仅数字乳腺断层摄影可见而超声隐匿的结构扭曲的病理结果及其与二维乳腺摄影也可见的结构扭曲的比较
回顾性分析1104例数字乳腺断层摄影真空辅助活检中218例结构扭曲,其中113例超声隐匿者按仅DBT可见(35例)与2D及DBT均可见(78例)分组比较病理。仅DBT可见组恶性率34%(12/35)显著高于2D可见组13%(10/78,p<0.05),高危病变率分别为32%(11/35)与22%(17/78,p>0.05)。
要点
- 仅DBT可见的超声隐匿结构扭曲中约三分之一为恶性。
- 仅DBT可见组恶性率34%(12/35)高于2D也可见组13%(10/78),p<0.05。
- 两组高危病变率32%(11/35)与22%(17/78)无显著差异(p>0.05)。
核心结论
- 仅DBT可见的结构扭曲约三分之一为恶性,其恶性率超过2D也可见的结构扭曲;仅DBT可见的结构扭曲中高危病变也占相似比例。
研究设计与样本
- 回顾性审查1104例DBT真空辅助活检记录,识别218例结构扭曲,其中113例超声隐匿且具备完整影像与病理结果(1例临床发现、112例临床隐匿),按仅DBT可见与2D及DBT均可见分组比较恶性率和高危病变率。
关键影像表现/征象
- 113例超声隐匿结构扭曲中35例(31%)为仅DBT可见,78例(69%)为2D及DBT均可见。
- DBT真空辅助活检结果:良性63例(56%)、高危32例(28%)、恶性18例(16%)。
- 4例(12.5%)高危病变经手术升级为恶性。
诊断标准与关键数值
- 最终病理恶性率:仅DBT可见组34%(12/35)vs 2D也可见组13%(10/78),p<0.05。
- 高危病变率:仅DBT可见组32%(11/35)vs 2D也可见组22%(17/78),p>0.05。
临床应用与阅片要点
- 仅DBT可见而超声隐匿的结构扭曲中恶性约占三分之一,报告此类征象时应提示进一步活检评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the rates of malignant and of high-risk lesions among sonographically occult architectural distortions (AD) visible only on digital breast tomosynthesis (DBT) and compare them with AD visible on 2D mammography (2D) and DBT.
METHOD: The records of 1104 DBT-vacuum assisted biopsies (DBT-VAB) were retrospectively reviewed and 218 cases of AD were identified. Complete radiologic examinations and pathologic results were available for 113 sonographically occult AD (1 clinically-detected, 112 clinically-occult). 2D and DBT images were reviewed and AD were divided into a "DBT-detected" group (visible on only DBT) and a "2D-detected" group (visible both in 2D and DBT). The rates of malignant and of high-risk lesions in the "DBT-detected" AD group were calculated and compared to those of the "2D-detected" AD group.
RESULTS: Thirty-five (31%) of 113 AD were assessed as "DBT-detected", while 78 (69%) as "2D-detected". DBT-VAB results were benign lesions in 63 (56%) AD, high-risk lesions in 32 (28%) AD and malignant lesions in 18 (16%) AD. Four (12.5%) high-risk lesions were upgraded to malignancy at surgery. Based on final pathology, the malignancy rate was significantly higher in the "DBT-detected" group than the "2D-detected" group (34% [12/35 cases] vs 13% [10/78]; p < 0.05). The high-risk lesion rates were 32% (11/35 cases) in the "DBT-detected" group and 22% (17/78 cases) in the "2D-detected" group (p > 0.05).
CONCLUSIONS: AD visible on only DBT proved to be malignant in about one third of cases, which exceeded the malignancy rate of AD visible on also 2D. A similar proportion of DBT-only AD was represented by high-risk lesions.
引用
- Linda, Tarricone, Londero, et al. Pathological outcome of sonographically occult architectural distortions (AD) visible only on digital breast tomosynthesis, and comparison with AD visible also on 2D mammography. Eur J Radiol. 2021. PMID: 34864616. doi:10.1016/j.ejrad.2021.110075
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。