欧洲患者接触屏蔽共识

European consensus on patient contact shielding.
指南 / 共识 · Phys Med · 2021-12-23

患者接触屏蔽长期用于降低电离辐射对特定器官的影响,但数字探测器和自动曝光控制等技术已降低剂量并改善图像一致性。欧洲多个专业机构基于GAPS专家组意见形成共识,旨在提供清晰易用的屏蔽使用指导,并承认欧洲各地法规与实践差异较大。

要点

  • 数字 receptors 和自动曝光控制等技术已降低投影成像和CT的剂量。
  • 共识由欧洲医学物理、放射技师、放射学、儿科放射学等机构共同制定。
  • 推荐意见旨在为患者屏蔽使用的变更管理提供参考。

核心结论

  • 共识基于GAPS专家组的推荐,旨在为欧洲患者接触屏蔽的使用提供清晰易用的指导。
  • 承认欧洲各地关于患者屏蔽的法规、习惯和实践差异很大,希望推荐能推动使患者和工作人员受益的变更管理。

研究设计与样本

  • 由欧洲医学物理组织联合会、欧洲放射技师协会联合会、欧洲放射学会、欧洲儿科放射学会、EuroSafe Imaging、欧洲辐射剂量学组和欧洲口腔颌面放射学会共同发布的共识文件。
  • 基于为形成该领域共识而成立的性腺与患者屏蔽(GAPS)专家组的专家推荐,采用多学科团队方法制定。

临床应用与阅片要点

  • 推荐意见为指南性质,旨在清晰易用,供放射科在日常工作中参考。
  • 原文未据此给出具体操作推荐。

局限性

  • 原文指出欧洲各地关于患者屏蔽的法规、习惯和实践差异很大。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Patient contact shielding has been in use for many years in radiology departments in order to reduce the effects and risks of ionising radiation on certain organs. New technologies in projection imaging and CT scanning such as digital receptors and automatic exposure control (AEC) systems have reduced doses and improved image consistency. These changes and a greater understanding of both the benefits and the risks from the use of shielding have led to a review of shielding use in radiology. A number of professional bodies have already issued guidance in this regard. This paper represents the current consensus view of the main bodies involved in radiation safety and imaging in Europe: European Federation of Organisations for Medical Physics, European Federation of Radiographer Societies, European Society of Radiology, European Society of Paediatric Radiology, EuroSafe Imaging, European Radiation Dosimetry Group (EURADOS), and European Academy of DentoMaxilloFacial Radiology (EADMFR). It is based on the expert recommendations of the Gonad and Patient Shielding (GAPS) Group formed with the purpose of developing consensus in this area. The recommendations are intended to be clear and easy to use. They are intended as guidance, and they are developed using a multidisciplinary team approach. It is recognised that regulations, custom and practice vary widely on the use of patient shielding in Europe and it is hoped that these recommendations will inform a change management program that will benefit patients and staff.

来源:Phys Med,查看原文。版权归原作者所有。

引用

  1. Hiles, Gilligan, Damilakis, et al. European consensus on patient contact shielding. Phys Med. 2021. PMID: 34955383. doi:10.1016/j.ejmp.2021.12.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。