基于深度卷积神经网络的脑转移瘤自动检测:有无血管抑制的对比研究
本研究回顾性纳入2016年3月至2019年7月临床怀疑脑转移瘤并接受VISIBLE检查的患者,利用有无血管抑制的图像训练DeepMedic卷积神经网络模型,并与12名放射科医生的观察者试验比较诊断性能。模型敏感度为91.7%,高于观察者试验的88.7±3.7%;模型每例假阳性数为1.5,高于观察者试验的0.17±0.09,但低于大多数既往深度学习研究。
要点
- 基于VISIBLE有/无血管抑制图像训练的CNN模型检测脑转移瘤敏感度为91.7%,高于12名放射科医生观察者试验的88.7±3.7%。
- 模型每例假阳性数为1.5,高于观察者试验的0.17±0.09,但低于大多数既往深度学习研究。
- 模型假阳性见于血管、脉络丛及图像噪声或不明原因。
核心结论
- 与放射科医生相比,基于VISIBLE和CNN构建的脑转移瘤诊断模型敏感度更高;模型每例假阳性数高于放射科医生观察者试验,但低于大多数既往深度学习研究。
研究设计与样本
- 回顾性研究,纳入50例临床怀疑脑转移瘤并接受VISIBLE检查的患者(男30例、女20例,年龄29-86岁,平均63.3±12.8岁,共165个转移灶)用于训练模型;使用有无血管抑制的图像训练现有CNN(DeepMedic),以敏感度和每例假阳性数评估诊断性能,并与12名放射科医生的观察者试验比较。
诊断标准与关键数值
- 模型敏感度为91.7%,观察者试验敏感度为88.7±3.7%(均值±标准差);模型每例假阳性数为1.5,观察者试验每例假阳性数为0.17±0.09。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To develop an automated model to detect brain metastases using a convolutional neural network (CNN) and volume isotropic simultaneous interleaved bright-blood and black-blood examination (VISIBLE) and to compare its diagnostic performance with the observer test.
METHODS: This retrospective study included patients with clinical suspicion of brain metastases imaged with VISIBLE from March 2016 to July 2019 to create a model. Images with and without blood vessel suppression were used for training an existing CNN (DeepMedic). Diagnostic performance was evaluated using sensitivity and false-positive results per case (FPs/case). We compared the diagnostic performance of the CNN model with that of the twelve radiologists.
RESULTS: Fifty patients (30 males and 20 females; age range 29-86 years; mean 63.3 ± 12.8 years; a total of 165 metastases) who were clinically diagnosed with brain metastasis on follow-up were used for the training. The sensitivity of our model was 91.7%, which was higher than that of the observer test (mean ± standard deviation; 88.7 ± 3.7%). The number of FPs/case in our model was 1.5, which was greater than that by the observer test (0.17 ± 0.09).
CONCLUSIONS: Compared to radiologists, our model created by VISIBLE and CNN to diagnose brain metastases showed higher sensitivity. The number of FPs/case by our model was greater than that by the observer test of radiologists; however, it was less than that in most of the previous studies with deep learning.
KEY POINTS: • Our convolutional neural network based on bright-blood and black-blood examination to diagnose brain metastases showed a higher sensitivity than that by the observer test. • The number of false-positives/case by our model was greater than that by the previous observer test; however, it was less than those from most previous studies. • In our model, false-positives were found in the vessels, choroid plexus, and image noise or unknown causes.
引用
- Kikuchi, Togao, Kikuchi, et al. A deep convolutional neural network-based automatic detection of brain metastases with and without blood vessel suppression. Eur Radiol. 2022. PMID: 34993572. doi:10.1007/s00330-021-08427-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。