文献速递头颈甲状腺与浅表技术与安全US

原发性甲状腺鳞状细胞癌的超声特征

Ultrasonic Characterization of Primary Squamous Cell Carcinoma of the Thyroid.
PubMed 文献 · J Ultrasound Med · 2021-12-20

研究纳入20年间8例患者共9个原发性甲状腺鳞状细胞癌(PSCCT),回顾其超声特征并评估2015 ATA指南与2017 ACR TI-RADS的价值。PSCCT多表现为较大、低回声或极低回声实性结节,伴结节内血流及甲状腺外侵犯;两种指南体系均能将其识别为可疑恶性并推荐细针穿刺。

要点

  • PSCCT平均大小3.87±1.41 cm,均为低回声或极低回声实性结节伴结节内血流。
  • 44.4%的PSCCT可见甲状腺外侵犯,33.3%可见纵横比大于1及颈部淋巴结肿大。
  • 2015 ATA将全部PSCCT归为高度可疑模式并推荐FNA;2017 ACR TI-RADS将66.7%归为5类、其余为4类,88.9%推荐FNA。

核心结论

  • PSCCT具有一定的超声特征,包括体积相对较大、低回声或极低回声实性结节、结节内血流及甲状腺外侵犯;2015 ATA指南与2017 ACR TI-RADS均能将其识别为可疑恶性。

研究设计与样本

  • 回顾性分析20年研究期间8例患者共9个PSCCT的超声特征,评估结节回声、组成、形态、边缘、钙化、大小、血流及颈部淋巴结病变,并分别按2017 ACR TI-RADS与2015 ATA指南分类。

关键影像表现/征象

  • PSCCT平均大小3.87±1.41 cm,全部为低回声或极低回声实性结节伴结节内血流,平均阻力指数(RI)0.84±0.18。

诊断标准与关键数值

  • 2015 ATA将全部9个PSCCT归为高度可疑模式并推荐FNA;2017 ACR TI-RADS将6个(66.7%)归为5类、其余归为4类,8个(88.9%)推荐FNA。

临床应用与阅片要点

  • 阅片时需注意PSCCT可表现为较大、低回声或极低回声实性结节伴结节内血流,44.4%可见甲状腺外侵犯,33.3%可见纵横比大于1及颈部淋巴结肿大,11.1%可见微钙化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To identify the ultrasonographic characteristics of primary squamous cell carcinoma of the thyroid (PSCCT), and to assess the value of the 2015 American Thyroid Association (ATA) guideline and 2017 American College of Radiology (ACR) Thyroid Imaging, Reporting and Data System (TI-RADS) in the evaluation of this disease.

METHODS: Eight patients with 9 PSCCTs over a 20-year study period were enrolled. Ultrasonic characteristics including nodule echogenicity, composition, shape, margin, calcification, size, vascularity, and cervical lymphadenopathy were reviewed. All nodules were then evaluated by 2017 ACR TI-RADS and 2015 ATA guidelines.

RESULTS: The average size of PSCCTs was 3.87 ± 1.41 cm. All PSCCTs were hypoechoic or very hypoechoic, solid nodules with intranodular vascularity. The average resistive index (RI) was 0.84 ± 0.18. Near half of PSCCTs (44.4%) demonstrated extrathyroidal extension. Taller-than-wide signs and cervical lymphadenopathy were observed in 33.3% of PSCCTs, and microcalcification was observed in 11.1% of them. All PSCCTs were classified as high suspicion patterns by 2015 ATA and recommended for fine-needle aspiration (FNA). Six PSCCTs (66.7%) were classified as grade 5 by 2017 ACR TI-RADS, while the remaining were grade 4. 88.9% of PSCCTs were recommended for FNA based on 2017 ACR TI-RADS.

CONCLUSION: PSCCT has certain ultrasonic features, including relatively large, hypoechoic, or very hypoechoic solid nodules with intranodular vascularity and extrathyroidal extension. Both 2015 ATA and 2017 ACR TI-RADS could identify PSCCT as suspicious for malignancy.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhang, Chen, Zhang, et al. Ultrasonic Characterization of Primary Squamous Cell Carcinoma of the Thyroid. J Ultrasound Med. 2021. PMID: 34927280. doi:10.1002/jum.15918

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。