对比增强超声联合细针穿刺洗脱液甲状腺球蛋白水平提高甲状腺乳头状癌转移性淋巴结的诊断准确性
研究纳入167例患者190枚超声疑似转移的颈部淋巴结,评估对比增强超声(CEUS)联合细针穿刺洗脱液甲状腺球蛋白(FNA-Tg)诊断甲状腺乳头状癌淋巴结转移的效能。FNA-Tg以6.15 ng/ml为阈值(AUC 0.925)诊断效能优于FNA或CEUS单独应用;三者联合灵敏度达100%但特异度降至51.3%。
要点
- FNA-Tg以6.15 ng/ml为阈值诊断转移性淋巴结的AUC为0.925(95%CI 0.885-0.966)。
- FNA-Tg灵敏度90.2%、NPV 86.1%、准确率88.9%,均高于FNA或CEUS单独应用。
- FNA、FNA-Tg与CEUS三者联合灵敏度及NPV均达100%,但特异度降至51.3%。
核心结论
- FNA、FNA-Tg与CEUS三者联合是检测甲状腺乳头状癌患者转移性淋巴结有前景的影像工具。
研究设计与样本
- 研究纳入2018年11月至2020年9月超声疑似转移的167例患者共190枚淋巴结,所有对象均行FNA、CEUS和FNA-Tg检查,最终结局由组织病理学或细胞学检查或随访影像确认,采用Wilcoxon秩和检验或卡方检验分析。
诊断标准与关键数值
- FNA-Tg以6.15 ng/ml为阈值识别转移性淋巴结,AUC 0.925(95%CI 0.885-0.966)。
临床应用与阅片要点
- FNA-Tg单独应用灵敏度90.2%、NPV 86.1%、准确率88.9%,高于FNA单独应用(分别为48.2%、57.4%、69.5%)和CEUS单独应用(分别为82.1%、67.7%、70.5%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the diagnostic performance of contrast-enhanced ultrasound (CEUS) combined with thyroglobulin (Tg) levels in fine-needle aspirates (FNA) washout fluid (FNA-Tg) in diagnosing cervical lymph node (LN) metastasis in papillary thyroid cancer (PTC) patients.
METHODS: Data from 190 LNs in 167 patients suspected of metastasis from the US between November 2018 and September 2020 were included. All subjects underwent FNA, CEUS, and FNA-Tg examinations. The final outcomes were confirmed by histopathological or cytological examination or follow-up imaging. Data were analyzed using the Wilcoxon rank-sum or chi-squared test. The diagnostic efficacy of FNA, CEUS, and FNA-Tg in diagnosing LNs was compared.
RESULTS: A cutoff value of 6.15 ng/ml (AUC 0.925, 95% confidence interval (CI) 0.885-0.966) successfully identified metastatic LNs. FNA missed 58 LN metastases, of these, 94.8% (55/58) were correctly diagnosed using the combination of CEUS and FNA-Tg. FNA-Tg showed higher sensitivity (90.2%), NPV (86.1%) and accuracy (88.9%) than either FNA (48.2, 57.4 and 69.5%, respectively) or CEUS (82.1, 67.7 and 70.5%, respectively) alone. The combination of CEUS, FNA and FNA-Tg resulted in maximal sensitivity (100%) and NPV (100%) but reduced specificity (51.3%) and overall diagnostic accuracy (80.0%). After adding FNA-Tg to discordant samples between CEUS and FNA, 81.9% of LNs (77/94) were correctly diagnosed.
CONCLUSIONS: The combination of FNA, FNA-Tg and CEUS was found to be a promising imaging tool in detecting metastatic LNs in PTC patients.
引用
- Liu, Tang, Chen, et al. A Combination of Contrast-Enhanced Ultrasound and Thyroglobulin Level in Fine-Needle Aspirates Improves Diagnostic Accuracy for Metastatic Lymph Nodes of Papillary Thyroid Carcinoma. J Ultrasound Med. 2021. PMID: 34971466. doi:10.1002/jum.15926
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。