超高分辨率CT检测人工耳蜗植入术后耳蜗内新骨形成
这项前瞻性单中心横断面研究的二次分析纳入123例植入人工耳蜗至少1年的患者,用超高空间分辨率CT评估耳蜗内新骨形成(NBF)。83例(68%)存在NBF,多位于耳蜗底转,NBF组长期残余听力损失大于无NBF组(22.9 dB vs 8.6 dB,P=0.04)。
要点
- 超高空间分辨率CT可在活体检测人工耳蜗植入术后耳蜗内新骨形成。
- 123例中83例(68%)出现NBF,92%位于最基底10个电极触点周围。
- NBF组长期残余听力损失22.9 dB,大于无NBF组的8.6 dB(P=0.04)。
核心结论
- 超高空间分辨率CT可在活体检测人工耳蜗植入术后新骨形成,多数植入者出现NBF且主要位于耳蜗基底,NBF对长期残余听力保存有不良影响。
研究设计与样本
- 前瞻性单中心横断面研究的二次分析,2016年12月至2018年1月纳入123例植入至少1年的患者,行颞骨超高空间分辨率CT及残余听力评估,两名观察者独立评估NBF。
关键影像表现/征象
- NBF见于83/123例(68%)的466/2706个电极触点(17%),其中428/466(92%)位于最基底10个触点周围,观察者间一致率86%(2297/2683个触点)。
诊断标准与关键数值
- 按共识分为有NBF组(n=83)与无NBF组(n=40);预弯电极组79例中58例有NBF vs 直电极组43例中24例有NBF(P=0.04);耳蜗开窗入路组88例中64例有NBF vs 圆窗入路组34例中18例有NBF(P=0.03)。
临床应用与阅片要点
- 阅片时用超高空间分辨率CT重点观察耳蜗基底最基底10个电极触点周围的新骨形成,并评估电极所在鼓阶位置。
局限性
- 本文为前瞻性单中心横断面研究的二次分析。
- 电极类型与手术入路和NBF相关,但鼓阶位置与NBF无显著关联(P=0.15)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Histopathologic studies reported that cochlear implantation, a well-established means to treat severe-to-profound sensorineural hearing loss, may induce inflammation, fibrosis, and new bone formation (NBF) with possible impact on loss of residual hearing and hearing outcome. Purpose To assess NBF in vivo after cochlear implantation with ultra-high-spatial-resolution (UHSR) CT and its implication on long-term residual hearing outcome. Materials and Methods In a secondary analysis of a prospective single-center cross-sectional study, conducted between December 2016 and January 2018, patients with at least 1 year of cochlear implantation experience underwent temporal bone UHSR CT and residual hearing assessment. Two observers evaluated the presence and location of NBF independently, and tetrachoric correlations were used to assess interobserver reliability. In addition, the scalar location of each electrode was assessed. After consensus agreement, participants were classified into two groups: those with NBF (n = 83) and those without NBF (n = 40). The association between NBF and clinical parameters, including electrode design, surgical approach, and long-term residual hearing loss, was tested using the χ2 and Student t tests. Results A total of 123 participants (mean age ± standard deviation, 63 years ± 13; 63 women) were enrolled. NBF was found in 83 of the 123 participants (68%) at 466 of 2706 electrode contacts (17%). Most NBFs (428 of 466, 92%) were found around the 10 most basal contacts, with an interobserver agreement of 86% (2297 of 2683 contacts). Associations between electrode types and surgical approaches were significant (58 of 79 participants with NBF and a precurved electrode vs 24 of 43 with NBF and a straight electrode, P = .04; 64 of 88 participants with NBF and a cochleostomy approach vs 18 of 34 with NBF and a round window approach, P = .03). NBF was least often seen in full scala tympani insertions, but there was no significant association between scalar position and NBF (P = .15). Long-term residual hearing loss was significantly larger in the group with NBF compared with the group without NBF (mean, 22.9 dB ± 14 vs 8.6 dB ± 18, respectively; P = .04). Conclusion In vivo detection of new bone formation (NBF) after cochlear implantation is possible by using ultra-high-spatial-resolution CT. Most cochlear implant recipients develop NBF, predominately located at the base of the cochlea. NBF adversely affects long-term residual hearing preservation. © RSNA, 2021 An earlier incorrect version appeared online. This article was corrected on December 8, 2021.
引用
- Heutink, Klabbers, Huinck, et al. Ultra-High-Resolution CT to Detect Intracochlear New Bone Formation after Cochlear Implantation. Radiology. 2021. PMID: 34874202. doi:10.1148/radiol.211400
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。