三维自动乳腺超声与手持乳腺超声对致密乳腺病灶检出及BI-RADS特征描述的对比:592例研究
前瞻性纳入592例致密乳腺患者,同日先行自动乳腺超声(ABUS)再行手持超声(HHUS),比较两者病灶检出数量与BI-RADS分类一致性。ABUS检出病灶数少于HHUS,但两种方法均检出全部11个恶性病灶,BI-RADS分类一致性良好。
要点
- ABUS检出囊肿1005个、肿块270个,HHUS检出囊肿1491个、肿块336个,ABUS检出病灶数较少。
- 两种方法均检出全部11个恶性病灶,ABUS对致密乳腺恶性病灶检出可靠。
- ABUS与HHUS对可疑病灶(BI-RADS 0/3/4/5)检出的一致性良好(kappa=0.66,p<0.001)。
核心结论
- ABUS与HHUS对BI-RADS分类的二分法赋值一致性良好;ABUS检出病灶数少于HHUS,但两种方法均检出全部恶性病灶,ABUS是致密乳腺恶性病灶检出的可靠方法。
研究设计与样本
- 前瞻性研究,2017年7月至2019年8月连续纳入592例患者,同日先行ABUS后行HHUS,由3名乳腺放射科医生参与,记录病灶数量、类型及BI-RADS分类。
诊断标准与关键数值
- ABUS与HHUS对每侧乳腺囊肿检出的一致性良好(kappa 0.61-0.62,p<0.001);对每侧乳腺实性肿块检出的一致性中等(k=0.57-0.60,p<0.001);对可疑病灶检出的一致性良好(kappa=0.66,p<0.001)。
临床应用与阅片要点
- ABUS与HHUS对致密乳腺BI-RADS分类一致性良好,且两种方法均检出全部恶性病灶;ABUS检出病灶总数少于HHUS。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVE: We aimed to compare the diagnostic performance of an automated breast ultrasound system (ABUS) with handheld ultrasound (HHUS) in the detection and characterization of lesions regarding BI-RADS classification in women with dense breasts.
MATERIALS AND METHODS: After ethical approval, from July 2017 to August 2019, 592 consecutive patients were enrolled in this prospective study. On the same day, patients underwent ABUS followed by HHUS. Three breast radiologists participated in this study. The number and type of lesions and BI-RADS categorization of both ABUS and HHUS examinations of each patient were recorded in an excel file. The level of agreement between the two ultrasound systems in terms of lesion number and BI-RADS category were analyzed statistically.
RESULTS: ABUS and HHUS detected 1005 and 1491 cystic and 270 and 336 mass lesions in 592 patients respectively. ABUS and HHUS detected 171 and 167 positive/suspicious cases (BIRADS 0/3/4/5). Forty suspicious lesions underwent core needle biopsy whereas 11 malignant lesions were detected by both methods. The remaining lesions were followed with a mean of 31 months. The mean size of solid lesions detected by HHUS and ABUS was 7.67 mm (range 2.1-41 mm) and 7.74 mm (range 2-42 mm) respectively. The agreement for detection of cystic lesions between two methods for each breast was good (kappa: 0.61-0.62 p < 0.001). The agreement of two methods for solid mass lesions for each breast was moderate (k = 0.57-0.60 p < 0.001). There was good agreement between the two methods for detecting suspicious lesions (kappa = 0.66 p < 0.001).
CONCLUSION: The level of agreement of ABUS and HHUS for dichotomic assignment of BIRADS categories was good. Although ABUS detected fewer lesions compared to HHUS, both methods detected all malignant lesions. ABUS is a reliable method for the detection of malignancy in dense breasts.
引用
- Güldogan, Yılmaz, Arslan, et al. Comparison of 3D-Automated Breast Ultrasound With Handheld Breast Ultrasound Regarding Detection and BI-RADS Characterization of Lesions in Dense Breasts: A Study of 592 Cases. Acad Radiol. 2021. PMID: 34955365. doi:10.1016/j.acra.2021.11.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。