振荡试验用于超声评估偏头痛伴视觉先兆患者胎儿型大脑后动脉变异的验证
研究以CTA为金标准验证经颅彩色多普勒超声振荡试验识别胎儿型大脑后动脉(FPCA)变异的诊断准确性,并在横断面研究中前瞻性纳入90例伴视觉先兆偏头痛、52例无先兆偏头痛患者及49例健康对照。超声识别部分型FPCA特异度93%、敏感度77%,完全型FPCA特异度99%、敏感度78%;各组FPCA频率无显著差异(p=0.79),提示FPCA变异似乎不参与视觉先兆形成。
要点
- 振荡试验识别完全型FPCA特异度99%、敏感度78%,部分型FPCA特异度93%、敏感度77%。
- 伴视觉先兆偏头痛组FPCA频率44.4%(40/90),无先兆组42.3%(22/52),对照组49%(24/49),组间无显著差异。
- logistic回归校正年龄和性别后,偏头痛诊断与FPCA存在无交互效应。
核心结论
- 超声振荡试验可作为无创方法识别部分型和完全型FPCA变异,特异度高、敏感度尚可;研究结果提示FPCA变异似乎不参与视觉性偏头痛先兆的形成。
研究设计与样本
- 第一部分以CT血管造影(CTA)为设定金标准评估振荡试验诊断准确性;第二部分为横断面研究,前瞻性招募伴视觉先兆偏头痛(MWVA)90例、无先兆偏头痛(MWOA)52例及健康对照49例,行经颅彩色多普勒超声(TCCS)评估FPCA变异。
诊断标准与关键数值
- 以CTA为设定金标准,超声振荡试验识别部分型FPCA的敏感度77%、特异度93%、阳性预测值63%、阴性预测值96%;识别完全型FPCA的敏感度78%、特异度99%、阳性预测值88%、阴性预测值98%。
临床应用与阅片要点
- 阅片时可参考振荡试验对完全型FPCA的高特异度(99%)与对部分型FPCA的较高特异度(93%),但敏感度分别为78%和77%,阴性结果不能排除FPCA变异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Anatomic variants of the posterior circle of Willis, including the fetal-type posterior cerebral artery (FPCA), may contribute to the formation of visual aura in migraine. We sought to validate an oscillation test to investigate FPCA frequency in migraine using transcranial color-coded duplex ultrasonography (TCCS). First, the diagnostic accuracy of the oscillation test used to identify FPCA variants by TCCS was assessed in stroke patients with available computed tomography angiography (CTA) as the set gold standard. Second, in a cross-sectional study, patients with migraine with visual aura (MWVA) and migraine without aura (MWOA), as well as healthy controls, were prospectively recruited for sonographic assessment of FPCA variants. We compared FPCA frequency between migraine patients and controls using χ2-testing and performed logistic regression analysis to investigate a potential association between MWVA and the presence of FPCA variants. Specificity, sensitivity and positive and negative predictive values for sonographic identification of FPCA with CTA as the set gold standard were 93%, 77%, 63% and 96% (partial FPCA) and 99%, 78%, 88% and 98% (complete FPCA), respectively. One hundred forty-two migraine patients (39 ± 12 y, 90 MWVA and 52 MWOA) and 49 healthy controls (31 ± 12 y) were recruited. The χ2 testing did not reveal significant differences in FPCA frequency as assessed by TCCS (unilateral or bilateral, partial and/or complete) between migraine patients and controls (MWVA: 40/90 or 44.4%, MWOA: 22/52 or 42.3%, controls: 24/49 or 49%, p = 0.79). Similarly, the frequencies of partial FPCA (p = 0.61) and complete FPCA (p = 0.27) did not vary significantly among groups. Logistic regression analysis revealed no interaction effect between migraine diagnosis and FPCA prevalence (any FPCA), when adjusted for age and sex. The sonographic oscillation test can be used as a non-invasive method to identify partial and complete FPCA variants with high specificity and reasonable sensitivity. Our findings suggest that FPCA variants do not contribute to the formation of visual migraine aura.
引用
- Danyel, Brachaczek, Röhl, et al. Validation of an Oscillation Test for the Sonographic Assessment of Fetal-Type Posterior Cerebral Artery Variants in Migraine Patients with Visual Aura. Ultrasound Med Biol. 2021. PMID: 34961638. doi:10.1016/j.ultrasmedbio.2021.11.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。