应变弹性成像与剪切波弹性成像对乳腺癌患者新辅助化疗反应的诊断性能:系统评价与Meta分析
该系统评价与Meta分析共纳入15项研究、1147例乳腺癌患者,评估应变弹性成像与剪切波弹性成像预测新辅助化疗反应的诊断性能。应变弹性成像汇总AUC为0.89(95%CI 0.86-0.91),敏感度87%(95%CI 75-94%),特异度80%(95%CI 72-84%);剪切波弹性成像汇总AUC为0.82(95%CI 0.78-0.85),敏感度79%(95%CI 72-84%),特异度81%(95%CI 71-88%)。作者认为两种弹性成像均表现出良好的预测性能,可能是有用的无创评估方法。
要点
- 应变弹性成像预测新辅助化疗反应的汇总AUC为0.89,敏感度87%,特异度80%。
- 剪切波弹性成像预测新辅助化疗反应的汇总AUC为0.82,敏感度79%,特异度81%。
- 两种弹性成像均可能是有用的无创评估乳腺癌新辅助化疗反应的方法。
核心结论
- 基于当前证据,应变弹性成像与剪切波弹性成像在预测乳腺癌患者新辅助化疗反应方面均表现出良好的诊断性能,可能是有用的无创评估方法。
研究设计与样本
- 系统评价与Meta分析,检索PubMed、Web of Science和Cochrane Library数据库截至2021年10月,共纳入15项研究、1147例乳腺癌患者,使用Stata 14.0计算汇总AUC、敏感度和特异度。
诊断标准与关键数值
- 应变弹性成像诊断新辅助化疗反应的汇总AUC为0.89(95%CI 0.86-0.91),敏感度87%(95%CI 75-94%),特异度80%(95%CI 72-84%)。
- 剪切波弹性成像诊断新辅助化疗反应的汇总AUC为0.82(95%CI 0.78-0.85),敏感度79%(95%CI 72-84%),特异度81%(95%CI 71-88%)。
临床应用与阅片要点
- 作者认为应变弹性成像与剪切波弹性成像可能是有用的无创方法,用于评估乳腺癌患者新辅助化疗反应。
- Deek's漏斗图未观察到发表偏倚。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the diagnostic performance of strain and shear wave elastography for the response to neoadjuvant chemotherapy (NAC) in breast cancer patients.
METHODS: Relevant studies were searched in the databases of PubMed, Web of Science and Cochrane Library until October 2021. The diagnostic performance of ultrasonic elastography for the response to NAC were estimated by calculating the area under the curve (AUC) with sensitivity and specificity using Stata 14.0.
RESULTS: A total of 15 studies that comprise 1147 breast cancer patients were included in this meta-analysis. The pooled AUC of strain elastography in diagnosing responses were 0.89 (95% CI = 0.86-0.91) with 87% (95% CI = 75-94%) of sensitivity and 80% (95% CI = 72-84%) of specificity. The pooled AUC of shear wave elastography in diagnosing response were 0.82 (95% CI = 0.78-0.85) with 79% (95% CI = 72-84%) of sensitivity and 81% (95% CI = 71-88%). No publication bias was observed across the studies using Deek's funnel plot.
CONCLUSIONS: Based on current evidence, this meta-analysis confirmed that strain and shear wave elastography exhibited favorable performance for predicting responses to NAC. Strain and shear wave elastography may be a useful, noninvasive method for the assessment of response to NAC in breast cancer patients.
引用
- Jin, Liu, Zhang, et al. Diagnostic Performance of Strain and Shear Wave Elastography for the Response to Neoadjuvant Chemotherapy in Breast Cancer Patients: Systematic Review and Meta-Analysis. J Ultrasound Med. 2021. PMID: 34967455. doi:10.1002/jum.15930
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。