文献速递乳腺乳腺X线

基于乳腺X线影像组学特征预测导管原位癌的术后升级

Prediction of Upstaging in Ductal Carcinoma in Situ Based on Mammographic Radiomic Features.
PubMed 文献 · Radiology · 2022-01-04

该回顾性研究纳入700例经空心针活检诊断为导管原位癌(DCIS)的女性,利用数字放大乳腺X线影像组学特征构建模型预测术后升级为浸润癌。测试集最佳模型AUC为0.71(95%CI: 0.62, 0.79);固定高敏感度90%时特异度22%、阴性预测值92%、OR 2.4(95%CI: 1.8, 3.2);高特异度90%时敏感度37%、阳性预测值41%、OR 5.0(95%CI: 2.8, 9.0)。作者认为基于乳腺X线钙化影像组学特征的机器学习模型可能有助于预测DCIS升级。

要点

  • 乳腺X线影像组学模型预测DCIS术后升级的测试集AUC为0.71(95%CI: 0.62, 0.79)。
  • 高敏感度(90%)设置下模型特异度22%、阴性预测值92%、OR 2.4(95%CI: 1.8, 3.2)。
  • 高特异度(90%)设置下模型敏感度37%、阳性预测值41%、OR 5.0(95%CI: 2.8, 9.0)。

核心结论

  • 基于乳腺X线钙化影像组学特征的机器学习模型可能有助于预测导管原位癌术后升级为浸润癌,从而辅助临床决策与治疗计划。

研究设计与样本

  • 符合《健康保险携带与责任法案》的回顾性研究,单中心,2008年9月至2017年4月因钙化行乳腺空心针活检并诊断为DCIS的无症状女性,共700例,随机分为训练集400例和测试集300例。

关键影像表现/征象

  • 研究针对无肿块、无结构扭曲、无不对称致密或可触及病变的无症状女性钙化。
  • 共提取109个影像组学特征和4个临床特征。
  • 采用正则化逻辑回归建模。

诊断标准与关键数值

  • 测试集最佳模型(全部影像组学与临床特征)预测升级的AUC为0.71(95%CI: 0.62, 0.79)。
  • 固定高敏感度90%时,模型特异度22%、阴性预测值92%、OR 2.4(95%CI: 1.8, 3.2)。
  • 固定高特异度90%时,模型敏感度37%、阳性预测值41%、OR 5.0(95%CI: 2.8, 9.0)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Improving diagnosis of ductal carcinoma in situ (DCIS) before surgery is important in choosing optimal patient management strategies. However, patients may harbor occult invasive disease not detected until definitive surgery. Purpose To assess the performance and clinical utility of mammographic radiomic features in the prediction of occult invasive cancer among women diagnosed with DCIS on the basis of core biopsy findings. Materials and Methods In this Health Insurance Portability and Accountability Act-compliant retrospective study, digital magnification mammographic images were collected from women who underwent breast core-needle biopsy for calcifications that was performed at a single institution between September 2008 and April 2017 and yielded a diagnosis of DCIS. The database query was directed at asymptomatic women with calcifications without a mass, architectural distortion, asymmetric density, or palpable disease. Logistic regression with regularization was used. Differences across training and internal test set by upstaging rate, age, lesion size, and estrogen and progesterone receptor status were assessed by using the Kruskal-Wallis or χ2 test. Results The study consisted of 700 women with DCIS (age range, 40-89 years; mean age, 59 years ± 10 [standard deviation]), including 114 with lesions (16.3%) upstaged to invasive cancer at subsequent surgery. The sample was split randomly into 400 women for the training set and 300 for the testing set (mean ages: training set, 59 years ± 10; test set, 59 years ± 10; P = .85). A total of 109 radiomic and four clinical features were extracted. The best model on the test set by using all radiomic and clinical features helped predict upstaging with an area under the receiver operating characteristic curve of 0.71 (95% CI: 0.62, 0.79). For a fixed high sensitivity (90%), the model yielded a specificity of 22%, a negative predictive value of 92%, and an odds ratio of 2.4 (95% CI: 1.8, 3.2). High specificity (90%) corresponded to a sensitivity of 37%, positive predictive value of 41%, and odds ratio of 5.0 (95% CI: 2.8, 9.0). Conclusion Machine learning models that use radiomic features applied to mammographic calcifications may help predict upstaging of ductal carcinoma in situ, which can refine clinical decision making and treatment planning. © RSNA, 2022.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Hou, Grimm, Mazurowski, et al. Prediction of Upstaging in Ductal Carcinoma in Situ Based on Mammographic Radiomic Features. Radiology. 2022. PMID: 34981975. doi:10.1148/radiol.210407

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。