儿童乳糜泻患者颈动脉内中膜厚度与饮食依从性关系的评估:一项单中心预试验
本研究为单中心前瞻性预试验,纳入80例经内镜十二指肠活检确诊的6至18岁乳糜泻患者,按无麸质饮食依从性分为依从组45例和不依从组35例,超声测量颈动脉内中膜厚度。依从组平均cIMT为0.44±0.028 mm,不依从组为0.54±0.036 mm,组间差异有统计学意义(P<.001);ROC曲线下面积为0.992(95%CI:0.978-1,P<.001),以0.486 mm为截断值区分依从与不依从患者的敏感度为96%(95%CI:0.83-0.99),特异度为94%(95%CI:0.79-0.99)。作者认为cIMT可作为饮食依从性及心血管风险的长期指标。
要点
- 儿童乳糜泻不依从无麸质饮食者颈动脉内中膜厚度高于依从者。
- cIMT截断值0.486 mm区分饮食依从性的敏感度96%、特异度94%。
- cIMT或可作为乳糜泻患者长期饮食依从性及心血管风险的指标。
核心结论
- 本研究在儿童乳糜泻患者中证实了长期无麸质饮食依从性与颈动脉内中膜厚度之间的关系,cIMT除用于评估临床前动脉粥样硬化外,还可作为饮食依从性及心血管风险的长期指标。
研究设计与样本
- 单中心、前瞻性预试验,纳入2020年11月至2021年5月在本院儿科胃肠病门诊随访、经内镜十二指肠活检确诊的6至18岁乳糜泻患者80例,按无麸质饮食依从性分为依从组45例和不依从组35例,随访期间常规进行血清学和生化检查,两组均用超声测量cIMT。
诊断标准与关键数值
- 无麸质饮食依从组平均cIMT为0.44±0.028 mm,不依从组为0.54±0.036 mm,组间差异有统计学意义(P<.001);ROC曲线分析区分两组的曲线下面积为0.992(95%CI:0.978-1,P<.001);cIMT截断值0.486 mm区分无麸质饮食依从患者与不依从患者的敏感度为96%(95%CI:0.83-0.99),特异度为94%(95%CI:0.79-0.99)。
临床应用与阅片要点
- 作者认为,目前一些作者用于评估临床前动脉粥样硬化的cIMT,也可作为饮食依从性及心血管风险的长期指标。
局限性
- 原文标题标明为预试验(Pilot Study)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to show the relationship between gluten-free diet (GFD) compliance in Celiac Disease (CD) and early atherosclerotic findings in pediatric patients and to test the effectiveness of carotid-intima-media-thickness (cIMT) to possibly predict long-term compliance to the GFD.
METHODS: Patients from 6 to 18 years of age with a diagnosis of CD confirmed by endoscopic duodenal biopsy who were followed at our hospital's pediatric gastroenterology outpatient clinic between November 2020 and May 2021 were evaluated in this single-center, prospective study. The study patients were divided into two groups according to GFD compliance. Serologic and biochemical tests were conducted routinely during the follow-up period. cIMT was measured using ultrasound for both groups.
RESULTS: A total of 80 patients (GFD-non-compliant: n = 35, GFD-compliant: n = 45) were evaluated. No significant differences were observed between the groups in terms of demographic data and pathology results. The mean cIMT value was 0.44 ± 0.028 mm for the GFD-compliant group and 0.54 ± 0.036 mm for the GFD-non-compliant group, with a statistically significant between-group difference (P < .001). The receiver operating characteristic curve analysis showed an area under the curve of 0.992 (95% confidence interval [CI]: 0.978-1, P < .001) for discrimination of the groups. In addition, a cutoff value of 0.486 mm for cIMT showed 96% (95% CI: 0.83-0.99) sensitivity and 94% (95% CI: 0.79-0.99) specificity for distinguishing GFD-compliant patients from non-GFD-compliant patients.
CONCLUSION: In this study, the relationship between long-term GFD compliance and cIMT was demonstrated in CD. Currently used by some authors for the assessment of preclinical atherosclerosis, cIMT can also be used as a long-term indicator of dietary compliance as well as cardiovascular risk.
引用
- Oktay, Yavuz. Evaluation of the Relationship Between Carotid Intima Media Thickness and Dietary Compliance in Pediatric Celiac Patients: A Single-Center Pilot Study. J Ultrasound Med. 2021. PMID: 34962314. doi:10.1002/jum.15934
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。