文献速递头颈技术与安全USCT

对比增强超声与四维计算机断层扫描在甲状旁腺腺瘤术前检测与定位中的效用:与手术结果的比较

Utility of Contrast-Enhanced Ultrasound and 4-Dimensional Computed Tomography for Preoperative Detection and Localization of Parathyroid Adenomas Compared With Surgical Results.
PubMed 文献 · J Ultrasound Med · 2021-12-16

本研究纳入27例疑似甲状旁腺病变患者行4DCT和CEUS检查,其中22例随后接受手术切除。对于单腺体病变,CEUS定位至正确象限和侧别的准确率分别为81.0%和90.1%,4DCT分别为81.0%和90.5%,两者敏感度和特异度相当;4DCT在多腺体病变中可准确诊断,而CEUS则不能。作者认为CEUS定位准确性与4DCT相当,可考虑用于术前初步诊断,尤其年轻患者。

要点

  • 单腺体病变中,CEUS定位正确象限和侧别的准确率分别为81.0%和90.1%。
  • 4DCT定位正确象限和侧别的准确率分别为81.0%和90.5%,敏感度和特异度与CEUS相当。
  • 4DCT可准确诊断多腺体病变,而CEUS则不能。

核心结论

  • CEUS是一种无创、实时成像技术,对甲状旁腺腺瘤的术前检测、特征描述和定位具有较高的诊断信心和准确性,与4DCT相当;作者认为该技术可考虑用于术前初步诊断,尤其年轻患者。

研究设计与样本

  • 共27例疑似甲状旁腺病变患者接受4DCT和CEUS成像评估,其中22例随后接受甲状旁腺病变手术切除;4DCT和CEUS由两名在各自模态经验丰富的放射科医生共识解读;以手术报告为参考标准评估病变侧别、z轴(头尾轴)和象限。

诊断标准与关键数值

  • 单腺体病变中,CEUS定位至正确象限的准确率为81.0%,定位至正确侧别的准确率为90.1%。
  • 单腺体病变中,4DCT定位至正确象限的准确率为81.0%,定位至正确侧别的准确率为90.5%。
  • 4DCT定位的敏感度和特异度与CEUS相当。
  • 4DCT可准确诊断多腺体病变,而CEUS则不能。

临床应用与阅片要点

  • 作者认为CEUS可考虑用于甲状旁腺腺瘤的术前初步诊断,尤其年轻患者。
  • 4DCT在多腺体病变中可准确诊断,CEUS则不能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the accuracy, sensitivity, and specificity of contrast-enhanced ultrasound (CEUS) for detection of parathyroid adenomas and compare it to those of 4-dimensional computed tomography (4DCT), which has been established as a reliable, effective tool for preoperative localization of parathyroid adenomas.

METHODS: About 27 patients with suspected parathyroid pathology underwent imaging evaluations with 4DCT and CEUS and 22 patients subsequently underwent surgical resection of parathyroid lesions. 4DCT and CEUS were performed and interpreted by consensus of two expert radiologists with extensive experience in each modality. Assessment for the side, z-axis (craniocaudal axis), and quadrant of the pathologically proven lesion was performed based on the surgical report.

RESULTS: For single-gland disease, the accuracy for CEUS localization to the correct quadrant and side were 81.0 and 90.1% respectively. For single-gland disease, the accuracy for 4DCT localization to the correct quadrant and side were 81.0 and 90.5% respectively. 4DCT localization sensitivity and specificity were comparable to those for CEUS. 4DCT allowed for accurate diagnosis in multigland disease in contradistinction to CEUS.

CONCLUSIONS: CEUS is a noninvasive, real-time imaging technique that has relatively high diagnostic confidence and accuracy of localization which are comparable to the accuracy of 4DCT for preoperative parathyroid adenoma detection, characterization, and localization. This technique should be considered for primary preoperative diagnosis, especially in younger patients.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Lerner, Grant, Acharya, et al. Utility of Contrast-Enhanced Ultrasound and 4-Dimensional Computed Tomography for Preoperative Detection and Localization of Parathyroid Adenomas Compared With Surgical Results. J Ultrasound Med. 2021. PMID: 34918364. doi:10.1002/jum.15916

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。