人工智能X线测量技术:腰椎骶骨稳定性相关解剖参数的自动测量
本研究基于1791张腰椎侧位X线片开发深度学习模型,自动测量腰骶前凸角、腰骶角、骶骨水平角和骶骨倾斜角,并与主治医师级放射科医生的手工测量结果比较。模型与参考标准之间呈强相关和一致性(ICC=0.92-0.98,r=0.92-0.97),各参数平均差异为0.09°-0.39°。
要点
- 模型可自动标注四个腰骶解剖参数的关键点并完成测量。
- 模型与参考标准之间ICC为0.92-0.98,r为0.92-0.97。
- 各参数平均差异为0.09°-0.39°,仅腰骶前凸角差异有统计学意义(p=0.02)。
核心结论
- 该模型在准确性方面显示出与主治医师级放射科医生临床等效的测量结果,并在成本效益、可靠性和可重复性方面表现更优;模型可能帮助临床医生从定量角度提高对腰椎疾病和腰背痛的理解与评估。
研究设计与样本
- 基于深度学习的模型开发研究,通过PACS系统收集1791张腰椎侧位X线片用于开发模型,以测试集上手工测量结果为参考标准进行比较。
诊断标准与关键数值
- 模型与参考标准之间的测量性能:腰骶前凸角平均差异0.39°、腰骶角0.09°、骶骨水平角0.13°、骶骨倾斜角0.12°;ICC=0.92-0.98,r=0.92-0.97,MAE=1.35-1.84,RMSE=1.82-2.51;腰骶前凸角差异有统计学意义(p=0.02)。
临床应用与阅片要点
- 模型可自动测量腰骶前凸角、腰骶角、骶骨水平角和骶骨倾斜角,与主治医师级放射科医生手工测量结果呈强相关和一致性;原文指出该模型可能帮助临床医生从定量角度提高对腰椎疾病和腰背痛的理解与评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To develop a deep learning-based model for measuring automatic lumbosacral anatomical parameters from lateral lumbar radiographs and compare its performance to that of attending-level radiologists.
METHODS: A total of 1791 lateral lumbar radiographs were collected through the PACS system and used to develop the deep learning-based model. Landmarks for the four used parameters, including the lumbosacral lordosis angle (LSLA), lumbosacral angle (LSA), sacral horizontal angle (SHA), and sacral inclination angle (SIA), were identified and automatically labeled by the model. At the same time, the measurement results were obtained through landmarks on the test set compared to manual measurements as the reference standard. Statistical analyses of the Percentage of Correct Key Points (PCK), intra-class correlation coefficient (ICC), Pearson correlation coefficient, mean absolute error (MAE), root mean square error (RMSE), and Bland-Altman plots were performed to evaluate the performance of the model.
RESULTS: The mean differences between the reference standard and the model for LSLA, LSA, SHA, and SIA, were 0.39°, 0.09°, 0.13°, and 0.12°, respectively. A strong correlation and consistency between the four parameters were found between the model and reference standard (ICC = 0.92-0.98, r = 0.92-0.97, MAE = 1.35-1.84, RMSE = 1.82-2.51), while with statistically significant difference for LSLA (p = 0.02).
CONCLUSIONS: The presented model revealed clinically equivalent measurements in terms of accuracy, while superior measurements were obtained in terms of cost-effectiveness, reliability, and reproducibility. The model may help clinicians improve their understanding and evaluation of lumbar diseases and LBP from a quantitative perspective in practical work. (ChiCTR2100048250).
引用
- Zhou, Yao, Ma, et al. Artificial intelligence X-ray measurement technology of anatomical parameters related to lumbosacral stability. Eur J Radiol. 2021. PMID: 34864427. doi:10.1016/j.ejrad.2021.110071
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。