心脏CT影像组学研究质量评估:一项系统综述
该系统综述采用影像组学质量评分(RQS)和TRIPOD系统评估心脏CT影像组学原始研究的方法学质量。共纳入15篇文献,平均RQS为9.9±7.3(占理想分36分的27.4%),TRIPOD总体依从率为63%,仅2项(13.3%)进行了外部验证,1项(6.7%)进行了校准分析并说明潜在临床效用,无研究进行体模研究或成本效益分析。结论认为当前心脏CT影像组学研究质量不足,需提高证据等级并改进临床效用分析与模型性能校准。
要点
- 心脏CT影像组学研究平均RQS仅9.9±7.3(27.4%),方法学质量不足。
- 仅2项(13.3%)研究进行外部验证,1项(6.7%)报告校准分析及潜在临床效用。
- 无研究进行体模研究或成本效益分析,TRIPOD总体依从率63%。
核心结论
- 当前心脏CT影像组学研究质量不足,需要更高等级证据,临床效用分析与模型性能校准有待改进。
研究设计与样本
- 系统综述,检索PubMed和EMBASE,纳入15篇心脏CT影像组学原始研究,由两名心脏放射科医师依据RQS和TRIPOD指南评估方法学质量。
诊断标准与关键数值
- 15篇文献中6篇(40%)关于冠状动脉疾病,6篇(40%)关于心肌梗死。
- 平均RQS为9.9±7.3,占理想分36分的27.4%,基本依从率为44.6%。
- 14篇(93.3%)研究进行特征选择,9篇(60%)进行研究验证,仅2篇(13.3%)进行外部验证。
- 2篇(13.3%)为前瞻性研究,仅1篇(6.7%)进行校准分析并说明潜在临床效用。
- 无研究进行体模研究和成本效益分析,TRIPOD总体依从率为63%。
局限性
- 原文结论指出心脏CT影像组学研究质量不足,需要更高等级证据,临床效用分析与模型性能校准有待改进。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the quality of current radiomics research on cardiac CT using radiomics quality score (RQS) and Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) systems.
METHODS: Systematic searches of PubMed and EMBASE were performed to identify all potentially relevant original research articles about cardiac CT radiomics. Fifteen original research articles were selected. Two cardiac radiologists assessed the quality of the methodology adopted in those studies according to the RQS and TRIPOD guidelines. Basic adherence rates for the following six key domains were evaluated: image protocol and reproducibility, feature reduction and validation, biologic/clinical utility, performance index, high level of evidence, and open science.
RESULTS: Among the 15 included articles, six (40%) were about coronary artery disease and six (40%) were about myocardial infarction. The mean RQS was 9.9 ± 7.3 (27.4% of the ideal score of 36), and the basic adherence rate was 44.6%. Fourteen (93.3%) and nine (60%) studies performed feature selection and validation, but only two (13.3%) of them performed external validation. Two studies (13.3%) were prospective, and only one study (6.7%) conducted calibration analysis and stated the potential clinical utility. None of the studies conducted phantom study and cost-effective analysis. The overall adherence rate for TRIPOD was 63%.
CONCLUSION: The quality of radiomics studies in cardiac CT is currently insufficient. A higher level of evidence is required, and analysis of clinical utility and calibration of model performance need to be improved.
KEY POINTS: • The quality of science of radiomics studies in cardiac CT is currently insufficient. • No study conducted a phantom study or cost-effective analysis, with further limitations being demonstrated in a high level of evidence for radiomics studies. • Analysis of clinical utility and calibration of model performance need to be improved, and a higher level of evidence is required.
引用
- Lee, Han, Suh, et al. Quality assessment of radiomics research in cardiac CT: a systematic review. Eur Radiol. 2022. PMID: 34981135. doi:10.1007/s00330-021-08429-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。