文献速递心血管CT

舒张期与收缩期冠状动脉CT血管成像衍生的血流储备分数在识别病变特异性缺血中的比较

Diastolic versus systolic coronary computed tomography angiography derived fractional flow reserve for the identification of lesion-specific ischemia.
PubMed 文献 · Eur J Radiol · 2021-12-14

本研究以有创血流储备分数(FFR)为参考标准,比较冠状动脉CT血管成像(CTA)衍生的舒张期(CT-FFR-D)与收缩期(CT-FFR-S)血流储备分数在识别缺血病变中的诊断效能。共分析151例参与者181个病变,其中110例参与者129个病变成像成功。CT-FFR-D的诊断敏感度、特异度和准确率均高于CT-FFR-S,ROC曲线下面积在患者水平和血管水平均显著更高(0.938 vs. 0.771,0.935 vs. 0.772,均p<0.0001)。在严重血流动力学病变(FFR≤0.7)中,CT-FFR-S与FFR的绝对差值显著大于CT-FFR-D与FFR的绝对差值。

要点

  • 舒张期CT-FFR识别缺血病变的敏感度、特异度和准确率均高于收缩期CT-FFR。
  • 舒张期CT-FFR的ROC曲线下面积在患者水平和血管水平均显著高于收缩期CT-FFR。
  • 在FFR≤0.7的严重病变中,舒张期CT-FFR与FFR的绝对差值更小。

核心结论

  • 舒张期衍生的CT-FFR在检测冠状动脉缺血病变方面优于收缩期衍生的CT-FFR,对于FFR<0.7的病变,舒张期测量的CT-FFR更接近FFR。

研究设计与样本

  • 本研究为 enrolled 疑似冠心病并拟行有创冠状动脉造影(ICA)和FFR以及冠状动脉CTA和CT-FFR的参与者(Clinicaltrials.gov:NCT03692936),时间为2018年9月至2019年10月;对每位参与者的收缩期和舒张期冠状动脉CTA进行后处理分别计算CT-FFR-S和CT-FFR-D,以FFR为参考标准比较诊断效能。

诊断标准与关键数值

  • 患者水平:CT-FFR-D敏感度88.9%、特异度91.3%、准确率90.1%;CT-FFR-S敏感度66.7%、特异度87.7%、准确率76.7%。
  • 血管水平:CT-FFR-D敏感度89.5%、特异度91.5%、准确率90.6%;CT-FFR-S敏感度66.7%、特异度87.0%、准确率77.9%。
  • ROC曲线下面积:患者水平CT-FFR-D 0.938 vs. CT-FFR-S 0.771(p<0.0001);血管水平CT-FFR-D 0.935 vs. CT-FFR-S 0.772(p<0.0001)。
  • 严重血流动力学病变(FFR≤0.7):CT-FFR-S与FFR绝对差值0.1636(IQR 0.0662-0.2586)vs. CT-FFR-D与FFR绝对差值0.0953(IQR 0.0496-0.1702),p=0.035。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the measurement discrepancy of coronary computed tomography angiography (CTA)-derived fractional flow reserve (FFR) between diastolic (CT-FFR-D) and systolic (CT-FFR-S) phases using FFR as the reference standard.

METHODS: Participants, suspected of coronary artery disease and indicated for invasive coronary angiography (ICA) and FFR and coronary CTA and CT-FFR, were enrolled in this study (Clinicaltrials.gov:NCT03692936) from September 2018 to October 2019. For every participant, coronary CTA of both systolic and diastolic phases was postprocessed to calculate CT-FFR-S and CT-FFR-D, respectively. Diagnostic sensitivity, specificity, accuracy, and the area under the receiver operating characteristic (ROC) curve were compared.

RESULTS: A total of 181 lesions from 151 participants (mean age 54.5 ± 7.8 years, 113 males) were analyzed. Of these, 129 lesions from 110 participants were successfully measured both in diastolic and systolic phases. Sensitivity, specificity, and accuracy of CT-FFR-D and CT-FFR-S on per-patient level were 88.9%, 91.3%, 90.1% and 66.7%, 87.7%, 76.7%, on per-vessel level were 89.5%, 91.5%, 90.6% and 66.7%, 87.0%, 77.9%, respectively. The ROC curve of CT-FFR-D was significantly higher than that of CT-FFR-S on both per-patient and per-vessel levels (0.938 vs. 0.771, 0.935 vs. 0.772, both p < 0.0001). In severe hemodynamic lesions (FFR ≤ 0.7), the absolute difference between CT-FFR-S and FFR was significantly higher than that between CT-FFR-D and FFR [0.1636, inter-quartile range (IQR): 0.0662-0.2586 vs. 0.0953, IQR: 0.0496-0.1702, p = 0.035].

CONCLUSION: CT-FFR derived in diastole was superior to that derived in systole in detecting coronary ischemic lesions. For lesions with FFR < 0.7, CT-FFR measured in the diastolic phase was noted to be more closely approximated to FFR.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Gao, Zhao, Song, et al. Diastolic versus systolic coronary computed tomography angiography derived fractional flow reserve for the identification of lesion-specific ischemia. Eur J Radiol. 2021. PMID: 34974364. doi:10.1016/j.ejrad.2021.110098

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。