前瞻性机器学习CT定量评估接受抗纤维化治疗的特发性肺纤维化患者:低剂量与超低剂量CT的应用

Prospective machine learning CT quantitative evaluation of idiopathic pulmonary fibrosis in patients undergoing anti-fibrotic treatment using low- and ultra-low-dose CT.
PubMed 文献 · Clin Radiol · 2021-12-07

本研究对38例特发性肺纤维化患者行肺功能检查及标准、低剂量和超低剂量CT,用CALIPER机器学习工具定量血管相关结构、正常、网格影、蜂窝影和磨玻璃影,其中20例完成12个月随访。结果显示CALIPER间质性肺病范围与%FVC、%FEV1显著相关,低剂量与标准剂量CT一致性近乎完美,超低剂量为中等一致。作者认为CALIPER参数与肺功能相关性良好且不受剂量变化影响,可能作为肺功能的客观辅助手段。

要点

  • CALIPER间质性肺病范围与%FVC相关(ρrm -0.343,95%CI -0.547至-0.108,p=0.004)。
  • 血管相关结构与%FVC相关更强(ρrm -0.491,95%CI -0.685至-0.251,p=0.000)。
  • 低剂量与标准剂量CT的间质性肺病范围一致性CCC 0.995(95%CI 0.988-0.999)。

核心结论

  • CALIPER参数与肺功能检查在评估接受抗纤维化治疗的特发性肺纤维化患者时相关性良好,且不受剂量变化影响。
  • CALIPER可能作为肺功能的稳健、客观辅助手段,用于评估抗纤维化治疗相关变化。

研究设计与样本

  • 前瞻性研究,纳入38例特发性肺纤维化患者,其中20例完成12个月随访。
  • 患者接受肺功能检查及标准剂量、低剂量和超低剂量CT检查。
  • CALIPER将每个CT体素分类为血管相关结构、正常、网格影、蜂窝影或磨玻璃影,间质性肺病范围取磨玻璃影、网格影与蜂窝影之和。
  • 采用重复测量相关系数(ρrm)及95%CI评估CALIPER特征与肺功能的相关性,采用Lin一致性相关系数(CCC)评估不同剂量CT间CALIPER参数的一致性。

关键影像表现/征象

  • CALIPER间质性肺病范围与%FVC显著相关(p=0.004,ρrm -0.343,95%CI -0.547至-0.108)。
  • CALIPER间质性肺病范围与%FEV1显著相关(p=0.008,ρrm -0.321,95%CI -0.518至-0.07)。
  • 血管相关结构与%FVC显著相关(p=0.000,ρrm -0.491,95%CI -0.685至-0.251)。
  • 血管相关结构与%FEV1显著相关(p=0.000,ρrm -0.478,95%CI -0.653至-0.231)。

诊断标准与关键数值

  • 间质性肺病范围定义为磨玻璃影、网格影与蜂窝影数值之和。
  • 低剂量与标准剂量CT间质性肺病范围一致性CCC 0.995(95%CI 0.988-0.999),超低剂量与标准剂量CCC 0.9(95%CI 0.795-0.983)。
  • 低剂量与标准剂量CT血管相关结构一致性CCC 0.989(95%CI 0.963-0.997),超低剂量与标准剂量CCC 0.915(95%CI 0.806-0.956)。

临床应用与阅片要点

  • CALIPER参数与肺功能检查相关性良好,且不受剂量变化影响,可能作为评估抗纤维化治疗相关变化的客观辅助手段。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare the machine learning computed tomography (CT) quantification tool, Computer-Aided Lung Informatics for Pathology Evaluation and Ratings (CALIPER) to pulmonary function testing (PFT) in assessing idiopathic pulmonary fibrosis (IPF) for patients undergoing treatment and determine the effects of limited (LD) and ultra-low dose (ULD) CT on CALIPER performance.

MATERIALS AND METHODS: Thirty-eight IPF patients underwent PFT and standard, LD, and ULD CT. CALIPER classified each CT voxel into either vessel-related structures (VRS), normal, reticular (R), honeycomb (HC) or ground-glass (GG) features. CALIPER-derived interstitial lung disease (ILD) extent represented the sum of GG, R and HC values. Repeated-measures correlation coefficient (ρrm) and 95% confidence interval (CI) evaluated CALIPER features correlation with PFT. Lin's concordance correlation coefficient (CCC) assessed concordance of CALIPER parameters across different CT dosages.

RESULTS: Twenty patients completed 12 months of follow-up. CALIPER ILD correlated significantly with percent predicted (%) forced vital capacity (FVC) and forced expiratory volume in 1 second (%FEV1; p=0.004, ρrm -0.343, 95% CI [-0.547, -0.108] and 0.008, -0.321, [-0.518, -0.07], respectively). VRS significantly correlated with %FVC and %FEV1 (p=0.000, ρrm -0.491, 95% CI [-0.685, -0.251] and -0.478, 0.000, [-0.653, -0.231], respectively). There was near perfect LD and moderate ULD concordance with standard dose CT for both ILD (CCC 0.995, 95% CI 0.988-0.999 and 0.9, 0.795-0.983, respectively) and VRS (CCC 0.989, 95% CI 0.963-0.997 and 0.915, 0.806-0.956, respectively).

CONCLUSIONS: CALIPER parameters correlate well with PFTs for evaluation of IPF in patients undergoing anti-fibrotic treatment without being influenced by dose variation. CALIPER may serve as a robust, objective adjunct to PFTs in assessing anti-fibrotic treatment related changes.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Koo, Larson, Parris-Skeete, et al. Prospective machine learning CT quantitative evaluation of idiopathic pulmonary fibrosis in patients undergoing anti-fibrotic treatment using low- and ultra-low-dose CT. Clin Radiol. 2021. PMID: 34887070. doi:10.1016/j.crad.2021.11.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。