二维剪切波弹性成像测量肝硬度评估肝细胞癌患者术前肝功能的可行性
前瞻性纳入143例2018年8月至2019年12月接受手术切除的肝细胞癌患者,术前用二维剪切波弹性成像测肝硬度,并与血清生化指标、Child-Pugh评分、ALBI评分、MELD评分及吲哚菁绿清除试验结果进行相关性分析。肝硬度与ICG R15呈中度相关(Pearson r=0.62),鉴别ICG R15正常的最佳截断值为10.6 kPa,AUC 0.874、敏感度0.900、特异度0.724。作者认为肝硬度可能成为肝细胞癌术前肝功能评估的潜在工具。
要点
- 肝硬度与ICG R15中度相关(Pearson r=0.62,p<0.001)。
- 鉴别ICG R15正常的最佳截断值为10.6 kPa,AUC 0.874、敏感度0.900、特异度0.724。
- 肝硬度与Child-Pugh评分、ALBI评分仅呈弱相关(均p<0.001)。
核心结论
- 二维剪切波弹性成像测得的肝硬度可能成为肝细胞癌患者术前肝功能评估的潜在工具。
研究设计与样本
- 前瞻性纳入2018年8月至2019年12月接受手术切除的肝细胞癌患者143例。
- 术前进行肝硬度测量、血清生化肝功能检查及吲哚菁绿清除试验,并计算Child-Pugh评分、ALBI评分和MELD评分。
- ICG R15与ICG消除速率常数(ICG K)由设备自动测定,纤维化分期依据病理结果确定。
诊断标准与关键数值
- 肝硬度与肝功能血清生化指标呈弱至中度相关(均p<0.01)。
- 肝硬度与Child-Pugh评分、ALBI评分均呈弱相关(均p<0.001)。
- 肝硬度与ICG R15呈中度相关(Pearson r=0.62,p<0.001),与ICG K值呈中度相关(Pearson r=-0.49,p<0.001)。
- 鉴别ICG R15正常的最佳肝硬度截断值为10.6 kPa,AUC 0.874、敏感度0.900、特异度0.724。
临床应用与阅片要点
- 作者认为二维剪切波弹性成像测得的肝硬度可能成为肝细胞癌患者术前肝功能评估的潜在工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the feasibility of liver stiffness (LS) measured using two-dimensional shear wave elastography (2D SWE) in assessing preoperative liver function for patients with hepatocellular carcinoma (HCC).
MATERIALS AND METHODS: A total of 143 patients who underwent surgical resection for HCC between August 2018 and December 2019 were enrolled prospectively. LS measurement, liver function tests including serum biochemical indicators, and indocyanine green (ICG) clearance test were performed preoperatively. Child-Pugh (CP) score, Albumin-bilirubin (ALBI) score and Model for End-Stage Liver Disease score were calculated. ICG retention rate at 15 min (ICG R15) and ICG elimination rate constant (ICG K) were determined automatically. Fibrosis stage was determined based on pathological findings. The association between LS and serum biochemical indicators, liver function scores, and the ICG results were analyzed.
RESULTS: Weak to moderate correlations were identified between LS and biochemical indicators of liver function (all p < 0.01). Weak correlation was identified between LS and CP score, and between LS and ALBI score (all p < 0.001). Moderate correlation was identified between LS and ICG R15 (Pearson r = 0.62, p < 0.001), and between LS and ICG K value (Pearson r = - 0.49, p < 0.001). The best cutoff of LS to discriminate a normal ICG R15 was 10.6 kPa, with area under the curve (AUC), sensitivity, specificity of 0.874, 0.900 and 0.724, respectively.
CONCLUSIONS: LS determined using 2D SWE could be a potential tool for the preoperative evaluation of liver function in patients with HCC.
引用
- Long, Xu, Zhong, et al. Feasibility of liver stiffness measured using two-dimensional shear wave elastography in assessing preoperative liver function for patients with hepatocellular carcinoma. Abdom Radiol (NY). 2021. PMID: 34914008. doi:10.1007/s00261-021-03374-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。