非增强FLAIR序列可视化球囊和椭圆囊
本研究通过模拟和22名健康受试者3.0-T MRI扫描,优化非增强3D-FLAIR参数以区分外淋巴间隙和内淋巴间隙。采用T2准备400 ms和反转时间2100 ms时,球囊和椭圆囊显示最佳(87%病例)。在一位梅尼埃病患者中,优化非增强3D-FLAIR的显示效果与常规增强3D-FLAIR相似。
要点
- 非增强3D-FLAIR使用T2Prep 400 ms和TI 2100 ms可区分外淋巴间隙与内淋巴间隙。
- 该参数下球囊和椭圆囊在87%病例中显示最佳,最高分辨率0.6×0.6×0.6 mm³。
- 一例梅尼埃病患者中,优化非增强3D-FLAIR显示球囊和椭圆囊与增强3D-FLAIR相似。
核心结论
- 联合特定T2Prep和TI的非增强3D-FLAIR可分离外淋巴间隙和内淋巴间隙,甚至显示球囊和椭圆囊,为未来诊断梅尼埃病铺路。
研究设计与样本
- 研究先进行信号模拟,后对22名健康受试者在3.0-T MRI上扫描,使用非增强3D-FLAIR,变化T2Prep(OFF、200、400、600 ms)、反转时间(224至5000 ms)和分辨率(1.0×1.0×1.5、0.6×0.6×0.8、0.6×0.6×0.6 mm³);另在一例梅尼埃病患者中测试最优设置并与钆增强3D-FLAIR比较。
关键影像表现/征象
- 使用T2Prep时外淋巴间隙和内淋巴间隙可区分,不使用T2Prep时不能区分。
- T2Prep 400 ms时相对对比度大于200 ms和600 ms,分别为0.72 ± 0.22 vs. 0.44 ± 0.11(p = 0.019)和0.72 ± 0.22 vs. 0.46 ± 0.28(p = 0.034)。
- 球囊和椭圆囊在T2Prep=400 ms、TI=2100 ms、最高分辨率(0.6×0.6×0.6 mm³)时87%病例显示最佳。
- 一例梅尼埃病患者中,优化非增强3D-FLAIR显示球囊和椭圆囊与常规增强3D-FLAIR相似。
诊断标准与关键数值
- 外淋巴间隙和内淋巴间隙的相对对比度在T2Prep 400 ms时为0.72 ± 0.22,200 ms时为0.44 ± 0.11(p = 0.019),600 ms时为0.46 ± 0.28(p = 0.034)。
- 球囊和椭圆囊最佳显示条件为T2Prep=400 ms、TI=2100 ms、分辨率0.6×0.6×0.6 mm³,87%病例显示最佳。
临床应用与阅片要点
- 非增强3D-FLAIR使用T2Prep 400 ms和TI 2100 ms可区分外淋巴间隙和内淋巴间隙并显示球囊和椭圆囊,可能用于未来梅尼埃病诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: 3D-fluid attenuation inversion recovery (FLAIR) collected 4 h after intravenous gadolinium injection can delineate the perilymphatic space (PLS) from the endolymphatic space (ELS) to capture endolymphatic hydrops, the pathological counterpart of Ménière's disease. We aimed to optimize visualization of such inner ear internal anatomy using 3D-FLAIR without injection.
METHODS: 3D-FLAIR signal from different fluid compartments such as PLS and ELS was first simulated. Then, twenty-two healthy subjects were scanned at 3.0-T MRI with non-injected 3D-FLAIR using variable T2 preparations (T2Preps) (OFF, 200, 400, and 600 ms) and variable inversion times (TIs) (from 224 to 5000 ms) and different resolutions (1.0 × 1.0 × 1.5, 0.6 × 0.6 × 0.8, and 0.6 × 0.6 × 0.6 mm3). The relative contrast between PLS and ELS and the visibility of the saccule and utricle were assessed. Additionally, non-injected 3D-FLAIR with the optimal setting was tested in a Ménière patient and compared with gadolinium-injected 3D-FLAIR.
RESULTS: The PLS and ELS were differentiated when T2Prep was used but not without. The relative contrast was larger with T2Prep at 400 ms than at 200 or 600 ms (0.72 ± 0.22 vs. 0.44 ± 0.11, p = 0.019; and 0.72 ± 0.22 vs. 0.46 ± 0.28, p = 0.034, respectively). The saccule and utricle were best delineated in 87. % cases with T2Prep = 400 and TI = 2100 ms at the highest resolution. Visualization of the saccule and utricle in the optimized non-injected 3D-FLAIR was similar to conventional injected 3D-FLAIR in a patient.
CONCLUSIONS: Combining a specific T2Prep and TI in non-injected 3D-FLAIR could separate PLS and ELS and even the saccule and utricle, paving the way toward future application to diagnose Ménière's disease.
KEY POINTS: • MRI can capture the internal anatomy of inner ear without injection of contrast media. • Specific parameters consisting of a T2 preparation of 400 ms and an inversion time of 2100 ms must be used to visualize the saccule and utricle on non-injected 3D-FLAIR.