基于扩散峰度成像的直方图分析:鉴别多形性胶质母细胞瘤与单发脑转移瘤并比较两种感兴趣区放置方式的诊断效能
研究纳入67例经组织学确诊的多形性胶质母细胞瘤(35例)和单发脑转移瘤(32例)患者,在增强区和全肿瘤区两个感兴趣区计算FA、MD、MK的直方图参数,用ROC分析评估诊断效能。多形性胶质母细胞瘤与单发脑转移瘤可通过基于DKI的直方图分析鉴别,感兴趣区放在增强区可获得更好的鉴别效果。
要点
- 增强区FA25的AUC最高,为0.815。
- 全肿瘤区FAmedian的AUC最高,为0.805。
- 增强区FA25的准确度显著高于全肿瘤区FAmedian。
核心结论
- 基于扩散峰度成像的直方图分析可鉴别多形性胶质母细胞瘤与单发脑转移瘤,感兴趣区放在增强区可获得更好的鉴别效果。
研究设计与样本
- 研究纳入67例经组织学确诊的患者,其中多形性胶质母细胞瘤35例、单发脑转移瘤32例;在所有层面上勾画增强区和全肿瘤区两个感兴趣区,计算FA、MD、MK的11个直方图参数;采用Mann-Whitney U检验比较两组参数,McNemar检验比较不同直方图参数的准确度,ROC分析评估诊断效能。
关键影像表现/征象
- 增强区中,多形性胶质母细胞瘤的FA10、FA25、FA75、FA90、FAmean、FAmedian、FAmax、MDmax、MDskewness和MKskewness显著高于单发脑转移瘤。
- 增强区中,多形性胶质母细胞瘤的FAskewness显著低于单发脑转移瘤。
- 全肿瘤区中,多形性胶质母细胞瘤的FA10、FA25、FA75、FA90、FASD、FAmean、FAmedian、FAmax、MDmax、MDskewness和MKskewness显著高于单发脑转移瘤。
诊断标准与关键数值
- 增强区FA25的AUC最高,为0.815。
- 全肿瘤区FAmedian的AUC最高,为0.805。
- 增强区FA25的准确度显著高于全肿瘤区FAmedian的准确度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the value of histogram analysis, using diffusion kurtosis imaging (DKI), in differentiating glioblastoma multiforme (GBM) from single brain metastasis (SBM) and to compare the diagnostic efficiency of different region of interest (ROI) placements.
METHOD: Sixty-seven patients with histologically confirmed GBM (n = 35) and SBM (n = 32) were recruited. Two ROIs-the contrast-enhanced area and whole-tumor area-were delineated across all slices. Eleven histogram parameters of fractional anisotropy (FA), mean diffusivity (MD), and mean kurtosis (MK) from both ROIs were calculated. All histogram parameter values were compared between GBM and SBM, using the Mann-Whitney U test. The accuracies of different histogram parameters were compared using the McNemar test. Receiver operating characteristic (ROC) analyses were conducted to assess the diagnostic performance.
RESULTS: In the contrast-enhanced area, FA10, FA25, FA75, FA90, FAmean, FAmedian, FAmax, MDmax, MDskewness, and MKskewness were significantly higher for GBM than for SBM. FAskewness was significantly lower for GBM than for SBM. FA25 (0.815) had the highest area under the curve (AUC). In the whole-tumor area, FA10, FA25, FA75, FA90, FASD, FAmean, FAmedian, FAmax, MDmax, MDskewness, and MKskewness were significantly higher for GBM than for SBM. FAmedian (0.805) had the highest AUC. The accuracy of FA25 in the contrast-enhanced area was significantly higher than that of the FAmedian in the whole-tumor area.
CONCLUSIONS: GBM and SBM can be differentiated using the DKI-based histogram analysis. Placing the ROI on the contrast-enhanced area results in better discrimination.
引用
- Gao, Gao, Kit Kung, et al. Histogram analysis based on diffusion kurtosis imaging: Differentiating glioblastoma multiforme from single brain metastasis and comparing the diagnostic performance of two region of interest placements. Eur J Radiol. 2021. PMID: 34972059. doi:10.1016/j.ejrad.2021.110104
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。