文献速递妇产影像泌尿生殖MR

基于MRI的影像组学模型鉴别子宫内膜癌与良性相似病变:多中心研究

MRI-based radiomics model for distinguishing endometrial carcinoma from benign mimics: A multicenter study.
PubMed 文献 · Eur J Radiol · 2021-11-27

本研究回顾性分析多中心术前MRI,在ADC、DWI、T2WI上勾画病灶并提取3142个特征,经卡方检验与二分类LASSO筛选出5个特征,用线性核支持向量机建模。模型在训练集、测试集#1和测试集#2的AUC分别为0.989、0.999和0.961,准确率分别为0.937、0.974和0.908。

要点

  • 模型在中心A设备1训练,在中心A设备2与中心B设备3上验证,AUC分别为0.999与0.961。
  • ADC、DWI、T2WI勾画病灶后提取3142个特征,最终保留5个特征建模。
  • 训练集准确率0.937(精确率0.919、召回率0.963、F1 0.940)。

核心结论

  • 基于MRI的影像组学模型在鉴别子宫内膜癌与良性相似病变方面显示出良好潜力,可能有助于子宫内膜癌的手术管理。

研究设计与样本

  • 回顾性研究,术前MRI按设备与中心分为训练集(中心A设备1,158例)、测试集#1(中心A设备2,78例)和测试集#2(中心B设备3,109例)。
  • 由两名放射科医师在ADC、DWI和T2WI图像上手动勾画肿瘤分割,提取特征后经卡方检验初筛、二分类LASSO回归精选。
  • 采用支持向量机建模,在训练集中用10折交叉验证调参,再在测试集评估;性能指标为AUC、准确率、敏感度、特异度和F1分数。

关键影像表现/征象

  • 从3142个提取特征中选出5个最具信息量的特征。
  • 采用线性核支持向量机构建影像组学模型。

诊断标准与关键数值

  • 训练集AUC 0.989(95%CI 0.968-0.997)。
  • 测试集#1 AUC 0.999(95%CI 0.991-1.000)。
  • 测试集#2 AUC 0.961(95%CI 0.902-0.983)。
  • 训练集准确率0.937(精确率0.919、召回率0.963、F1分数0.940)。
  • 测试集#1准确率0.974(精确率0.949、召回率1.000、F1分数0.974);测试集#2准确率0.908(精确率0.899、召回率0.954、F1分数0.925)。

临床应用与阅片要点

  • 原文结论认为该模型在鉴别子宫内膜癌与良性相似病变方面显示出良好潜力,可能有助于子宫内膜癌的手术管理。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To develop and validate an MRI-based radiomics model for preoperatively distinguishing endometrial carcinoma (EC) with benign mimics in a multicenter setting.

METHODS: Preoperative MRI scans of EC patients were retrospectively reviewed and divided into training set (158 patients from device 1 in center A), test set #1 (78 patients from device 2 in center A) and test set #2 (109 patients from device 3 in center B). Two radiologists performed manual delineation of tumor segmentation on the map of apparent diffusion coefficient (ADC), diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI). The features were extracted and firstly selected using Chi-square test, followed by refining using binary least absolute shrinkage and selection operator (LASSO) regression. The support vector machine (SVM) was employed to build the radiomics model, which is tuned in the training set using 10-fold cross-validation, and then assessed on the test set. Performance of the model was determined by area under the receiver-operating characteristic curve (AUC), accuracy, sensitivity, specificity and F1-score.

RESULTS: Five most informative features are selected from the extracted 3142 features. The SVM with linear kernel was employed to build the radiomics model. The AUCs of the model were 0.989 (95% confidence interval [CI]: 0.968-0.997) for the training set, 0.999 (95% CI: 0.991-1.000) for test set #1, 0.961 (95% CI: 0.902-0.983) for test set #2. Accuracies of the model were 0.937 for the training set (precision: 0.919, recall: 0.963, F1-score: 0.940), 0.974 for test set #1 (precision: 0.949, recall: 1.000, F1-score: 0.974) and 0.908 for test set #2 (precision: 0.899, recall: 0.954, F1-score: 0.925). These results confirmed the efficacy of this model in predicting EC in different centers.

CONCLUSION: The MRI-based radiomics model showed promising potential for distinguishing EC with benign mimics and might be useful for surgical management of EC.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Chen, Wang, Gan, et al. MRI-based radiomics model for distinguishing endometrial carcinoma from benign mimics: A multicenter study. Eur J Radiol. 2021. PMID: 34861530. doi:10.1016/j.ejrad.2021.110072

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。