文献速递心血管外周血管胸部MR

球囊肺动脉成形术对不可手术慢性血栓栓塞性肺动脉高压患者右心室机械功能障碍的影响:一项心脏磁共振研究

Effects of BPA on right ventricular mechanical dysfunction in patients with inoperable CTEPH - A cardiac magnetic resonance study.
PubMed 文献 · Eur J Radiol · 2021-12-17

本研究对30例不可手术的慢性血栓栓塞性肺动脉高压患者,在球囊肺动脉成形术(BPA)前及术后6个月行1.5T心脏磁共振和右心导管检查,采用特征追踪应变分析评估右心室机械功能。结果显示BPA后右心室射血分数升高、肺动脉平均压和肺血管阻力下降,右心室整体纵向、 circumferential和径向应变均改善,室间隔原生T1时间降低,且整体纵向应变与右心室功能、肺血流动力学及心肌重构相关良好。

要点

  • BPA术后6个月右心室射血分数从35.9%升至48.4%,肺动脉平均压从42.1 mmHg降至33.1 mmHg,肺血管阻力从551.8降至377.7 dyn·s/cm⁵(均p<0.0001)。
  • 右心室整体纵向应变从-19.9%增至-24.0%(p=0.0003),整体 circumferential 应变从-9.4%增至-11.0%(p=0.0022),整体径向应变从38.2%增至50.7%(p=0.001)。
  • 整体纵向应变与右心室射血分数相关性最好(BPA前r=-0.75,BPA后r=-0.54),与肺动脉平均压、肺血管阻力及室间隔面积校正T1时间亦相关。

核心结论

  • BPA可显著改善不可手术CTEPH患者的右心室机械功能障碍、肺血流动力学及心肌重构,右心室应变值与右心室功能、肺血流动力学及心肌重构相关性良好,应变分析可能为治疗结局、监测和预后提供新见解。

研究设计与样本

  • 前瞻性自身对照研究,纳入30例不可手术的CTEPH患者(平均年龄63.4±10.6岁,女性17例),在BPA前及术后6个月行1.5T心脏磁共振和右心导管检查,采用特征追踪应变分析测定右心室整体纵向、 circumferential和径向应变,并与右心室功能、原生T1时间及肺血流动力学比较。

关键影像表现/征象

  • BPA术后右心室射血分数从35.9%升高至48.4%(p<0.0001)。
  • BPA术后右心室整体纵向应变从-19.9%增至-24.0%(p=0.0003),整体 circumferential 应变从-9.4%增至-11.0%(p=0.0022),整体径向应变从38.2%增至50.7%(p=0.001)。
  • BPA术后室间隔面积校正原生T1时间从1019.4 ms降至988.7 ms(p<0.0001)。
  • BPA术后肺动脉平均压从42.1 mmHg降至33.1 mmHg,肺血管阻力从551.8降至377.7 dyn·s/cm⁵(均p<0.0001)。

诊断标准与关键数值

  • 右心室整体纵向应变与右心室射血分数相关性:BPA前r=-0.75,BPA后r=-0.54。
  • 右心室整体纵向应变与肺动脉平均压相关性:BPA前r=0.36,BPA后r=0.52。
  • 右心室整体纵向应变与肺血管阻力相关性:BPA前r=0.49,BPA后r=0.48。
  • 右心室整体纵向应变与室间隔面积校正T1时间相关性:BPA前r=0.44,BPA后r=0.19。

临床应用与阅片要点

  • 对不可手术CTEPH患者行BPA前后,可采用心脏磁共振特征追踪应变分析评估右心室机械功能改变,整体纵向应变与右心室射血分数、肺动脉平均压、肺血管阻力及心肌重构指标相关,可能为治疗结局、监测和预后提供新见解(作者结论)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to assess effects of balloon pulmonary angioplasty (BPA) on right ventricular (RV) mechanical dysfunction in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) via MRI.

METHOD: MRI at 1.5 Tesla and right heart catheterization were performed before and 6 months after BPA in 30 CTEPH patients (mean age 63.4 ± 10.6 years; 17 female). Feature-tracking strain analysis, including global longitudinal (GLS), circumferential (GCS), and radial (GRS) strain, was performed and compared with right ventricular function, myocardial remodelling (assessed by native T1 times), and pulmonary haemodynamics (mean pulmonary arterial pressure and pulmonary vascular resistance).

RESULTS: RVEF (35.9% to 48.4%) increased and mPAP (42.1 mmHg to 33.1 mmHg) and PVR (551.8 to 377.7 dyn∙s/cm5) decreased after BPA (all p < 0.0001). Moreover, RV strain increased (GLS -19.9 to -24.0%, p = 0.0003; GCS -9.4 to -11.0%, p = 0.0022; GRS 38.2 to 50.7%, p = 0.001) and septal native area-adjusted T1 time (AA-T1) decreased (1019.4 to 988.7 ms, p < 0.0001). GLS revealed the best correlations with RVEF (before BPA r = -0.75; after BPA r = -0.54), mPAP (r = 0.36; r = 0.52), PVR (r = 0.49; r = 0.48), and AA-T1 (r = 0.44; 0.19).

CONCLUSION: RV mechanical dysfunction, pulmonary haemodynamics, and myocardial remodelling are markedly improved by BPA. Moreover, RV strain values showed good correlations with RV function, pulmonary haemodynamics, and myocardial remodelling. Therefore, strain analysis might provide new insights regarding therapy outcome, monitoring, and prognosis.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Roller, Schüssler, Hasse, et al. Effects of BPA on right ventricular mechanical dysfunction in patients with inoperable CTEPH - A cardiac magnetic resonance study. Eur J Radiol. 2021. PMID: 34952330. doi:10.1016/j.ejrad.2021.110111

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。