文献速递心血管CTDSA

基于人工智能的应用在单能冠状动脉CT血管造影中检测斑块所致狭窄的性能:以有创冠状动脉造影验证

Performance of an Artificial Intelligence-based Application for the Detection of Plaque-based Stenosis on Monoenergetic Coronary CT Angiography: Validation by Invasive Coronary Angiography.
PubMed 文献 · Acad Radiol · 2021-12-09

回顾性纳入71例(52男19女,63.3±10.7岁)同时接受冠状动脉CTA和有创冠状动脉造影的患者,用AI在常规120 kVp图像和40–140 keV虚拟单能图像上自动检测斑块并计算狭窄程度,与有创冠状动脉造影比较。血管和节段分析显示常规CTA与50–90 keV虚拟单能图像诊断性能相当;斑块分析中50–100 keV虚拟单能图像平均诊断准确率与常规CTA无显著差异;高于100 keV时诊断准确率显著下降。

要点

  • AI在50–90 keV虚拟单能图像上检测冠状动脉显著狭窄的性能与常规120 kVp图像相当。
  • 高于100 keV的虚拟单能图像诊断准确率显著下降,不宜用于AI狭窄评估。
  • 斑块分析中50–100 keV虚拟单能图像平均诊断准确率与常规CTA无显著差异。

核心结论

  • AI应用于50–90 keV虚拟单能重建检测冠状动脉显著狭窄的性能与常规120 kVp重建相当;高于100 keV时诊断准确率显著下降。

研究设计与样本

  • 回顾性研究纳入71例连续患者(52男19女,63.3±10.7岁),均行冠状动脉CTA和有创冠状动脉造影;重建常规120 kVp图像及40–140 keV(每10 keV递增)共8种虚拟单能图像;AI系统自动检测斑块并计算狭窄程度,与有创冠状动脉造影比较,在节段、血管和患者水平评估。

诊断标准与关键数值

  • 血管水平常规CTA敏感度74.3%(95%CI 64.9%-82.0%)、特异度85.6%(95%CI 77.0%-91.4%)、阳性预测值84.3%(95%CI 75.2%-90.7%)、阴性预测值76.1%(95%CI 67.1%-83.3%)、诊断准确率79.8%(95%CI 73.7%-84.9%)。
  • 50–90 keV虚拟单能图像血管水平平均敏感度71.6%、特异度90.7%、阳性预测值87.5%、阴性预测值64.1%、诊断准确率81.6%。
  • 斑块分析中50–100 keV虚拟单能图像平均诊断准确率与常规CTA比较:钙化斑块91.4% vs 93.8%(p>0.05)、非钙化斑块92.6% vs 85.2%(p>0.05)、混合斑块80.2% vs 81.2%(p>0.05)。
  • 混合斑块所致狭窄检测中虚拟单能图像特异度略高:53.4% vs 40.0%(p>0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To explore the value of an artificial intelligence (AI)-based application for identifying plaque-specific stenosis and obstructive coronary artery disease from monoenergetic spectral reconstructions on coronary computed tomography angiography (CTA).

MATERIALS AND METHODS: This retrospective study enrolled 71 consecutive patients (52 men, 19 women; 63.3 ± 10.7 years) who underwent coronary CTA and invasive coronary angiography for diagnosing coronary artery disease. The conventional 120 kVp images and eight different virtual monoenergetic images (VMIs) (from 40 keV to 140 keV at increment of 10 keV) were reconstructed. An AI system automatically detected plaques from the conventional 120 kVp images and VMIs and calculated the degree of stenosis, which was further compared to invasive coronary angiography. The assessment was performed at a segment, vessel, and patient level.

RESULTS: Vessel and segment-based analyses showed comparable diagnostic performance between conventional CTA images and VMIs from 50 keV to 90 keV. For vessel-based analysis, the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of conventional CTA were 74.3% (95% CI: 64.9%-82.0%), 85.6% (95% CI: 77.0%-91.4%), 84.3% (95% CI: 75.2%-90.7%), 76.1% (95% CI: 67.1%-83.3%) and 79.8% (95% CI: 73.7%-84.9%), respectively; the average sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy values of the VMIs ranging from 50 keV to 90 keV were 71.6%, 90.7%, 87.5%, 64.1% and 81.6%, respectively. For plaque-based assessment, diagnostic performance of the average VMIs ranging from 50 keV to 100 keV showed no significant statistical difference in diagnostic accuracy compared to those of conventional CTA images in detecting calcified (91.4% vs. 93.8%, p > 0.05), noncalcified (92.6% vs. 85.2%, p > 0.05) or mixed (80.2% vs. 81.2%, p > 0.05) stenosis, although the specificity was slightly higher (53.4% vs. 40.0%, p > 0.05) in detecting stenosis caused by mixed plaques. For VMIs above 100 keV, the diagnostic accuracy dropped significantly.

CONCLUSION: Our study showed that the performance of an AI-based application employed to detect significant coronary stenosis in virtual monoenergetic reconstructions ranging from 50 keV to 90 keV was comparable to conventional 120 kVp reconstructions.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Yi, Xu, Guo, et al. Performance of an Artificial Intelligence-based Application for the Detection of Plaque-based Stenosis on Monoenergetic Coronary CT Angiography: Validation by Invasive Coronary Angiography. Acad Radiol. 2021. PMID: 34895831. doi:10.1016/j.acra.2021.10.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。