动脉狭窄的价值。超声与DSA对多节段狭窄和多动脉狭窄的评估一致性不佳(κ=0.442和0.438)。识别关键狭窄和长段狭窄的最佳低速标准为:颅外椎动脉EDV≤15 cm/s、RI≥0.68,且RIica≥0.10。

要点

  • 对多节段狭窄和多动脉狭窄,超声与DSA的一致性不佳(κ=0.442和0.438)。
  • 低速组(关键狭窄和长段狭窄)的最佳超声标准为颅外椎动脉EDV≤15 cm/s、RI≥0.68,且RIica≥0.10。
  • 高速组包括局灶性狭窄、多节段狭窄和多动脉狭窄,低速组包括关键狭窄和长段狭窄。

核心结论

  • 超声检测颅内椎基底动脉狭窄时,对多节段狭窄和多动脉狭窄与DSA的一致性不佳;关键狭窄和长段狭窄的最佳低速标准为颅外椎动脉EDV≤15 cm/s、RI≥0.68,且RIica≥0.10。

研究设计与样本

  • 前瞻性研究,纳入541条正常或颅内狭窄的椎基底动脉,以数字减影血管造影为参考标准,测量颅内椎基底动脉和颅外椎动脉的收缩期峰值流速、平均流速及舒张末期流速(EDV),并计算颅外椎动脉阻力指数(RI)及颅外椎动脉RI与颅外颈内动脉RI(RIica)的差值。

诊断标准与关键数值

  • 识别颅内椎基底动脉关键狭窄和长段狭窄的最佳低速标准为:颅外椎动脉EDV≤15 cm/s、RI≥0.68,且RIica≥0.10。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The aim of this study was to prospectively evaluate diffuse intracranial vertebrobasilar artery stenosis by ultrasonic examination with digital subtraction angiography as the reference. Five hundred forty-one vertebrobasilar arteries with a normal lumen or intracranial stenosis were enrolled. Peak systolic velocity, mean flow velocity and end-diastolic velocity (EDV) at the intracranial vertebrobasilar arteries and extracranial vertebral arteries (VAs) were measured. The resistance index (RI) at extracranial VAs and the difference between the RI of extracranial VAs and the RI of the extracranial internal carotid artery (RIica) were calculated. Compared with normal arteries, all stenotic arteries were divided into the high-velocity group (focal stenosis, multiple-segment stenosis and multiple-artery stenosis) and low-velocity group (critical stenosis and long stenosis). The consistency between ultrasonic examination and digital subtraction angiography for evaluation of vertebrobasilar arteries with multiple-segment stenosis and multiple-artery stenosis was not favorable when applying the widely used Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis criteria (κ = 0.442 and 0.438, respectively). The optimal low-velocity criteria for identifying intracranial vertebrobasilar arteries with critical stenosis and long stenosis were determined by receiver operating characteristic curve analysis and were as follows: EDV ≤15 cm/s and RI ≥0.68 at the extracranial VA and RIica ≥0.10.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Zhang, Wang, Chen, et al. Non-invasive Detection of Diffuse Intracranial Vertebrobasilar Artery Stenosis: A Prospective Comparison with Digital Subtraction Angiography. Ultrasound Med Biol. 2022. PMID: 34996653. doi:10.1016/j.ultrasmedbio.2021.11.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。